Technical manual for the Skycom Solo microprocessor Issue 2 – 05/12/2023 - Last technical change 06/07/2010 WE RESERVE THE RIGHT TO ALTER WITHOUT GIVING PRIOR NOTICE TECHNICAL DATA, DIMENSIONS AND WEIGHTS DESCRIBED IN THIS MANUAL...
International Lift Equipment Ltd : Skycom Solo Manual Page 2 REF: ILE-RD-SM-03 06/07/2010 Contents Introduction ............................. 3 EcoMode ........................... 3 Instructions ..........................4 TEST operation for the first time ...................... 5 The Hardware ..........................7 Solo Processor Module ......................7 IO Module ..........................
REF: ILE-RD-SM-03 06/07/2010 Introduction The manual gives details on the skycom Solo lift controller, detailing the hardware that goes to make up the controller along with instructions for the setup of the lift. The modular system allows variable lift configurations.
International Lift Equipment Ltd : Skycom Solo Manual Page 4 REF: ILE-RD-SM-03 06/07/2010 Instructions The instruction for the procedure detailed in this guide to get the lift system running correctly, are laid out as follows: The instructions can be divided into 3 stages:...
International Lift Equipment Ltd : Skycom Solo Manual Page 5 REF: ILE-RD-SM-03 06/07/2010 TEST operation for the first time The following set of instructions detail how to get the lift running in test operation for the first time. If you have any problems then please refer to the fault finding section of this manual.
Page 6
International Lift Equipment Ltd : Skycom Solo Manual Page 6 REF: ILE-RD-SM-03 06/07/2010 Yes/ Condition/Action/Question Notes Condition: The checks above have all been carried out and the lift has been switched on. Action: Check the incoming three phase sequence is correct (PFRR relay is energised).
All cards are mounted in an individual module that is DIN rail mounted. Each module plugs into the adjoining modules to provide bus connections. Solo Processor Module The Skycom Solo processor module has the following features: USB serial connection to PC •...
International Lift Equipment Ltd : Skycom Solo Manual Page 8 REF: ILE-RD-SM-03 06/07/2010 Relay Module The Relay module has the following features: 4 Relay outputs (N/O) • 2 Relay outputs (N/O or N/C user selectable via wiring) • Thermal monitoring •...
International Lift Equipment Ltd : Skycom Solo Manual Page 9 REF: ILE-RD-SM-03 06/07/2010 Handheld The Handheld module has a 128x64 pixel resolution LCD screen, with a 6 button keypad interface to enable easy configuration and modification of parameters. The LCD screen has a backlight timeout, the handheld also has an energy efficient switch mode power supply and any non active hardware components are intelligently powered down when not being used.
Page 10 REF: ILE-RD-SM-03 06/07/2010 Menu System The main menu is accessed by pressing the ENT key from the ILE splash screen. This will present you with a screen giving the following options: Operating Mode If you select ‘No password View Mode’ then you will be able...
• For a full list of the parameters and their constraints please see appendix A of this manual or contact ILE for assistance. For information on the functionality that the parameters provide see the Parameters Section of this manual. If you want to see what inputs are on then you can use the label on the inside of the door of the controller to match up the relevant LED to the relevant I/O, or you can use the I/O viewer as follows.
[STR [RSD Lift Viewer Lift=NORMAL │ ├ The Lift Viewer is the heart of the Skycom Solo handheld, this Motion= │ ├ screen gives a lot of information about the status of the lift. It Doors= CLOSED │ 6 ├...
International Lift Equipment Ltd : Skycom Solo Manual Page 13 REF: ILE-RD-SM-03 06/07/2010 Parameters Job & System The first 4 parameters, Job Number, Solo Version Number, Customer Name, and Site Name all provide information about the lift installation. Collective Type details the way in which the calls are collected.
International Lift Equipment Ltd : Skycom Solo Manual Page 14 REF: ILE-RD-SM-03 06/07/2010 Reverse Time dictates the earliest amount of time after the close relay has been dropped that the open relay can be activated and vice versa. Car Preference Time is used only when the APB collective parameter has been set, landing calls are inhibited while this timer is still running.
International Lift Equipment Ltd : Skycom Solo Manual Page 15 REF: ILE-RD-SM-03 06/07/2010 Daylight Saving automatically adjusts the real time clock according to GMT. Pre Flite Checking dictates whether a check is made of the acknowledge feedback once the locks are made before a travel will commence.
International Lift Equipment Ltd : Skycom Solo Manual Page 16 REF: ILE-RD-SM-03 06/07/2010 Start Delay Time is the time by which the start will be delayed. Enable Time is the amount of time, after the lift has stopped, before the enable output is dropped.
International Lift Equipment Ltd : Skycom Solo Manual Page 17 REF: ILE-RD-SM-03 06/07/2010 ERET 1-7 There are 7 emergency return profiles that are fully configurable using the following set of parameters. Name is the name of the profile. Drop off Floor this is the floor at which passengers, in the lift when the eret input is seen, will be dropped off at.
International Lift Equipment Ltd : Skycom Solo Manual Page 18 REF: ILE-RD-SM-03 06/07/2010 APPENDIX A – Parameter List Job & System Password Name Type Default Step Level Job Number xxxx Solo Version Number Customer Name Site Name Full Collective Type...
Page 19
International Lift Equipment Ltd : Skycom Solo Manual Page 19 REF: ILE-RD-SM-03 06/07/2010 Password Name Type Default Step Level Reverse Time 1000 Car Preference Time CC Drop Time 3000 Lock Time 3000 1000 DOP Held Time SE Held Time DLR Held Time...
Page 20
International Lift Equipment Ltd : Skycom Solo Manual Page 20 REF: ILE-RD-SM-03 06/07/2010 General Password Name Type Default Step Level No of Self Test Self Test Top Floor Self Test Bot Floor Man Gate Late Cancel Yes/No LISI Indicator Yes/No...
Page 21
International Lift Equipment Ltd : Skycom Solo Manual Page 21 REF: ILE-RD-SM-03 06/07/2010 Homing Password Name Type Default Step Level Homing Time 1200 Homing Floor Travel Password Name Type Default Step Level Low Speed Prot Time Start Fail Time Stop Time...
Page 22
International Lift Equipment Ltd : Skycom Solo Manual Page 22 REF: ILE-RD-SM-03 06/07/2010 OSI Indication Password Name Type Default Step Level Error In Position Yes/No Double Journey Time Yes/No Hydraulic Overtravel Yes/No Start Failure Yes/No Relevel Error Yes/No Open Prot Fault...
Page 23
International Lift Equipment Ltd : Skycom Solo Manual Page 23 REF: ILE-RD-SM-03 06/07/2010 ERET 1-7 Password Name Type Default Step Level Name Drop off Floor Return Floor Alt Return Floor Const Pres Open Yes/No Const Pres Close Yes/No Park Open...
Page 24
International Lift Equipment Ltd : Skycom Solo Manual Page 24 REF: ILE-RD-SM-03 06/07/2010 Time & Date Password Name Type Default Step Level Year Month Hour Minute London Tel: 0208 527 9669 Leicester Tel: 0116 269 0900 London Fax: 0208 527 0936 Leicester Fax: 0116 269 0939 Website: www.ilegroup.co.uk...
International Lift Equipment Ltd : Skycom Solo Manual Page 25 REF: ILE-RD-SM-03 06/07/2010 APPENDIX B – Speech List THIS LIFT IS OVERLOADED SEVENTEEN THIS LIFT IS UNDER MAINTENANCE CONTROL EIGHTEEN THIS LIFT IS OUT OF SERVICE NINETEEN THIS LIFT IS UNDER FIRE CONTROL OPERATION...
International Lift Equipment Ltd : Skycom Solo Manual Page 26 REF: ILE-RD-SM-03 06/07/2010 APPENDIX C – Event List EMERGENCY STOP The live voltage feed to input EMER was removed LAN LOCK TIP HIGH SPD The live voltage feed to input LANL was removed on high speed...
Page 27
International Lift Equipment Ltd : Skycom Solo Manual Page 27 REF: ILE-RD-SM-03 06/07/2010 DOOR OPEN PUSH HELD Door open push held, all calls cancelled SAFE EDGE HELD Safe edge held all calls cancelled DETECTOR EDGE HELD Detector edge held, check door light ray...
International Lift Equipment Ltd : Skycom Solo Manual Page 28 REF: ILE-RD-SM-03 06/07/2010 APPENDIX D – INPUT LIST ERET1 ERET2 ERET3 ERET4 ERET5 ERET6 ERET7 ERET8 LW90 LW110 SERV FIRE THERM EMER CARL LANL TEST T OPEN T CLOSE T UP...
International Lift Equipment Ltd : Skycom Solo Manual Page 29 REF: ILE-RD-SM-03 06/07/2010 APPENDIX E – OUTPUT LIST HLRU NUDGE STOP STAR DELTA FIRE I LW90 I LW110 I HLU1 HLU2 HLU3 HLU4 HLU5 HLU6 HLU7 HLD2 HLD3 HLD4 HLD5...
Need help?
Do you have a question about the Skycom Solo and is the answer not in the manual?
Questions and answers