WARNING: This Frost Resistant Package must be installed on an interior heated wall. The front of the box must have unobstructed air flow. Failure to maintain the interior wall temperature and the inside of the Frost Resistant Package at an above freezing temperature can and will cause damage to the Frost Resistant Package.
Page 2
ALTERNATE IN-WALL INSTALLATION 1, 14 SUPPLY LINE INSULATE WALL CAVITY Supply line must slope. Supply water must drain to prevent line freeze up. The frost resistant package may be surface mounted or recessed on an interior wall in a heated area. If recessed, the surface of the cover (Item.
Page 4
Actuation of Quick Connect Water Fittings: Frost resistant box is provided with lead-free connectors which utilize an o-ring water seal. To remove tubing from the fittings, relieve water pressure, push in on gray collar while pulling on the tubing (See Fig. 4). To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4”.