Display
Description
motor)
ZAPI 2 fault
45
(AC pump motor
hardware fault)
Handle enable button
46
pressed before
starting
Handle not in the
47
neutral position before
starting
AC pump motor:
49
motor detection fault
AC pump motor
50
contactor fault
Wireless anti-collision
51
alarm
52
Forward valve failure
53
Backward valve fault
54
Lifting valve fault
Lowering switch valve
55
fault
56
Right turn valve fault
57
Left turn valve fault
58
Brake coil fault
60
MCU fault
Fault of MCU current
61
sensor
MCU hardware
62
damaged
63
MCU output fault
64
MCU SRO fault
67
MCU HPD fault
68
Low voltage
High-neutral current
69
fault of MCU
MCU steering input
70
out of range
71
MCU contactor fault
73
MCU overheating
74
MCU fault
MCU pump motor
75
fault
MCU left drive motor
76
fault
MCU right drive motor
77
fault
Service Manual of Scissors Mobile Elevating Work Platform
Machine reaction
No reaction
Disable PCU action
No reaction
No reaction
No reaction
No lifting
No lifting, no walking
No lifting, no walking
No lifting, no walking
No lifting, no walking
No lifting, no walking
No lifting, no walking
No lifting, no walking
No lifting, no walking
No reaction
No reaction
No reaction
No reaction
No reaction
No lifting or high-
speed walking
No lifting, no walking
No lifting, no walking
No lifting, no walking
No reaction
No reaction
No lifting, no walking
No lifting, no walking
No lifting, no walking
Troubleshooting guidance
Replace the motor drive or contact the motor drive
manufacturer
Make sure nothing presses the key on the handle. If so,
consider replacing the handle or PCU.
Confirm that the handle is in the neutral position, check the
neutral position parameter, and if there is no problem, try to
replace the PCU or handle
Replace the motor drive or contact the motor drive
manufacturer
Replace the motor drive or contact the motor drive
manufacturer
The alarm can be cancelled in case of drop
Check the connection of the coil and confirm that there is
no problem. If there is no problem, check whether the coil
itself is short circuited or open circuit.
Check the connection of the coil and confirm that there is
no problem. If there is no problem, check whether the coil
itself is short circuited or open circuit.
Check the connection of the coil and confirm that there is
no problem. If there is no problem, check whether the coil
itself is short circuited or open circuit.
Check the connection of the coil and confirm that there is
no problem. If there is no problem, check whether the coil
itself is short circuited or open circuit.
Check the connection of the coil and confirm that there is
no problem. If there is no problem, check whether the coil
itself is short circuited or open circuit.
Check the connection of the coil and confirm that there is
no problem. If there is no problem, check whether the coil
itself is short circuited or open circuit.
Check the connection of the coil and confirm that there is
no problem. If there is no problem, check whether the coil
itself is short-circuited or open-circuited.
Replace the motor drive or contact the motor drive
manufacturer
Replace the motor drive or contact the motor drive
manufacturer
Replace the motor drive or contact the motor drive
manufacturer
Replace the motor drive or contact the motor drive
manufacturer
Replace the motor drive or contact the motor drive
manufacturer
Replace the motor drive or contact the motor drive
manufacturer
Do charging in time; If the battery power is normal, check
the wiring or replace the ECU.
Replace the motor drive or contact the motor drive
manufacturer
Replace the motor drive or contact the motor drive
manufacturer
Replace the motor drive or contact the motor drive
manufacturer
Replace the motor drive or contact the motor drive
manufacturer
Replace the motor drive or contact the motor drive
manufacturer
Replace the motor drive or contact the motor drive
manufacturer
Replace the motor drive or contact the motor drive
manufacturer
Replace the motor drive or contact the motor drive
manufacturer
154
Need help?
Do you have a question about the S0607II and is the answer not in the manual?
Questions and answers