10-5-6, Emphasis Y Level Adjustment (Va-68 Board); Pb Ccd Input Level Adjustment (Va-68 Board); Pb Y Level Adjustment (Va-68 Board) - Sony Video8 CCD-F501 Service Manual

Table of Contents

Advertisement

10-5-6.
Emphasis Y Level Adjustment
(VA-68 Board)
Mode
Recording
Signal
Color bar
Measurement Point
Pin © of IC201
Measuring Instrument | Oscilloscope
Adjusting Element
RV202
Specified Value
0.50 = 0.025 Vp-p
Adjusting method:
1) Adjust RV202 for 0.50 + 0.025 Vp-p.
je White (100%)
0.50 + 0.025 Vp-p
pH
Fig. 10-14.
10-5-7.
PB CCD input Level Adjustment
(VA-68 Board)
Mode
Playback
Alignment tape:
Signal
For operation checking (WRS5-SNSP)
color bar section
Measurement Point
Pin @ of IC201
Measuring Instrument | Oscilloscope:
Adjusting Element
RV210
Specified Value
0.50 + 0.025 Vp-p
Adjusting method:
1) Adjust RV210 for 0.50 + 0.025 Vp-p.
2) Be sure to perform "PB Y level adjustment" after this
adjustment.
White (100%)
0.50 + 0.025 Vp-p
Fig. 10-15,
10-5-8.
PB Y Level Adjustment (VA-68 Board)
Mode
Playback
Alignment tape:
Signal
For operation checking (WR5-SNSP)
Color bar section
VIDEO IN/OUT terminal (3201)
Measurement Point
Measuring Instrument | Oscilloscope
Adjusting Element
| RV203.
Specified Value
1.00 + 0.05 Vp-p
Note: 1) Terminate VIDEO IN/OUT terminal (J201) at 75Q .
2) Make sure that "PB CCD Input Level Adjustment" has
been completed.
Adjusting method:
1) Adjust RV203 for 1.00 + 0.05 Vp-p.
ge
White (100%)
1.00 + 0.05 Vp-p
Fig. 10-16
299 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

Video8 ccd-f555

Table of Contents