Clamping Smart Modules Spvxxx-R60Lwmg And Spvxxx- R60Lbmg - SolarEdge SPV-60MMJ Series Installation Manual

Smart modules
Hide thumbs Also See for SPV-60MMJ Series:
Table of Contents

Advertisement

Clamping smart modules SPVxxx-R60LWMG and SPVxxx- R60LBMG

Modules may be placed with their long side perpendicular to the frame or parallel with the frame, as
shown below.
Slide M8 bolts through the rail grooves at the four clamp locations.
Attach each aluminum mounting clamp with an M8 (5/16") bolt and an M8 (5/16") nut. Tighten the
nuts to a torque of between 17N·m to 23N·m (12.5lbf·ft to 17.0lbf·ft) for coarse thread bolts. Secure
each clamp with a plain washer, spring washer, and nut, in that order.
The clamps must overlap the module frame by at least 5mm (0.2in). Ensure that the clamps' length is
at least 40mm (1.57in). The clamp's thickness must at least 3mm (0.12in).
NOTE
For configurations where the long side of the module runs parallel to the frame, take
precautions to ensure that the bottom flange of the module frame overlaps the rail by at
least 15mm (0.59in).
Smart Modules Installation Guide MAN-01-00520-2.7
Specific clamping details
16