Deye SUN-30K-SG01HP3 User Manual

Deye SUN-30K-SG01HP3 User Manual

Hybrid inverter

Advertisement

Hybrid Inverter
SUN-29.9K-SG01HP3-EU-BM3
SUN-30K-SG01HP3-EU-BM3
SUN-35K-SG01HP3-EU-BM3
SUN-40K-SG01HP3-EU-BM4
SUN-50K-SG01HP3-EU-BM4
User Manual
R
08/06/2022 15:34:40
Sat
8.30
-3.00
0
30
0
30
KW
ON
KW
0
-2.00
30
0
3.00
30
KW
KW

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SUN-30K-SG01HP3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Deye SUN-30K-SG01HP3

  • Page 1 Hybrid Inverter SUN-29.9K-SG01HP3-EU-BM3 SUN-30K-SG01HP3-EU-BM3 SUN-35K-SG01HP3-EU-BM3 SUN-40K-SG01HP3-EU-BM4 08/06/2022 15:34:40 8.30 -3.00 -2.00 3.00 SUN-50K-SG01HP3-EU-BM4 User Manual...
  • Page 2: Table Of Contents

    Contents 1. Safety Introductions ………………………………………………… 2. Product instructions 02-05 ………………………………………………… 2.1 Product Overview 2.2 Product Size 2.3 Product Features 2.4 Basic System Architecture 2.5 Product handling requirements 3. Installation 05-25 …………………………………………………………… 3.1 Parts list 3.2 Mounting instructions 3.3 Battery connection 3.4 Grid connection and backup load connection 3.5 PV Connection 3.6 CT Connection...
  • Page 3: Safety Introductions

    Documents must be stored carefully and be available at all �mes. Contents may be periodically updated or revised due to product development. The information in this manual is subject to change without notice. The latest manual can be acquired via service@deye.com.cn 1. Safety Introductions Safety signs...
  • Page 4: Product Overview

    2. Product Introductions This is a mul�func�onal inverter, combining func�ons of inverter, solar charger and ba�ery charger to offer uninterrup�ble power support with portable size. Its comprehensive LCD display offers user configurable and easy accessible bu�on opera�on such as ba�ery charging, AC/solar charging, and acceptable input voltage based on different applica�ons.
  • Page 5: Product Size

    2.2 Product Size Inverter Size - 03 -...
  • Page 6: Product Features

    2.3 Product Features - 230V/400V Three phase Pure sine wave inverter. - Self-consump�on and feed-in to the grid. - Auto restart while AC is recovering. - Programmable supply priority for ba�ery or grid. - Programmable mul�ple opera�on modes: On grid, off grid and UPS. - Configurable ba�ery charging current/voltage based on applica�ons by LCD se�ng.
  • Page 7: Product Handling Requirements

    2.5 Product handling requirements Two people stand on both sides of the machine, holding two handles to li� the machine. transport 3. Installation 3.1 Parts List Check the equipment before installa�on. Please make sure nothing is damaged in the package. You should have received the items in the following package: Stainless steel an�-collision Parallel communica�on...
  • Page 8: Mounting Instructions

    Magne�c ring for BMS Stainless steel moun�ng communica�on cable screws M4*12 x2 3.2 Mounting instructions Installation Precaution This Hybrid inverter is designed for outdoor use(IP65), Please make sure the installa�on site meets below condi�ons: · Not in direct sunlight · Not in areas where highly flammable materials are stored. ·...
  • Page 9 ≥500mm ≥500mm For proper air circula�on to dissipate heat, allow a clearance of approx. 50cm to the side and approx. 50cm above and below the unit. And 100cm to the front. Mounting the inverter Remember that this inverter is heavy! Please be careful when li�ing out from the package. Choose the recommend drill head(as shown in below pic) to drill 4 holes on the wall, 62-70mm deep.
  • Page 10: Battery Connection

    3.3 Battery connection For safe opera�on and compliance, a separate DC over-current protector or disconnect device is required between the ba�ery and the inverter. In some applica�ons, switching devices may not be required but over-current protectors are s�ll required. Refer to the typical amperage in the table below for the required fuse or circuit breaker size.
  • Page 11 b) Put on the rubber ring. (as shown in picture 3.4) Pic 3.4 c) crimp terminals. (as shown in picture 3.5) Pic 3.5 d) Fasten terminal with a bolt. (as shown in picture 3.6) Pic 3.6 e) Fasten the terminal with outer cover. (as shown in picture 3.7) Pic 3.7 BMS connec�on Pass the BMS communica�on cable...
  • Page 12 3.3.2 Function port definition Inverter Meter Parallel_1 Parallel_2 BMS1 BMS2 RS485 1 2 3 4 5 6 7 8 9 10 1112 1 2 3 4 5 6 7 8 9 10 1112 SHUT DOWN Meter: for energy meter communica�on. Parallel_1: Parallel communica�on port 1.
  • Page 13: Grid Connection And Backup Load Connection

    3.4 Grid connection and backup load connection · Before connec�ng to the grid, a separate AC breaker must be installed between the inverter and the grid, and also between the backup load and the inverter.This will ensure the inverter can be securely disconnected during maintenance and fully protected from over current. For the 29.9/30/35/40/50kW model, the recommended AC breaker for backup load is 240A.
  • Page 14: Pv Connection

    Be sure that AC power source is disconnected before a�emp�ng to wire it to the unit. 3. Then, insert AC output wires according to polari�es indicated on the terminal block and �ghten terminal. Be sure to connect corresponding N wires and PE wires to related terminals as well. 4.
  • Page 15 3.5.1 PV Module Selection: When selec�ng proper PV modules, please be sure to consider below parameters: 1) Open circuit Voltage (Voc) of PV modules can not exceed max. PV array open circuit voltage of inverter. 2) Open circuit Voltage (Voc) of PV modules should be higher than min. start voltage. 3) The PV modules used to connected to this inverter shall be Class A ra�ng cer�fied according to lEC 61730.
  • Page 16 Safety Hint: Please use approved DC cable for PV system. Cross section(mm ) Cable type Range Recommended value Industry generic PV cable 2.5-4 2.5(12AWG) (model: PV1-F) (12-10AWG) Chart 3-6 The steps to assemble the DC connectors are listed as follows: a) Strip off...
  • Page 17 Please use its own DC power connector from the inverter accessories. Do not interconnect the connectors of different manufacturers.Max. DC input current should be 20A. if exceeds, it may damage the inverter and it is not covered by Deye warranty. - 15 -...
  • Page 18: Ct Connection

    3.6 CT Connection GRID Inverter 1 2 3 4 5 6 7 8 9 10 1112 Black wire White wire Arrow pointing inverter Grid *Note:when the reading of the load power on the LCD is not correct, please reverse the CT arrow. - 16 -...
  • Page 19: Meter Connection

    3.6.1 Meter Connection GRID Inverter Meter Parallel_1 Parallel_2 RS485A Three-Phase Smart Meter RS485B Grid Three-Phase Smart Meter (1,4,7,10) (3,6,9,10) RS 485 CHINT meter CHNT DTSU666 GRID Inverter Meter Parallel_1 Parallel_2 RS485B RS485A 1 2 3 4 5 6 7 8 Eastron Grid (1,2,3,4)
  • Page 20 GRID Inverter Meter Parallel_1 Parallel_2 AC Breaker RS485A RS485B Home Load AC Breaker Three-Phase Smart Meter Grid Blue line White line Blue line White line Blue line Note: the arrow direction towards the inverter White line 6 9 10 13 14 16 17 19 21 (3,6,9,10) Three-Phase Smart Meter...
  • Page 21 GRID Inverter Meter Parallel_1 Parallel_2 AC Breaker Home Load AC Breaker NA LA L1 L2 L3 N Grid S1 S2 S1 S2 S1 S2 Black line Red line Black line Red line Black line Note: the arrow direction Red line towards the inverter 9 1 0 11 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 Eastron...
  • Page 22: Earth Connection(Mandatory)

    Note: When the inverter is in the off-grid state, the N line needs to be connected to the earth. Note: In final installa�on,breaker cer�fied according to IEC 60947-1 and IEC 60947-2 shall be installed with the equipment. 3.7 Earth Connection(mandatory) Ground cable shall be connected to ground plate on grid side, this prevents electric shock if the original protec�ve conductor fails.
  • Page 23: Wiring System For Inverter

    3.9 Wiring System for Inverter - 21 -...
  • Page 24: Wiring Diagram

    3.10 Wiring diagram - 22 -...
  • Page 25 L wire N wire PE wire BMS1 BMS2 Inverter Ground ①DC Breaker ③AC Breaker Battery pack ②AC Breaker Backup Load ④AC Breaker ① DC Breaker for battery Home Load SUN 29.9K-SG-EU: 200A DC breaker SUN 30K-SG-EU: 200A DC breaker SUN 35K-SG-EU: 200A DC breaker SUN 40K-SG-EU: 200A DC breaker SUN 50K-SG-EU: 200A DC breaker ②...
  • Page 26: Typical Application Diagram Of Diesel Generator

    3.11 Typical application diagram of diesel generator L wire N wire PE wire Remotely control signal line coil relay open contact ③AC Breaker Generator GS (diesel generator startup signal) G-start (1,2): dry contact signal for startup the diesel generator. 1 2 3 4 5 6 7 8 9 10 1112 SHUT DOWN BMS1 BMS2...
  • Page 27: Phase Parallel Connection Diagram

    3.12 Three phase parallel connection diagram Note: For the parallel system, the lead-acid ba�ery is not supported. Please use Deye approved lithium ba�ery. L wire N wire PE wire Inverter Meter Parallel_1 Parallel_2 BMS1 BMS2 RS485 No.3 (slave) Ground ①...
  • Page 28: Operation

    4. OPERATION 4.1 Power ON/OFF Once the unit has been properly installed and the ba�eries are connected well, simply press On/Off bu�on(located on the le� side of the case) to turn on the unit. When system without ba�ery connected, but connect with either PV or grid, and ON/OFF bu�on is switched off, LCD will s�ll light up(Display will show OFF), In this condi�on, when switch on ON/OFF bu�on and select NO ba�ery,system can s�ll working.
  • Page 29: Lcd Display Icons

    5. LCD Display Icons 5.1 Main Screen The LCD is touchscreen, below screen shows the overall informa�on of the inverter. 08/06/2022 15:34:40 0.00 -3.00 -2.00 0.00 1.The icon in the center of the home screen indicates that the system is Normal opera�on. If it turns into "comm./F01~F64"...
  • Page 30 5.1.1 LCD operation flow chart Solar Page Solar Graph Grid Page Grid Graph Inverter Page Main Screen Battery Page BMS Page Load Page Load Graph Battery Setting System Work Mode Grid Setting System Setup Gen Port Use Basic Setting Advanced Function Device info - 28 -...
  • Page 31: Solar Power Curve

    5.2 Solar Power Curve Solar This is Solar Panel detail page. ① Solar Panel Genera�on. ② PV1-V: 286V PV1-I: 5.5A PV1-P: 1559W Voltage, Current, Power for each MPPT. ② PV2-V: 286V PV2-I: 5.5A PV2-P: 1559W ③ Daily and total PV produc�on. PV3-V: 286V PV3-I: 5.5A PV3-P: 1559W...
  • Page 32: Curve Page-Solar & Load & Grid

    Li-BMS Mean Voltage:170.0V Charging Voltage :180.0V Batt Total Current:37.00A Discharging Voltage :160.0V Data Mean Temp :23.5C Charging current :30A Total SOC :38% Discharging current :25A Battery 1 Stand by Dump Energy:57Ah Details Data U:170V I:2.04A Li-BMS Power: 101W Charge Volt Curr Temp Energy...
  • Page 33: System Setup Menu

    5.4 System Setup Menu System Setup This is System Setup page. System Work Mode Battery Setting Gen Port Grid Setting Basic Advanced Device Info. Setting Function 5.5 Basic Setup Menu Basic Setting Factory Reset: Reset all parameters of the inverter. Lock out all changes: Enable this menu for se�ng Time Syncs Beep...
  • Page 34: Battery Setup Menu

    5.6 Battery Setup Menu Battery Setting Battery capacity: it shows your ba�ery bank size to Deye hybrid inverter. Batt Mode Use Batt V: Use Ba�ery Voltage for all the se�ngs (V). Lithium Batt Capacity Batt Max. A charge/discharge: Max ba�ery charge/discharge...
  • Page 35 08/06/2022 16:31:10 This page tells the PV and diesel generator power the load and ba�ery. 0.00 -3.00 Signal 0.00 -2.00 0.00 Generator This page tells generator output voltage, frequency, power. And, how much energy is used from generator. Power: 6000W Today=10 KWH Total =10 KWH P_L1: 2KW...
  • Page 36: System Work Mode Setup Menu

    5.7 System Work Mode Setup Menu System Work Mode Work Mode Selling First: This Mode allows hybrid inverter to sell back any excess power produced by the solar panels to 32000 Selling First Max Solar Power the grid. If �me of use is ac�ve, the ba�ery energy also Work Zero Export To Load Solar Sell...
  • Page 37 Time of use: it is used to program when to use grid or generator to charge the ba�ery, and when to discharge the ba�ery to power the load. Only �ck "Time Of Use" Time Of Use then the follow items (Grid, charge, �me, power etc.) Time Power Batt...
  • Page 38: Grid Setup Menu

    5.8 Grid Setup Menu Grid Setting/Grid code selection Grid Mode: General Standard、UL1741 & IEEE1547、CPUC RULE21、 Grid Mode SRD-UL-1741、CEI_0_21_Internal、EN50549_CZ-PPDS(>16A)、 General Standard 0/23 Australia_A、Australia_B、Australia_C、AS4777_NewZealand、 Phase Type Grid Frequency VDE4105、OVE-Direc�ve R25、EN50549_CZ_PPDS_L16A、 50HZ Grid NRS097、G98、G99、EN50549_1_Norway_133V、 Set1 0/120/240 60HZ EN50549_1_Norway_230V、Japan_200VAC_3P3W、 0/240/120 CEI_0_21_External、CEI_0_21_Are�、Japan_400VAC_3P3W、 Japan_415VAC_3P4W、EN50549_1_Switzerland. Please follow the local grid code and then choose the Grid Level LN:220V/LL:380V(AC) corresponding grid standard.
  • Page 39 Grid Setting/F(W) FW: this series inverter is able to adjust inverter output power according to grid frequency. F(W) Droop F: percentage of nominal power per Hz Over frequency Droop F %PE/Hz For example, “Start freq F>50.2Hz, Stop freq F<51.5, Grid Set4 Start freq F Stop freq F...
  • Page 40: Generator Port Use Setup Menu

    5.9 Generator Port Use Setup Menu GEN PORT USE Generator input rated power: allowed Max. power from diesel generator. Mode GEN connect to grid input: connect the diesel generator to the Generator Input GEN connect to Grid input grid input port. PORT Rated Power Smart Load Output: This mode u�lizes the Gen input connec�on...
  • Page 41: Device Info Setup Menu

    Advanced Function Ex_Meter For CT: when using zero-export to CT mode, the hybrid inverter can select EX_Meter For CT func�on Modbus SN Parallel and use the different meters.e.g.CHNT and Eastron. Master Paral. Set3 Slave EX_Meter For CT Meter Select No Meter CHNT Eastron 5.11 Device Info Setup Menu...
  • Page 42: Limitation Of Liability

    Mode III: With Smart-Load AC cable DC cable Solar Backup Load On-Grid Home Load Grid Battery Smart Load Mode IV: AC Couple On-Grid+AC couple AC cable DC cable Solar Backup Load On-Grid Home Load Grid Battery On-Grid Inverter The 1st priority power of the system is always the PV power, then 2nd and 3rd priority power will be the ba�ery bank or grid according to the se�ngs.
  • Page 43 Error code Description Solutions 1,Check the PV input polarity DC_Inversed_Failure 2,Seek help from us, if can not go back to normal state. 1,The BUS voltage can t be built from PV or battery. DC_START_Failure 2,Restart the inverter, If the fault still exists, please contact us for help 1.
  • Page 44 Error code Description Solutions BUS over current. 1, Check the PV input current and battery current setting Tz_HV_Overcurr_fault 2. Restart the system 2~3 times. 3. If the fault still exists, please contact us for help. Remotely shutdown Tz_EmergStop_Fault 1, it tells the inverter is remotely controlled. Leakage current fault 1.
  • Page 45 Error code Description Solutions Grid frequency out of range 1. Check the frequency is in the range of specification or not; AC_OverFreq_Fault 2. Check whether AC cables are firmly and correctly connected; 3. Seek help from us, if can not go back to normal state. Grid frequency out of range 1.
  • Page 46 Under the guidance of our company, customers return our products so that our company can provide service of maintenance or replacement of products of the same value. Customers need to pay the necessary freight and other related costs. Any replacement or repair of the product will cover the remaining warranty period of the product.
  • Page 47: Datasheet

    8. Datasheet SUN-29.9K- SUN-30K- SUN-35K- SUN-40K- SUN-50K- Model SG01HP3- SG01HP3- SG01HP3- SG01HP3- SG01HP3- EU-BM3 EU-BM3 EU-BM3 EU-BM4 EU-BM4 Battery Input Data Ba�ery Type Lithium-ion Ba�ery Voltage Range(V) 160-800 50+50 Max. Charging Current(A) Max. Discharging Current(A) 50+50 Max. Charging/Discharging Power(W) 29900 33000 38500 44000...
  • Page 48 Certifications and Standards IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140, Grid Regula�on UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105 EMC/Safety Regula�on IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 General Data Opera�ng Temperature Range(℃) -40 to +60℃, >45℃ Dera�ng Cooling Intelligent Air Cooling Noise(dB) ≤65 dB Communica�on with BMS Weight(kg) Cabinet size(mm)
  • Page 49 Defini�on of RJ45 Port Pin for Meter Meter-485 Pin 1 2 3 4 5 6 7 8 METER-485_B Meter Port METER-485_A GND_COM METER-485_B METER-485_A GND_COM Defini�on of RJ45 Port Pin for RS485 1 2 3 4 5 6 7 8 RS485 Pin RS485 Port Modbus-485_B...
  • Page 50: Appendix

    · Low Voltage Directive ����/��/EU (LVD) · Restriction of the use of certain hazardous substances ����/��/EU (RoHS) NINGBO DEYE INVERTER TECHNOLOGY CO., LTD. confirms herewith that the products described in this document are in compliance with the fundamental requirements and other relevant provisions of the above mentioned directives.
  • Page 51: Eu Declaration Of Conformity

    Product:Hybrid Inverter Models:SUN-29.9K-SG01HP3-EU-BM3;SUN-30K-SG01HP3-EU-BM3;SUN-35K-SG01HP3-EU-BM3; SUN-40K-SG01HP3-EU-BM4;SUN-50K-SG01HP3-EU-BM4; Name and address of the manufacturer: Ningbo Deye Inverter Technology Co., Ltd. No. 26 South YongJiang Road, Daqi, Beilun, NingBo, China This declaration of conformity is issued under the sole responsibility of the manufacturer. Also this product is under manufacturer’s warranty.
  • Page 52 Add.: No.26 South YongJiang Road, Daqi, Beilun, NingBo, China. Tel.: +86 (0) 574 8622 8957 Fax.: +86 (0) 574 8622 8852 E-mail: service@deye.com.cn Web.: www.deyeinverter.com...