PE
Figure 10. 480V Three-Phase Wiring Connection
CAUTION
The EVSE should be installed in an area with free-flowing air.
CAUTION
The disconnect switch for each ungrounded conductor of AC
input shall be provided by installation contractor or technician in
accordance with the National Code, ANSI/NFPA 70.
CAUTION
A cord extension set or second cable assembly shall not be used in
addition to the cable assembly for connection of the EV to the EVSE.
DANGER
The lighting flash with arrowhead within a triangle is intended to tell
the user that parts inside the product are risk of shock to person.
NOTE
Read all the instructions before using and installing this product.
NOTE
The capacity of the power supply should be higher than 196kVA for
the EVSE to function correctly.
NOTE
The EVSE should have at least 39.4 inches (1000mm) of clearance
around the product. Follow NEC table 110.26 condition 2, 151-600V.
NOTE
WI-Fi and 3G/4G signal strength should be tested during charger
installation. The RSSI (Received Signal Strength Indication) should
be higher than -65dBm. Poor connection quality might interrupt
charging process or data transmissions.
277V 277V
Neutral
277V
DC EVSE Standalone DC Fast Charger 15
L3
L1
480V
L2