Fluidwell F Series Manual page 52

Flow rate indicator / totalizer with analog and pulse outputs
Hide thumbs Also See for F Series:
Table of Contents

Advertisement

Page 52
PDU
REGISTER
ADDRESS
[d] 112
40113
[h] 0x070
[d] 113
40114
[h] 0x071
[d] 116
40117
[h] 0x074
[d] 119
40120
[h] 0x077
[d] 120
40121
[h] 0x078
[d] 122
40123
[h] 0x07A
[d] 127
40128
[h] 0x07F
PDU
REGISTER
ADDRESS
[d] 128
40129
[h] 0x080
[d] 133
40134
[h] 0x085
[d] 130
40131
[h] 0x082
PDU
REGISTER
ADDRESS
[d] 144
40145
[h] 0x090
[d] 145
40146
[h] 0x091
[d] 146
40147
[h] 0x092
[d] 147
40148
[h] 0x093
[d] 150
40151
[h] 0x096
[d] 149
40150
[h] 0x095
[d] 25
40026
[h] 0x019
PDU
REGISTER
ADDRESS
[d] 173
40174
[h] 0x0AD
[d] 160
40161
[h] 0x0A0
[d] 162
40163
[h] 0x0A2
[d] 165
40166
[h] 0x0A5
[d] 168
40169
[h] 0x0A8
[d] 170
40171
[h] 0x0AA
VARIABLE
NO.
ANALOG OUTPUT
REGISTERS
analog output
minimum rate
maximum rate
cut off percentage
tune minimum rate
tune maximum rate
filter
VARIABLE
NO.
PULSE
REGISTERS
pulse width
decimals
amount
VARIABLE
NO.
COMMUNICATION
REGISTERS
speed (Baudrate)
Modbus address
Modbus mode
delay
index
Index use
reboot
VARIABLE
NO.
OTHERS
REGISTERS
model number
model suffix
firmware version
serial no
password
tag-nr
FW_F110-A_M_v2201-02_EN.docx
R/W
TYPE
VALUE / REMARKS
1
R/W
uint16 0=disable
2
R/W
uint32 0...9999999
Representation: unit, time, decimals
depending on variables 48, 49, 50
2
R/W
uint32 0...9999999
Representation: unit, time, decimals
depending on variables 48, 49, 50
1
R/W
uint16 0...99
Representation: 0.0 – 9.9%
1
R/W
uint16 0...9999
1
R/W
uInt16 0...9999
1
R/W
uint16 1...99
R/W
TYPE
VALUE / REMARKS
1
R/W
uint16 0...9999, (0=disabled)
Representation: 0.000 – 9.999 sec
1
R/W
uint16 0...3
2
R/W
uint32 1...9999999
Representation: 0.001 – 9999999
depending on variable 133
R/W
TYPE
VALUE / REMARKS
1
R/W
uint16 0=1200
1
R/W
uint16 1...255
1
R/W
uint16 0: ASCII
1
R/W
uint16 delay between read and write command
0...65355
1
R/W
uint16 used for indexed values
1
R/W
uint16 0=
static
1
R/W
uint16 Returns 0 on read.
Write 0xA50F for unit restart
Write 0x5AF0 for factory settings
R/W
TYPE
VALUE / REMARKS
1
R
uint16 0...9999
1
R
char
Representation: ASCII character
2
R
uint32 0...999999
Representation: nn:nn:nn
2
R
uint32 0...9999999
Representation: nnnnnnn
1
R
uint16 0...9999
2
R/W
uint32 0...9999999
Representation: nnnnnnn
1=enable
1=2400 2=4800
3=9600
1: RTU
2: OFF
1=
2=
increment
decrement