10�3�5 "Pellet mode" function
Optimal combustion depends on various factors
(installation type, operating and maintenance conditions,
pellet type, etc...)
As a general rule, at the end of combustion, if a lot of
residue remains in the fire pot, it is advisable to edit the
combustion configurations (by increasing the value) until
you achieve the most satisfying solution.
The settable values range from -5 (high quality pellet) to
5 (low quality pellet).
To set the type of pellet being used, press icons
.
100
Fig. 10.13
10�3�6 "Stand-by" function
By enabling this function the appliance reaches the
desired room temperature and then switches off.
If this function is not enabled, the appliance modulates its
operation by not switching off.
To enable this function press "On".
Fig. 10.14
or
Fig. 10.15
Fig. 10.16