10.16 Floating microswitch
Remove the work top (see above).
Remove the screws which secure the side panel and
remove it (see above).
In the rear section of the base, the sump contains the
pump, the floating microswitch and the float.
Remove the two tubes from their couplings (the red tube
which fills the canister, and the transparent tube through
which water overflow is ducted back to the sump when
the canister is full).
Remove the screw which secures the microswitch sup-
port and insert a screwdriver into the two anchor tabs
which secure it to the sump.
Lift both parts simultaneously and slide the microswitch
support outwards.
Turn the support upside-down to access the floating
microswitch.
- ADL
48/58
599 70 84 17
Need help?
Do you have a question about the ENV06 AEG CRM and is the answer not in the manual?
Questions and answers