1.3 Symbols used Document ID This symbol on the front page of this instruction refers to the Docu- ment ID. By entering the Document ID on www.vega.com you will reach the document download. Information, note, tip: This symbol indicates helpful additional infor- mation and tips for successful work.
During work on and with the device, the required personal protective equipment must always be worn. Appropriate use The VEGABOX 03 is used as breather and terminal housing for sensors with direct cable outlet, such as for example submersible pressure transmitters.
Installations in the US shall comply with the relevant requirements of the National Electrical Code (NEC - NFPA 70) (USA). Installations in Canada shall comply with the relevant requirements of the Canadian Electrical Code (CEC Part I) (Canada). VEGABOX 03 •...
The VEGABOX 03 is available with different housing materials, see chapter "Technical data". 3.2 Principle of operation Application area The VEGABOX 03 is used as breather and terminal housing for sub- mersible pressure transmitters such as for example the VEGAWELL 52. For this purpose the housing contains a filter element for ventila- tion. The VEGABOX 03 is also used as terminal housing for sensors with direct cable outlet such as for example the VEGAPULS WL 61 radar sensor.
3 Product description Fig. 1: Application example 1: Use of a VEGAWELL 52 with VEGABOX 03 Fig. 2: Application example 2: Use of a VEGAPULS WL 61 with VEGABOX 03 Packaging, transport and storage Packaging Your instrument was protected by packaging during transport. Its capacity to handle normal loads during transport is assured by a test based on ISO 4180.
Page 8
Not exposed to corrosive media • Protected against solar radiation • Avoiding mechanical shock and vibration • Storage and transport Storage and transport temperature see chapter "Technical data - temperature Ambient conditions" • Relative moisture 20 … 85 % VEGABOX 03 •...
VEGABOX 03 with any available housing material is suitable for wall mounting. 82 mm (3.23") 10 mm (0.39") Fig. 3: Drilling dimensions for the VEGABOX 03 for wall mounting Carrier rail mounting - The VEGABOX 03 with plastic housing is suitable for direct carrier rail Plastic housing mounting. VEGABOX 03 •...
Page 10
The kit consists of an steel housing adapter plate and four mounting screws M5 x 12. The adapter plate is screwed to the base of the VEGABOX 03 by the user. Fig. 5: VEGABOX 03 with aluminium and stainless steel housing for carrier rail...
Page 11
4 Mounting Fig. 6: VEGABOX 03 for tube mounting 4 screws M5 x 100 Mounting brackets Tube (diameter 1" to 2") VEGABOX 03 •...
If shielded cable is required, connect the cable screen on both ends grounding to ground potential. In the VEGABOX 03, the screen must be con- nected directly to the internal ground terminal. The ground terminal on the outside of the housing must be connected to the potential equalisation (low impedance).
Page 13
9. Connect the shielding to the internal ground terminal, connect the external ground terminal to potential equalisation 10. Tighten the compression nut of the cable entry gland. The seal ring must completely encircle the cable 11. Screw the housing lid back on The connection is finished. VEGABOX 03 •...
Ground terminal for connection of the cable screening Wiring plan - VE- GAWELL 52, 4 … 20 mA, 4 … 20 mA/HART Fig. 9: Wiring plan VEGABOX 03 for VEGAWELL 52, 4 … 20 mA, 4 … 20 mA/ HART To the sensor To voltage supply or processing system...
Page 15
5 Connecting to the sensor Wiring plan - VEGAWELL 52, 4 … 20 mA/HART Pt 100 – Fig. 10: Wiring plan VEGABOX 03 for VEGAWELL 52, 4 … 20 mA/HART Pt 100 To the sensor To voltage supply or processing system Connection lines resistance thermometer Pt 100 Shielding...
Page 16
ABOX 03 Fig. 12: Connection example: Connection of a VEGACONNECT to the VEG- ABOX 03 Sensor Connection cable, sensor - VEGABOX 03 VEGABOX 03 Voltage supply/signal output sensor (depending on the power supply, exter- nal communication resistor > 250 Ω required)
24 hour service hotline Should these measures not be successful, please call in urgent cases the VEGA service hotline under the phone no. +49 1805 858550. The hotline is also available outside normal working hours, seven days a week around the clock.
If personal data is stored on the old device to be disposed of, delete it before disposal. If you have no way to dispose of the old instrument properly, please contact us concerning return and disposal. VEGABOX 03 •...
DIN EN ISO 14001. Help us to meet these requirements and observe the environmental instructions in the chapters "Packaging, transport and storage", "Dis- posal" of this instructions manual. VEGABOX 03 •...
4 g at 5 … 200 Hz according to EN 60068-2-6 (vibration with resonance) Vibration resistance with carrier rail 1 g at 5 … 200 Hz according to EN 60068-2-6 (vibration mounting with resonance) Shock resistance 100 g, 6 ms according to EN 60068-2-27 (mechanical shock) VEGABOX 03 •...
Page 22
Operating voltage see operating instructions manual of the respective sensor Electrical protective measures Protection rating Ʋ Plastic housing IP66/IP67 nach IEC 60529, NEMA Type 4X Ʋ Housing Aluminium, stainless steel IP66/IP68 (0.2 bar) acc. to IEC 60529, NEMA Type 6P VEGABOX 03 •...
10.2 Dimensions VEGABOX 03, plastic housing ø 79 mm ~ 69 mm (3.11") (2.72") 97 mm (3.82") Fig. 13: VEGABOX 03 with plastic housing VEGABOX 03, aluminium housing ø 86 mm ~ 75,2 mm (3.39") (2.95") 97 mm (3.82") Fig. 14: VEGABOX 03 with Aluminium housing...
Page 24
~ 75 mm (3.39") (2.95") 97 mm (3.82") Fig. 15: VEGABOX 03 with stainless steel, precision cast housing Mounting elements 97 mm (3.82") 82 mm 7 mm (3.23") (0.28") Fig. 16: Adapter plate for carrier rail mounting of VEGABOX 03 VEGABOX 03 •...
Page 25
10 Supplement 48...84 mm (1.89"...3.31") 20 mm 20 mm (0.79") (0.79") Fig. 17: Brackets for tube mounting of VEGABOX 03 VEGABOX 03 •...
Les lignes de produits VEGA sont globalement protégées par des droits de propriété intellec- tuelle. Pour plus d'informations, on pourra se référer au site www.vega.com. VEGA lineas de productos están protegidas por los derechos en el campo de la propiedad indus- trial. Para mayor información revise la pagina web www.vega.com.