By means of the button rotation procedure the factory settings of the transmitter can be changed from:
<
>
➢ "
" and "
" selection
➢ " Λ " and " V " activation control
to
➢ " Λ " and " V " selection
<
>
➢ "
" and "
" activation control
The first configuration is suitable for systems where the motion is vertical (roller blinds, soft shade curtains
etc.) while the second is suitable for systems whose motion is horizontal (draped curtains, vertical, etc.).
1. Press button " Setting " until LED LD flashes 5 times followed by 3 quick flashes;
2. Press button " Limit "
3. 6 flashes of the LED LD confirm that the button rotation procedure has been successful).
This procedure allows to set the limit stops in the enabled digital systems.
1. Press button " Limit " until LED LD flashes 5 times followed by 3 quick flashes;
2. Select the system to which set the limit stops (the associated LED must be on);
–
3. Press the "
" button to activate the limit stops setting.
4. Refer to the instructions for setting the limit stops relative to the digital motor. During the limit stops
adjustment the buttons of transmitter have the following functions:
" Λ "
" V "
<
"
>
"
-
"
5. The LED LD0 flashes quickly 5 times to confirm the set has been successful. The transmitter closes the
procedure;
6. Repeat from point 1) for a new limit stops setting.
Note:
•
If the limit switches are set overlap, the corresponding LED flashes 11 times.
This procedure cancels all the settings in the transmitter memory returning it to the factory settings.
1. Press simultaneously the " Setting " and " Limit " buttons until LED LD flashes 5 times followed by 3
quick flashes;
2. Six flashes of the all LED LD confirm that the procedure has been successful.
If intermediate stopping points are set in systems controlled by transmitters Ref. 5474 and Ref. 5484,
when a brief impulse is sent the systems activated will reach the first stopping point in sequence.
To open or close completely the control must be held down for 4 sec.
Button rotation
Setting Limit Stops
moves the system in Direction 1
moves the system in Direction 2
moves the system with a step in Direction 1
"
moves the system with a step in Direction 2
"
"
memorizes the position of the limit stop
Intermediate limit stops
The LED LD0 starts flashing;
Reset
En 4
Z803 rB
11