Download Print this page

Advertisement

Quick Links

BEFORE YOU BEGIN...
WARNING
This bed must be securely anchored to the
wall or floor. Failure to follow instructions
may cause the bed and cabinet to tip over,
which could cause serious injury.
NOTICE: It takes two people to safely assemble
the system - do not try to do it by yourself.
Please read and understand the instructions before
you start to assemble.
If you have any problems when installing,
contact SICO Customer Service at
1-800-328-6138
Printed in the USA (02-05)
SICO is a registered trademark and EUROBED
(MODEL No. 4182, 5682, 6387)
and 24/7 EUROBED
(Model No. 5690T, 5695T, 6395T)
Tools Required
- Phillips and flat blade screwdrivers
- Electric drill, 1/4" or 3/8"
- Drill bits: 1/8"; 3/16"; 1-3/8" (not required if using SICO
recess). A 1" bit may also be required (see page 9).
- Rotary hammer drill (if attaching to floor)
- Masonry bit (if attaching to masonry floor or wall); size of
bit depends on floor type - refer to pages 8-10
- Screw-anchor setting tool (if attaching to soft concrete
floor)
- Carpenter's Level
- Tape Measure
- Stud finder (preferably an electronic type)
- Hammer
- Ratchet wrench, 9/16" standard and 3/4" deep socket.
®
is a trademark of SICO Incorporated
EUROBED
®
®
INSTALLATION
INSTRUCTIONS
Part No. 104595 Rev F

Advertisement

loading
Need help?

Need help?

Do you have a question about the EUROBED 4182 and is the answer not in the manual?

Questions and answers

Summary of Contents for SICO EUROBED 4182

  • Page 1 - Phillips and flat blade screwdrivers WARNING - Electric drill, 1/4” or 3/8” - Drill bits: 1/8”; 3/16”; 1-3/8” (not required if using SICO This bed must be securely anchored to the recess). A 1” bit may also be required (see page 9).
  • Page 4 Use the SICO wall-mounting serious injury could result. fixture provided with the bed. If your wall construction is such that the system cannot or should not be attached to the wall (see step 1 on page 9), follow the floor mounting instructions on page 9 through 12 instead.
  • Page 5: General Information

    IMPORTANT: Before you start If anything is missing or if Right to install the bed, verify the size you have any questions at Hand Side of opening required: ® installation, contact SICO Customer Service at Opening Opening Opening Height Height 1-800-238-6138.
  • Page 6 Hold the fixture flush with The wood screws (Part No. the top and back edges of 103745) supplied for attaching the the verticals, then push it SICO wall-mounting fixture and the straight back against the EUROBED ® mechanism plate are wall.
  • Page 7 SECURE RECESS TO WALL - continued Mounting Methods for Wall-Mounting Fixture (see Step 4 of “Secure Recess to Wall,” on page 8) Select the method below which is appropriate to wall structure. Clip Fixture Clip Fixture Clip Fixture Wood Studs Concrete Walls Sheet Metal Studs IMPORTANT: Keep the unit level and...
  • Page 8 1. The recess should already be If using verticals other than those installed, and 1-3/8” holes ® available from SICO , refer to the should be predrilled in each ver- drilling template shipped with each tical for the mechanism plate.
  • Page 9 SECURE BASEPLATE TO FLOOR (if required) 1. The baseplate must be WARNING securely attached to the floor in the following situations: Vertical - When installing the recess Failure to securely against a partition; anchor the system - When installing the recess according to instruc- against a portable wall.
  • Page 10 Baseplate Use six anchors per bed. Use anchors appropriate to the type of ® floor: SICO recommends Red Head NOTICE: SICO does not #HN-1230 1/2 x 3” Expansion 3-1/2” recommend using power- Anchors, or their equivalent. Drill 1/2” dia. Minimum...
  • Page 11 SICO Miscellaneous Floors Customer Service at NOTE: Use anchors appropriate to 1-800-328-6138. the type of floor: SICO recom- Baseplate mends the Star 3/8 x 6” roundhead Thin Concrete toggle bolts or their equivalent. These toggle bolts are not Wood Floor supplied with the bed.
  • Page 12 If you encounter any Joists problem or a unique floor If you encounter a joist at the anchoring Baseplate ® construction, contact SICO location, use the following procedure. Note Thin Concrete Customer Service at that toggles are preferred for anchoring 1-800-328-6138.
  • Page 13 INSTALL BASEPLATE (if not secured to the floor) NOTE: See step 1 on page 9 to determine if the baseplate should be secured to the floor. Vertical 1. Set the baseplate in the recess opening. The side with four holes must be toward the rear wall.
  • Page 14 ATTACH MISCELLANEOUS PARTS TO BED NOTE: For thicker bed faces: the standard Bumper and screw are in the accessory pack marked bed face is 3/8”. For thicker bed faces “107524.” Top of (raised panel, trim, etc.), mount flush with Recess Opening front of recess, add the difference between the actual bed face thickness and 3/8”...
  • Page 15 INSTALL EUROBED IN RECESS ® 1. Back off the mechanism adjuster nuts CAUTION fully. Two people are 2. For the 24/7 EUROBED ® , install toe- required at all times kick with brackets and wood screws at the when placing the bed bottom of the recess opening.
  • Page 16 INSTALL EUROBED ® IN RECESS (continued) 6. Check the alignment of the bed and recess. If the side gaps are not equal (about 1/4” each), insert a large flat- blade screwdriver between the edge of the bed frame and the mechanism plate.
  • Page 17: Parts List

    PARTS LIST DETAIL B Serial Number Label BUMPER DETAIL LEG DETAIL DETAIL B...
  • Page 18 .” Always provide the Serial Number of the bed when ordering parts. SICO Incorporated reserves the right to substitute materials or make changes if materials are not available and such changes improve the product. Visit our website at www.sicoinc.com The Americans Europe SICO America Inc.