Super SD Manual

Super SD Manual

Mechanical seal pump

Advertisement

Quick Links

Superior Performance
Unbeatable Pricing
Pride in Workmanship
Energy Efficient
Rugged Construction
SD/LD/SL/HD/HL/SE/SG/SN/SAS
Mechanical Seal Pump
Manual

Advertisement

Table of Contents
loading

Summary of Contents for Super SD

  • Page 1 Superior Performance Unbeatable Pricing Pride in Workmanship Energy Efficient Rugged Construction SD/LD/SL/HD/HL/SE/SG/SN/SAS Mechanical Seal Pump Manual...
  • Page 2: Table Of Contents

    INDEX Introduction ............2~10 Model  Feature Application Specification Performance Curve Installation ............11~13 Install Instruction  Examples  Operating ............. 14 Before Operating  Operating Instruction  Maintenance and Repair ........14 Cautions  Maintenance and Repair  Troubleshooting ........... 15 Warning ...............
  • Page 3: Introduction

    4. Corrosion and high temperature resistance. •Application 1. SUPER pumps can be used in a wide variety of industrial applications, such as food, chemical industry, Electro-plating, leather dyeing, waste and pollution control. 2. Wide material selection ensures high performance of corrosion resistance.
  • Page 4 75x75 43 / 56 / 84 SD / SL 75072H 75x75 26.5 52 / 56 / 120 SL 75102H 75x75 1000 •SD / LD / SL Performance Curves LD SD SL Series 600 700 900 1000 600 700 900 1000...
  • Page 5 H - Hastelloy - C S - SUS316 •Model HD - 40 L - SSH - 6 (9) (10) (1) TYPE -HD (5) Elastomer (8) Seal Combination (2) In-Outlet V - VITON CCH, SCH,SSH 40-1.5", 50-2",65-2.5" N - NBR (9) Frequency 75-3"...
  • Page 6 •Model SE - SK - 1/2 (9) (10) (1) TYPE -SE (8) Fixed-seal (5) Frequency (2) In-Outlet C - Ceramic 5-50HZ, 6-60HZ 25-1" 40-1.5" S - SSIC (6) Elastomer (3) Specific Gravity (9) Rotational-seal V - VITON SK - 1.1 C - Carbon N - NBR (4) Power (HP)
  • Page 7 •MODEL AND STYLE - 40 02 - H - C (5) (6) (7) (8) (9) (10) (11) TYPE 2-2P Pole (8) Rotational-seal SG-FRPP SGK-PVDF C- Carbon Elastomer S- SSIC SGK-PVDF (9) Bellows Spring In-Outlet H-Hastelloy-C S-SUS316 125-5" (10) Frequency Power (HP)
  • Page 8: Specification

    HL - 2 - V H - SSH (9) (10) (1) TYPE -HD (5) Elastomer (8) Seal Combination (2) In-Outlet V - VITON CCH, SCH,SSH 40-1.5", 50-2",65-2.5" N - NBR (9) Frequency 75-3" E - EPDM 5-50HZ, 6-60HZ (3) Power (HP) (6) B-No Check Lid (10) N-Normal 3-3HP, 5-5HP...
  • Page 9 SN - 2 - N H - C H - 5 (5) (6) (7) (8) (9) (10) (11) TYPE 2:2P Pole SN - FRPP Elastomer SNK - PVDF N - NBR In-Outlet E - EPDM 40-1.5", 50-2", 75-3" V - VITON 100-4", 125-5"...
  • Page 10 SAS - 40 N - 5 (3) (4) (1) TYPE -SAS (4) H-High head (7) Elastomer (2) In-Outlet N - NBR (5) Seal 25-1", 40-1.5", 50-2" E - EPDM T-Teflon Bellows Ssic 65-2.5", 75-3" V - VITON C-Ceramin+Carbon (3) Power (HP) T-Teflon (6) Material 1/2-1/2HP, 1-1HP, 2-2HP...
  • Page 11 SAS - 40 N - 5 (3) (4) (1) TYPE -SAS (4) L-Low head (7) Elastomer (2) In-Outlet (5) Seal N - NBR 25-1", 40-1.5", 50-2" E - EPDM T-Teflon Bellows Ssic 65-2.5", 75-3" V - VITON C-Ceramin+Carbon (3) Power (HP) T-Teflon (6) Material 1/2-1/2HP, 1-1HP, 2-2HP...
  • Page 12: Installation

    2. Installation 1. Place the machine in a horizontal position and on a sturdy-resting place. Keep the pump level and install valves on the inlet and outlet of the pump for easy maintenance. 2. If the pump must be installed outdoors, it is essential to provide adequate covering, especially if the pump is equipped with an electrical switch.
  • Page 13 •Examples • When applied to heat-exchange, install a pressure gauge at the outlet to ensure no blockage in the pipeline. • A strainer should be installed at the inlet to revent solids from being sucked in. • Install valves at the inlet and the outlet for easy maintenance.
  • Page 14 • When applied to tank, • Monitoring the level in the tank to prevent from dry running. • For SD pump, check valve(part no.14) without check lid is recommended. • Install Check valve if the discharge pipeline is over 8M high.
  • Page 15: Examples 3. Operating

    3. Operation •Before Operating 1. Please note the following operating factors before using the pump: fluid series, concentration, temperature, specific gravity, solid particles and/or deposits, capacity, head, voltage, and cycle. 2. Check the electrical connections and make sure that the motor rotates in the direction shown on the fan cover of the motor.
  • Page 16: Troubleshooting

    5. Trouble shooting Trouble Possible Cause Remedy Motor doesn’t No Motor burnout. Recoil the motor power. Check the No power. Check the power supply. Electromagnetic switch turns off the Checking whether motor is overloaded; power supply. pump. If the switch is not working correctly, work.
  • Page 17: Warning

    6. Warning 1. Different chemical solutions mixed together will cause reaction and even heat to damage the pump. Don’t pump different chemical solutions with the same pump. 2. Chemicals may cause serious injury. Keep away from dangerous area. 3. Before operating, please check the discharge and suction line and valves first.
  • Page 18: Appendix

    7. Appemdix...
  • Page 19 ¡¡ ¡¡ 1/2~5HP 0.75~2.2.5kW ¡¡ ¡¡ 12-1 10-1 16-1 15-1 10-2 ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ 16-1 16-1 For Filter ¡¡ ¡¡ ¡¡...
  • Page 20 1/2~2HP 0.4kW~1.5kW 1~15HP 0.75~11kW 10-1 10-2 12-1...
  • Page 21 3~10HP 2.2~7.5kW 1~10HP 0.75~7.5kW...
  • Page 22 11-4 11-3 11-1 11-2 10-1 10-2...
  • Page 23 • SD / LD / SL / HD / HL / SN Parts list LD 型一體成型 後蓋 O 環 馬達 腳座軸承 軸承防塵蓋 軸承防水套 後封蓋 腳座 Motor Frame Bearing Bearing Bearing Rear cover Rear Cover 後封蓋 Frame Dust Shield Liquid Shield...
  • Page 24 Self-Priming Self-Priming O 環 Self-Priming Base for SL Coupling Coupling Coupling 腳架 Cover Cover Screw Cover Screw Cover Packing Base Elastomer Shield O-ring for SD/SL NBR / EPT NBR / EPT PVDF FRPP FRPP / PVDF / VITON / VITON...
  • Page 25: Data Card

    8. Data Card Date: Company Name Address Unit / Dept. TEL: Name Request a Catalog ( Staff to Negotiate ( Field Trials ( Other ( Industry Category Metal Products Factory Aluminum Anodizing Plant Dyed plant Metal Processing Plating Electronic PC Board Manufacturer 12. Pharmaceutical Factory OEM Chemical Plating Plant Semiconductor Manufacturing...
  • Page 26: Quality Quarantee

    3. The consumable parts and accessories are not covered in the guarantee. 4. guarantee period: 1 year after delivery Should you have any question, please contact our dealer or Super Giant Enterprise directly. Address: No.7 Lane 404 Chung Cheng South Road, Yen Hang, Yung Kang, Tainan, Taiwan, R.O.C.
  • Page 27 Please kindly provide us the following information. 1. Chemical: Name/Concentration/Temperature/   Specific Gravity/Viscosity 2. Capacity needed:__________L/min 3. Head needed:__________M 4. Power: Voltage/Frequency SUPER GIANT ENTERPRISE CO., LTD. No.7, Lane 404, Chung Cheng South Road, Yen Hang, Yung Kang, Tainan, Taiwan, Tel:886-6-2534546, 2541601 Fax:886-6-2534226, 2420509 E-mail:super@superpump.tw Website:http://superpump.tw...

Table of Contents