Download Print this page
Dometic BRISK AIR 579 Series Installation Instructions Manual
Dometic BRISK AIR 579 Series Installation Instructions Manual

Dometic BRISK AIR 579 Series Installation Instructions Manual

Advertisement

Quick Links

USA
SERVICE OFFICE
Dometic, LLC
2320 Industrial Parkway
Elkhart, IN 46516
574-294-2511
CANADA
Dometic, LLC
46 Zatonski, Unit 3
Brantford, ON N3T 5L8
CANADA
519-720-9578
ALL INITIAL INSTALLATIONS MUST BE APPROVED BY THE SALES DEPT.
For Service Center
Assistance Call:
800-544-4881
INSTALLATION
INSTRUCTIONS
3107163.176
REVISION
Form No. 3107163.176 5/08
(Replaces 3107163.168)
(French 3108062.146)
©2008 Dometic, LLC
LaGrange, IN 46761
579 Series BRISK AIR
590 Series QUICK COOL
591 Series HEAT PUMP
595 Series QUICK COOL
Roof Top Air Conditioner/Heat Pump
WITH REMOTE ANALOG THERMOSTAT
THIS UNIT IS DESIGNED FOR OEM INSTALLATION
This manual must be read and
understood before installation,
adjustment, service, or mainte-
nance is performed. This unit must
be installed by a qualifi ed service
technician. Modifi cation of this
product can be extremely hazard-
ous and could result in personal
injury or property damage.
57908.321
57908.521
57912.321
57912.531
57912.532
57912.621
57912.622
57912.631
57915.331
57915.336
57915.341
57915.346
Important:
These instructions must stay with
unit. Owner read carefully.
600 Series PENGUIN
USED WITH
Part No. 3107541 and 3107546
Analog Relay Kit
DUCTED
Lire et comprendre ce manuel vant de
procéder à l'installation, à des réglag-
es, de l'entretien ou des réparations.
L'installation de cet appareil doit être
effectuée par un réparateur qualifi é.
Toute modifi cation de cet appareil
peut être extrêmement dangereuse et
entraîner des blessures ou dommages
matériels.
MODELS
57915.421
57915.626
57915.422
57915.631
57915.426
57915.731
57915.521
57915.741
57915.746
57915.522
57915.526
59016.521
57915.531
59016.526
57915.536
59016.621
57915.541
59146.321
57915.546
59146.331
57915.621
59146.521
57915.622
59146.522
RECORD THIS UNIT INFORMATION FOR
FUTURE REFERENCE:
Model Number
Serial Number
Date Purchased
59146.531
59516.606
59530.631
59146.536
59516.631
59530.632
59146.621
59516.731
600312.321
59146.631
59516.736
600312.421
59146.731
59528.601
600315.321
59516.331
59529.531
600315.326
59516.336
59529.601
600315.421
59516.501
59529.631
59516.531
59530.531
59516.536
59530.532
59516.601
59530.536
59516.603
59530.601

Advertisement

loading
Need help?

Need help?

Do you have a question about the BRISK AIR 579 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Dometic BRISK AIR 579 Series

  • Page 1 57915.336 57915.546 59146.331 59516.536 59530.532 REVISION 57915.341 57915.621 59146.521 59516.601 59530.536 Form No. 3107163.176 5/08 57915.346 57915.622 59146.522 59516.603 59530.601 (Replaces 3107163.168) (French 3108062.146) Important: These instructions must stay with ©2008 Dometic, LLC unit. Owner read carefully. LaGrange, IN 46761...
  • Page 2 Analog Ducted Installation Instructions SAFETY INSTRUCTIONS 1. GENERAL INFORMATION A. Product features or specifi cations as described or il- lustrated are subject to change without notice. This manual has safety information and instruc- tions to help users eliminate or reduce the risk B.
  • Page 3 For wire lengths over 24 ft. consult the National Electric Code for proper sizing. Dometic, LLC gives GENERAL guidelines for generator requirements. These guidelines come from experiences people have had in actual applications. When sizing the generator, the total power usage of your recreational vehicle must be considered. Keep in mind generators lose power at high CIRCUIT PROTECTION: Time Delay Fuse or HACR Circuit Breakers Required.
  • Page 4 For wire lengths over 24 ft. consult the National Electric Code for proper sizing. Dometic, LLC gives GENERAL guidelines for generator requirements. These guidelines come from experiences people have had in actual applications. When sizing the generator, the total power usage of your recreational vehicle must be considered. Keep in mind generators lose power at high CIRCUIT PROTECTION: Time Delay Fuse or HACR Circuit Breakers Required.
  • Page 5 AFTER LOCATION HAS BEEN SELECTED: pump installation. a. Check for obstructions in the area where air B. Dometic, LLC will not be liable for any damages or injury conditioner/heat pump will be installed. See incurred due to failure in following these instructions.
  • Page 6 It is the responsibility of the installer of this air conditioner/heat pump system to insure the duct work will not collapse or bend dur- ing and after the installation. Dometic, LLC will not be liable for roof structural or ceiling damage due to improperly insulated, sealed or collapsed duct work.
  • Page 7: Air Distribution System Installation

    5. AIR DISTRIBUTION SYSTEM INSTALLATION A. The Dometic, LLC recommends the basic confi guration shown on page 8, for installing this air conditioner/heat pump system. We have found by testing , that this confi guration works best in most applications of this air conditioner/heat pump system.
  • Page 8 Analog Ducted Installation Instructions C. AIR DISTRIBUTION DUCT INSTALLATION 1. Install the Air Distribution Ducts in the RV Roof Cavity. The Distribution System must meet: a. RV’s requirements. b. System requirements listed in Section 4 on page 6 of this Manual. Terminate the start of the Duct at the back edge of the 14-1/4"...
  • Page 9 Analog Ducted Installation Instructions 6. THERMOSTAT & CABLE INSTALLATION A. LOCATION The proper location of the thermostat is very important to ensure that it will provide a comfortable RV temperature. Ob- serve the following general rules when selecting a location. Locate the thermostat 54"...
  • Page 10 Analog Ducted Installation Instructions 8. INSTALLATION OF COLD CONTROL A. Remove parts package, control box and thermostat from the 3107541.XXX or 3107546.XXX Control Kit carton and identify the mounting for the cold control. See FIGS. 7 & 8 or FIGS. 8A & 8B. B.
  • Page 11 Analog Ducted Installation Instructions 9. WIRING OF CONTROL SYSTEM A. Position the control box (standing up) with the 6 pin connector to the curb side of the vehicle and the service access facing the rear of the vehicle. See FIG. 9. B.
  • Page 12 Analog Ducted Installation Instructions 10. INSTALLATION OF AIR CONDITIONER/HEAT PUMP Installing unit with 3105007.XXX or 3105935.XXX Re- Installing unit with 3308120.XXX Genesis Air Filtration turn Air Cover System Return Air Kit Return Air Cover A. INSTALLATION OF CEILING TEMPLATE A. INSTALLATION OF FOAM DIVIDER Check gasket alignment of the air conditioner/heat Check gasket alignment of the air conditioner/heat pump over the roof opening and adjust if neces-...
  • Page 13 Analog Ducted Installation Instructions Installing unit with 3105007.XXX or 3105935.XXX Re- turn Air Cover - Continued from page 10, column A. Installing unit with 3308120.XXX Genesis Air Filtration 5. Start each mounting bolt through the ceiling tem- System Return Air Kit Return Air Cover - continued plate and up into the unit base pan by hand.
  • Page 14 Analog Ducted Installation Instructions Installing unit with 3308120.XXX Genesis Air Filtration Installing unit with 3105007.XXX or 3105935.XXX Re- System Return Air Kit Return Air Cover - continued turn Air Cover - Continued from page 13, column A. from page 13, column B. 3.
  • Page 15 Analog Ducted Installation Instructions 11. INSTALLATION OF INSIDE DECORATIVE COVER. Installing unit with 3308120.XXX Genesis Air Filtration Installing unit with 3105007.XXX or 3105935.XXX Re- System Return Air Kit Return Air Cover turn Air Cover Install the slider in the return air cover and raise it to the A.
  • Page 16 Analog Ducted Installation Instructions 12. RELAY KIT FIELD WIRING DIAGRAM COOLING/FURNACE COOLING/FURNACE/HEAT STRIP COOLING/FURNACE/ HEAT PUMP...
  • Page 17 Analog Ducted Installation Instructions UNIT FIELD WIRING DIAGRAM AIR CONDITIONERS UNIT FIELD WIRING DIAGRAM HEAT PUMPS...