Manual version: 2.1.1
Product code: P2005A
Product Version: 2.0
Firmware Version: 2.6
Software Version: 2.0

Advertisement

loading

Summary of Contents for Ossila X200

  • Page 1 Manual version: 2.1.1 Product code: P2005A Product Version: 2.0 Firmware Version: 2.6 Software Version: 2.0...
  • Page 2 Tool Bar ..................................17 Front Panel ................................18 Data Plots................................... 20 Data Logging ................................22 IV Measurement ................................ 24 Menu Bar ................................... 26 Advanced Measurements ..........................27 10. Troubleshooting ..............................28 11. Related Products............................... 29 www.ossila.com Ossila Limited © 2024...
  • Page 3 Telephone number: +31 (0)718 081020 Email Address: info@ossila.com declare that the DoC is issued under our sole responsibility and belongs to the following product: Product: Source Measure Unit – X200 (P2005A2) Serial number: P2005A2- xxxx Object of declaration: Source Measure Unit – X200 (P2005A2)
  • Page 4 Декларация за съответствие на ЕС Производител: Ossila BV, Biopartner 3 building, Galileiweg 8, 2333 BD Leiden, NL. Декларира с цялата си отговорност, че посоченото оборудване съответства на приложимото законодателство на ЕС за хармонизиране, посочено на предходната(-ите) страница(-и) на настоящия документ.
  • Page 5 User Manual [Magyar] EU-s megfelelőségi nyilatkozat Gyártó: Ossila BV, Biopartner 3 building, Galileiweg 8, 2333 BD Leiden, NL. Kizárólagos felelösségünk mellett kijelentjük, hogy a felsorolt eszköz megfelel az ezen dokumentum előző oldalán/oldalain található EU-s összehangolt jogszabályok vonatkozó rendelkezéseinek. [Nederlands] EU-Conformiteitsverklaring Fabrikant: Ossila BV, Biopartner 3 building, Galileiweg 8, 2333 BD Leiden, NL.
  • Page 6 The absolute maximum input voltage for the Vsense channels is ±12 V. Do NOT apply • input while not powered. Use of Equipment The Ossila Source Measure Unit is designed to be used as instructed. It is intended for use under the following conditions: Indoors in a laboratory environment (Pollution Degree 2). •...
  • Page 7 Source Measure Unit User Manual Servicing If servicing is required, please return the unit to Ossila Ltd. The warranty will be invalidated if: Modification or service has been carried out by anyone other than an Ossila engineer. • The Unit has been subjected to chemical damage through improper use.
  • Page 8 User Manual Requirements The Ossila SMU is compatible with our Front Panel software which is included with the system. It allows for simple operation of the SMU and precision voltmeter channels. Table 3.1 details the minimum computer specifications for the Ossila SMU Front Panel software.
  • Page 9 Source Measure Unit User Manual Specifications The Ossila Source Measure Unit contains four channels: two source measure units (SMUs) and two precision voltmeters. There is also a general-purpose shutter/trigger to allow other instruments to be controlled or control the unit.
  • Page 10 5.2.2 Measurement Speed The Ossila Source Measure Unit utilises a high-speed, 24-bit no Latency ∆Σ™ ADC. It provides ten speed/ resolution combinations (6.9 Hz/200 nV RMS noise to 3.5 kHz/25 µV RMS noise) which can be selected, with no latency between conversion results.
  • Page 11 5.2.4 Current Measurement Specifications The current measurement of the Ossila Source Measure Unit is spread over 5 ranges. Each range has a different maximum current, accuracy, and resolution. As the range number increases, the maximum measurable current decreases, but the accuracy and resolution increase.
  • Page 12 50 µV 10 µV Measurement Non-Linearity The non-linearity in the measurement of the Ossila Source Measure Unit is kept well below the measurement accuracy of every range. Such non-linearity is common due to different amplification stages and analogue digital conversion processes.
  • Page 13 Shutter/ Trigger is 5 volts and can source and sink up to 30 mA of current; higher currents may result in damage to the unit. Physical Specifications Table 5.6. Ossila Source Measure Unit physical specifications. Channels 2 x source measure units (SMUs)
  • Page 14 Source Measure Unit User Manual System Components The Ossila Source Measure Unit is comprised of the Ossila Source Measure Unit (Figure 6.1) and the Ossila SMU Front Panel Software (Figure 6.2). Figure 6.1. The Ossila Source Measure Unit. Figure 6.2. The Ossila SMU Front Panel software.
  • Page 15 Figure 7.1. Ossila Source Measure unit in the Device Manager. Connecting to a Network The Ossila Source Measure Unit is designed to work with any network that supports DHCP. When the ethernet cable is plugged in, the unit will automatically detect and identify the network and register itself within a few seconds.
  • Page 16 1. Run the file ‘Ossila-SMU-Front-Panel-Installer-vX-X-X-X.exe’ on the USB memory stick provided. 2. Follow the on-screen instructions to install the software. Note: The Ossila SMU Front Panel software and Source Measure Unit USB drivers can also be downloaded from www.ossila.com/pages/software-drivers www.ossila.com...
  • Page 17 Source Measure Unit User Manual SMU Front Panel Software 1. Start the Ossila SMU Front Panel software and the window shown in Figure 6.2 will open. 2. There are 6 main areas of the UI, which are detailed below: Tool Bar II.
  • Page 18 Unit: SMU 1, SMU 2, Vsense 1, and Vsense 2. Figure 8.3. Control and output panel for the SMU channels. Each SMU panel contains an on/off toggle button, voltage (left) and current (right) measurement displays, and the settings, which are detailed below. www.ossila.com Ossila Limited © 2024...
  • Page 19 The number of samples to take for each data point (the OSR, see Section 5.2.2 for details). A higher sampling rate will increase the accuracy of a measurement but will increase the time taken for it to be performed. www.ossila.com Ossila Limited © 2024...
  • Page 20 SMU data are displayed in the plots, and controls for Output Voltage and Current Range as described in Section 8.2. Vsense panels contain an on/off toggle, a legend line, and a switch for toggling Vsense data display. www.ossila.com Ossila Limited © 2024...
  • Page 21 ‘A’ button in the bottom-left of the plot, as shown in Figure 8.8 (note, this button will only appear whilst the mouse cursor is over the plots). Figure 8.8. Button to reset the plot axes. www.ossila.com Ossila Limited © 2024...
  • Page 22 Save the data in the table to a CSV (comma delimited) (.csv) or text (tab delimited) (.txt) file. A file dialog will open to allow you to select a save file name and location. Clear all data from the table. A confirmation dialog box will be displayed. www.ossila.com Ossila Limited © 2024...
  • Page 23 Select at least one row in each row to be deleted, then either: Right-click on the highlighted cells and select ‘Delete’ from the menu. • Press the delete keyboard shortcut (Delete on Windows). • A confirmation dialog will appear before any data is deleted. www.ossila.com Ossila Limited © 2024...
  • Page 24 The voltage in volts at which to end the measurement. Voltage Step The step size in volts for changing the voltage during the measurement. Voltage Settle Time The time in seconds between outputting a new voltage and measuring the current. www.ossila.com Ossila Limited © 2024...
  • Page 25 Select an IV measurement to change the label of. Select IV measurements to delete. Figure 8.11. IV measurement selection window. 8.5.1 Plot Display Controls The IV Measurement plot has the same controls as detailed in Section 8.3. www.ossila.com Ossila Limited © 2024...
  • Page 26 Exit Close the software. 8.6.2 View Toggle Theme Switch the software between light and dark themes. Figure 8.13. SMU Front Panel in light theme. www.ossila.com Ossila Limited © 2024...
  • Page 27 If you want to perform a measurement that is not covered by the Front Panel software, you can control the Source Measure Unit directly using a variety of programming languages. More information and the available commands can be found in the Programming Documentation: downloads.ossila.com/manuals/source-measure-unit-programming-documentation.pdf www.ossila.com Ossila Limited © 2024...
  • Page 28 User Manual 10. Troubleshooting Most of the issues that may arise will be detailed here. However, if you encounter any issues that are not detailed here, then contact us by email at info@ossila.com. We will respond as soon as possible. Problem...
  • Page 29 For fast and secure electrical solution for performing current- connections, this product makes PV voltage-luminance characterisation and OLED device testing easy. of LEDs. Product code: T2004 / T2005 Product code: P2008A1 / P2011A1 / P2012A1 www.ossila.com Ossila Limited © 2024...