Page 1
Superior Performance Unbeatable Pricing Pride in Workmanship Energy Efficient Rugged Construction SD/LD/SL/HD/HL/SE/SG/SN/SAS Mechanical Seal Pump Manual...
4. Corrosion and high temperature resistance. •Application 1. SUPER pumps can be used in a wide variety of industrial applications, such as food, chemical industry, Electro-plating, leather dyeing, waste and pollution control. 2. Wide material selection ensures high performance of corrosion resistance.
Page 5
H - Hastelloy - C S - SUS316 •Model HD - 40 L - SSH - 6 (9) (10) (1) TYPE -HD (5) Elastomer (8) Seal Combination (2) In-Outlet V - VITON CCH, SCH,SSH 40-1.5", 50-2",65-2.5" N - NBR (9) Frequency 75-3"...
Page 6
•Model SE - SK - 1/2 (9) (10) (1) TYPE -SE (8) Fixed-seal (5) Frequency (2) In-Outlet C - Ceramic 5-50HZ, 6-60HZ 25-1" 40-1.5" S - SSIC (6) Elastomer (3) Specific Gravity (9) Rotational-seal V - VITON SK - 1.1 C - Carbon N - NBR (4) Power (HP)
Page 7
•MODEL AND STYLE - 40 02 - H - C (5) (6) (7) (8) (9) (10) (11) TYPE 2-2P Pole (8) Rotational-seal SG-FRPP SGK-PVDF C- Carbon Elastomer S- SSIC SGK-PVDF (9) Bellows Spring In-Outlet H-Hastelloy-C S-SUS316 125-5" (10) Frequency Power (HP)
HL - 2 - V H - SSH (9) (10) (1) TYPE -HD (5) Elastomer (8) Seal Combination (2) In-Outlet V - VITON CCH, SCH,SSH 40-1.5", 50-2",65-2.5" N - NBR (9) Frequency 75-3" E - EPDM 5-50HZ, 6-60HZ (3) Power (HP) (6) B-No Check Lid (10) N-Normal 3-3HP, 5-5HP...
Page 9
SN - 2 - N H - C H - 5 (5) (6) (7) (8) (9) (10) (11) TYPE 2:2P Pole SN - FRPP Elastomer SNK - PVDF N - NBR In-Outlet E - EPDM 40-1.5", 50-2", 75-3" V - VITON 100-4", 125-5"...
Page 10
SAS - 40 N - 5 (3) (4) (1) TYPE -SAS (4) H-High head (7) Elastomer (2) In-Outlet N - NBR (5) Seal 25-1", 40-1.5", 50-2" E - EPDM T-Teflon Bellows Ssic 65-2.5", 75-3" V - VITON C-Ceramin+Carbon (3) Power (HP) T-Teflon (6) Material 1/2-1/2HP, 1-1HP, 2-2HP...
Page 11
SAS - 40 N - 5 (3) (4) (1) TYPE -SAS (4) L-Low head (7) Elastomer (2) In-Outlet (5) Seal N - NBR 25-1", 40-1.5", 50-2" E - EPDM T-Teflon Bellows Ssic 65-2.5", 75-3" V - VITON C-Ceramin+Carbon (3) Power (HP) T-Teflon (6) Material 1/2-1/2HP, 1-1HP, 2-2HP...
2. Installation 1. Place the machine in a horizontal position and on a sturdy-resting place. Keep the pump level and install valves on the inlet and outlet of the pump for easy maintenance. 2. If the pump must be installed outdoors, it is essential to provide adequate covering, especially if the pump is equipped with an electrical switch.
Page 13
•Examples • When applied to heat-exchange, install a pressure gauge at the outlet to ensure no blockage in the pipeline. • A strainer should be installed at the inlet to revent solids from being sucked in. • Install valves at the inlet and the outlet for easy maintenance.
Page 14
• When applied to tank, • Monitoring the level in the tank to prevent from dry running. • For SD pump, check valve(part no.14) without check lid is recommended. • Install Check valve if the discharge pipeline is over 8M high.
3. Operation •Before Operating 1. Please note the following operating factors before using the pump: fluid series, concentration, temperature, specific gravity, solid particles and/or deposits, capacity, head, voltage, and cycle. 2. Check the electrical connections and make sure that the motor rotates in the direction shown on the fan cover of the motor.
5. Trouble shooting Trouble Possible Cause Remedy Motor doesn’t No Motor burnout. Recoil the motor power. Check the No power. Check the power supply. Electromagnetic switch turns off the Checking whether motor is overloaded; power supply. pump. If the switch is not working correctly, work.
6. Warning 1. Different chemical solutions mixed together will cause reaction and even heat to damage the pump. Don’t pump different chemical solutions with the same pump. 2. Chemicals may cause serious injury. Keep away from dangerous area. 3. Before operating, please check the discharge and suction line and valves first.
8. Data Card Date: Company Name Address Unit / Dept. TEL: Name Request a Catalog ( Staff to Negotiate ( Field Trials ( Other ( Industry Category Metal Products Factory Aluminum Anodizing Plant Dyed plant Metal Processing Plating Electronic PC Board Manufacturer 12. Pharmaceutical Factory OEM Chemical Plating Plant Semiconductor Manufacturing...
3. The consumable parts and accessories are not covered in the guarantee. 4. guarantee period: 1 year after delivery Should you have any question, please contact our dealer or Super Giant Enterprise directly. Address: No.7 Lane 404 Chung Cheng South Road, Yen Hang, Yung Kang, Tainan, Taiwan, R.O.C.
Page 27
Please kindly provide us the following information. 1. Chemical: Name/Concentration/Temperature/ Specific Gravity/Viscosity 2. Capacity needed:__________L/min 3. Head needed:__________M 4. Power: Voltage/Frequency SUPER GIANT ENTERPRISE CO., LTD. No.7, Lane 404, Chung Cheng South Road, Yen Hang, Yung Kang, Tainan, Taiwan, Tel:886-6-2534546, 2541601 Fax:886-6-2534226, 2420509 E-mail:super@superpump.tw Website:http://superpump.tw...