Download Print this page

Ripack 2000 User Manual

Hand-held propane-fired heat-appliance intended for plastic film shrinking

Advertisement

- 1 -
USER's GUIDE

Advertisement

loading
Need help?

Need help?

Do you have a question about the 2000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ripack 2000

  • Page 1 - 1 - USER’s GUIDE...
  • Page 2: Table Of Contents

    ROPANE FIRED APPLIANCE INTENDED FOR LASTIC HRINKING USER'S GUIDE GUARANTEE ............... 3 WARNINGS ..............4 START-UP ..............8 EXAMPLES OF USE ..........10 MAINTENANCE ............13 SPARE PARTS ............18 RIPACK 2000 is a product of SEFMAT - F 33185...
  • Page 3: Guarantee

    In the case of dispute, jurisdiction lies solely with the Courts of Bordeaux, France. No other jurisdiction is accepted. The use or the resale of the RIPACK 2000 implies the total acceptance of above conditions. O R A N Y C L A I M U N D E R T H E G U A R A N T E E...
  • Page 4: Warnings

    This appliance is intended exclusively for professional use and for plastic film shrinking. It is essential that users of the RIPACK 2000 heat-gun make themselves familiar with this guide in full and that they be trained in the applications for its use.
  • Page 5 The appliance is also in compliance with the NF-E 65-140 standard covering "portable LPG appliances for the shrinking of heat-shrink films". On the other hand, the RIPACK 2000 cannot carry the CE sign, for the following reasons: 1. "all industrial appliances are excluded from the field of application"...
  • Page 6 - 6 - 2. the RIPACK 2000, like all gas-fired shrink guns, is not considered to be a machine, as: "the mobile part is actuated solely by human force" (directive 98/37/CE on the safety of machines). Consequently, and although the RIPACK 2000 complies with the essential...
  • Page 7 - 7 - PPLIANCE RUNNING ON PROPANE GAS ECHNICAL Operating pressure: (PSI) Consumption (lbs/h) Power (kW) CO Vol % 0.17 0.0075 CO/CO² 0.13 0.037 CO² Vol % 1.80 2.80 Aspirated air (cfm) 8 " Flame stabilization grid Air+Gas mixture Aspirated air chamber Igniter Control tap...
  • Page 8: Start-Up

    Prior to start-up, it is necessary and obligatory to read the preceding warnings and to ensure that the manufacturer of the materials involved has not advised against the use of the appliance. The RIPACK 2000 operates on vaporized propane gas contained in cylinders of varying sizes.
  • Page 9 - 9 - SEALING: ensure there are no leaks on the screwed parts (cylinder, hose and gun connections) with a bubble spray or with soapy water. 5. CAUTION! Ignition of the shrink gun: proceed and in STAGES: SLOWLY 1° Partially push the trigger for 1 second: ...
  • Page 10: Examples Of Use

    - G - under the pallet. Ignite your RIPACK 2000 according to the instructions in the section "Start-Up". ECOMMENDATIONS HRINKING (failing any specific recommendations from the film manufacturer):...
  • Page 11 As the reactions of films differ, observe the reaction of the film and adjust speed and/or distance accordingly. The power of the RIPACK 2000 can also be adjusted by means of its adjustable pressure relief valve according to the different types of film.
  • Page 12 - 12 - Bundling All kinds of items that do not fall within the configuration of a pallet can also be wrapped with a flat film, providing an overlap of at least 1 Ft is left for self-sealing (drawing M). - M - Heat the film in a continuous sweeping movement, pressing down on the overlap with...
  • Page 13: Maintenance

    VERY MONTH connections. Original parts: Each RIPACK 2000 appliance is manufactured with great care from top quality materials. The RIPACK components are stringently checked before the appliance is assembled and tested. For maintenance and replacement of parts, consult a RIPACK products distributor.
  • Page 14 - 14 - To get the best performance from your RIPACK 2000 ROBLEMS AUSES EMEDIES  The burner  Cylinder empty  Check the presence of gas in the cylinder fails to ignite (change the cylinder if or is difficult to required).
  • Page 15  Burner fails to  Trigger stuck  Have the gun checked by  Tap blocked your RIPACK distributor go out Dismantling - Reassembly – Cleaning (drawing Q) ISMANTLING 1. Disconnect the hose from the gun. Open the gun chest and place the appliance on the foam with the ignition wire facing you.
  • Page 16 - 16 - EASSEMBLY 7. Position the ignition-wire 10 in the slot of the front handle block 13 by passing it between the plastic stop B and the body of the gun. Make a loop with the wire inside the lower half of the handle behind the gas tube. 8.
  • Page 17 Check the operation of the gun according to the section "START-UP" and  check with the gun in operation for gas leak at the nut 15 using a bubble spray or soapy water. OR ANY AND ALL SERVICING ON THE GAS SYSTEM PLEASE CONTACT YOUR RIPACK DISTRIBUTOR...
  • Page 18: Spare Parts

    - 18 - SPARE PARTS Pos. Description Code Combustion nozzle 233130 Body 133104 Jet holder 249021 Gas tube 150038 Trigger return spring 148044 Gas tap 248113 Body half-handle right 134050 Body half-handle left 134051 Trigger 137044 9+11 Handle guard support + plate assembly 236060 Ignition wire 236035...
  • Page 19 - 19 -...