ERROR CODES
• E01: There is a problem with the BMS, MeterBoost should be contacted.
• E02: The battery is ON, but the system is not detecting voltage on the out-
put terminals. Probably the internal fuse is blown, and the battery must be
sent to MeterBoost to be serviced.
• E03: Mismatch between the battery PCB and BMS.
• E04: The user tried to turn ON a battery that is not paired to a MtB GateWay
and the battery detected voltage in its output. The battery should first be
paired with a MtB GateWay and then turned on.
• E05: Battery PCB lost communication with the BMS.
• E06: The battery could not verify or change the BMS status. The battery
output state is undefined, there could be voltage at the battery output
terminals.