T R O U B L E S H O O T I N G 
5.3.3  Machine blocked ­ call service center 
For fault localization, check first which buttons of the coffee/capuccino units 
turn to red in combination with this error message. 
Possible reasons: 
• 
Defective NTC temperature sensor on thermoblock 
• 
NTC temperature sensor is not fixed 
• 
Thermoblock defective 
• 
Flow meter defective 
• 
Micro switch of safety lid defective 
• 
Motor of extraction unit blocked or defective 
Remedy: 
• 
Check the history bit counters in the statistic data file (refer to Service Stick manual). 
Every problem that leads to a "machine blocked" message is tracked and 
monitored by history bits. For each history bit, two counters are in use: one 
which cannot be reset, and a resetable one. 
Example of history bit counters (excerpt) 
075; ­­­­­ History Bit counters ­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ 
076; NTC short (left side);0 
077; NTC disconnected (left side);0 
078; brew unit can't reach a position (left side);0 
079; not possible to initialize the brew unit (left side);0 
080; Brew unit door switch (left side);0 
081; flowmetertimeout (left side);0 
082; flowmetertimeout by rinsing (left side);0 
083; heating up error by coldstart (left side);0 
084; Capsule was not possible to throw off (left side);0 
085; Decalc Alert Level 2 (left side);0 
086; NTC short (right side);0 
087; NTC disconnected (right side);0 
088; brew unit can't reach a position (right side);0 
089; not possible to initialize the brew unit (right side);0 
090; Brew unit door switch (right side);0 
091; flowmetertimeout (right side);0 
092; flowmetertimeout by rinsing (right side);0 
093; heating up error by coldstart (right side);0 
094; Capsule was not possible to throw off (right side);0 
095; Decalc Alert Level 2 (rigth side);0 
096; NTC short (middle);0 
097; NTC disconnected (middle);0 
098; heating up error by coldstart (middle);0 
099; Decalc Alert Level 2 (middle);0 
100; descaling aborted;0 
101; Direct water problem;0 