In Case of Indoor Unit Connect With 1:1 Outdoor Unit
The power supply can be selected to connect to indoor unit or outdoor unit. Choose proper way and connect the power supply and connecting
cable by follow the instruction as following.
Power supply cable
Power supply cable
connect to
Connecting cable
Connecting cable
connect to
Connecting cable
Connecting cable
connect to
Power Supply Input at Indoor Unit Terminal Block (Recommend)
Indoor Unit
Terminal block (L N 1 2 3)
Earth line
Power supply
cable
Terminal block (L N 1 2 3)
Earth line
Earth line
Power supply
Connecting
cable
cable
Power Supply Input at Outdoor Unit Terminal Block (Optional)
Indoor Unit
Terminal block (L N 1 2 3)
Earth line
Connecting cable
Stripping length of the power
supply cable
Earth line
50 mm
10 mm
N
L
10 mm
70 mm
Stripping length of the
connecting cable
Earth line
50 mm
10 mm
3
10 mm
70 mm
Stripping length of the
connecting cable
Earth line
50 mm
10 mm
3
2
1
10 mm
70 mm
16
Outdoor Unit
1 2 3
1 2 3
Earth line
Connecting cable
Outdoor Unit
Earth line
Earth line
Connecting cable
Power cord