SH230CONTROL UNIT
FOR SHUTTERS
SH230
cod
.
APE-528/0230
Instructions for assembly and use
TECHNICAL FEATURES
Before installing the product, be sure to disconnect the power supply. See the table
opposite for product characteristics:
PROGRAMMING OPERATION TIME
With the damper closed, set microswitch DIP2 to ON, DIP1 to OFF and DIP5/DIP6 to
ON. Enter programming by pressing the external button (connected between DIP9
and 10) or a previously inserted transmitter. A beep and blink will indicate the start
of programming, and the door will open until it reaches its end stop. Once reached
transmit the close command by pressing the external button or a transmitter. The
door will reach its closing limit and two beeps accompanied by a ashing will indica-
te the end of programming. Reposition the dips to the previous position.
PROGRAMMING AUTOMATIC CLOSING TIME
Programming can be done only with the door at rest and with DIP1 and DIP2
microswitches set to ON. Press the external button or inserted transmitter button; a
beep and a ash will indicate the start of programming. Finish by pressing the
button in question again after the desired time; Two beeps accompanied by a
ashing will con rm successful programming. Reposition the dips to the previous
position.
STANDARD RADIO CONTROL
COMPATIBILITY TABLE
SETTING OPTIONS
DIP1: Timer/Auto closing selector:
· ON - automatic closing with timer.
· OFF - automatic closing disabled.
DIP2: Programming timer:
· ON - programming operation time (DIP1 OFF).
Programming closing time (DIP1 ON).
· OFF - programming time disabled.
1 2 3 4 5 6
The technical characteristics can be subject to variations without advance notice. AB Tecno S.r.l. doesn't take responsibilities for damages caused by the improper use of the device.
brand
model
CAME
TOP 433EE
ENTREMATIC
ZEN
ABEXO
EGO 433
DITEC
BIXLS2
TELCOMA
TANGO 4SW
PUJOL
VARIO
LUTEC
HT12E
SUPERLIFT
N3588
NICE
FLO
BFT
MITTO433
JCM
NEO10
Power supply
Motor power
Fuse
Run time
Closing time
Code combinations
Number of codes
Programming of codes
Function selection
Frequency
Approval
Sensitivity
Application range
Antenna
Operating temperature
HCS RADIO CONTROL
COMPATIBILITY TABLE
brand
model
GIBIDI
AU03000 - AU03010 - AU01600
APRIMATIC
TM4
ACM
TX2 COLOR
DIP3: Radio programming:
· ON - radio programming new transmitters enabled
· OFF - radio programming disabled
:
DIP4: Man Present (with jumper J2 closed hold down the transmitter Close button):
· ON - to realize the close, the transmitter button or external button must be held down. If
not held down, the operation stops.
· OFF - normal operation.
DIP5-6: Disable/Enable photocell and wire or resistive border:
DIP5
DIP6
ON
ON
Photocell and border disabled (BY DEFAULT))
ON
OFF
Flush photocell and border enabled
Photocell and resistive border enabled.
OFF
ON
Photocell enabled border disabled.
OFF
OFF
By default, with jumper J2 open, the control unit is stepping, so pressing the single button
during opening or closing stops the door. Pressing it again will resume the reverse direction
from the previous direction. With jumper J2 closed, the transmitter will instead operate with
three buttons. (Open-Stop-Close). Recommended option for DEADMAN.
Via Cicogna 95 - 40068 San Lazzaro di Savena (BO)
Tel: +39 051 6259580 - fax: +39 051 6259600
info@abtecno.com - www.abexo.tech
ABEXO is a registered trademark
property of AB Tecno Srl
230V ac +-10%
1HP (1350 W)
6,3 A
Default 25 sec, programmable up to 2.5 minutes
Default 20 sec, programmable up to 3 minutes
72 million codes
50
Self-learning
Stores code function
433.92 Mhz
2014/35/UE ,2014/30/UE,2014/53/EU
Greater than -100 dBm
Standard 50m / man present 10m
Built-in
Da -10ºC a 70ºC
AB Tecno Srl