Download Print this page

Whirlpool AKT 6400 NB Instructions page 4

Advertisement

PRATICAL ADVICE FOR USING THE BURNERS
This hob has burners of different diameters. For better burner performance,
please stick to the following rules:
-
Use pots and pans with bottoms the same width as that of the burners or
slightly larger (see table on the right).
-
Only use flat-bottomed pots and pans.
-
Use the correct amount of water for cooking foods and keep the pot covered.
-
Make sure pots on the grates do not protrude beyond the edge of the hob
-
In the case of pans with convex bottoms (WOK), use the support grille
provided, which should be positioned only on the 4 ring burner.
IMPORTANT: improper use of the grids can result in damage to the hob: do
not position the grids upside down or slide them across the hob.
Do not use:
-
Cast iron griddles, ollar stones, terracotta pots and pans.
-
Heat diffusers such as metal mesh, or any other types.
-
Two burners simultaneously for one receptacle (e.g. fish kettle).
Liquids spilled on hot hob area can cause glass damage.
HOW TO USE THE HOB
Do not let the burner flame extend beyond the edge of the pan.
WARNING
IMPORTANT: WHEN THE HOB IS IN USE, THE ENTIRE HOB AREA MAY BECOME HOT.
To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting.
Press the knob against the control panel to ignite the burner.
After the burner has ignited, keep the knob pressed for about 5-10 seconds to allow proper device operation.
This burner safety device shuts off the gas supply to the burner if the flame goes out accidentally (because of sudden
draught, an interruption in the gas delivery, boiling over of liquids, etc.).
The knob must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not remain lit,
wait at least one minute before trying to light it again.
NOTE: should particular local conditions of the delivered gas make the ignition of burner difficult, it is advisable to repeat
the operation with the knob turned to small flame setting.
The burner might go out when the knob is released. This means that the safety device has not warmed up enough. In this
case, repeat the operations described above.
DIMENSIONS AND DISTANCES TO BE MANTAINED (mm)
NOTE: if the distance "A" between the wall cabinets is
between 600 mm and 730 mm, the height "B" must be a
minimum of 530 mm.
If the distance "A" between the wall cabinets is greater
than the width of the cooktop, the height "B" must be a
minimum of 400 mm.
In case of installation of a hood above the cooktop, please
refer to the hood instructions for the correct distance
Burner
Rapid
Semi-rapid
Auxiliary
max.R 6,5
max.R 8
INJECTORS TABLE
Pot Ø
Type of gas
Type of burner
From 24 to 26 cm
used
From 16 to 22 cm
From 8 to 14 cm
Rapid
NATURAL GAS
Semi-rapid
(Methane) G20
Auxiliary
Rapid
NATURAL GAS
Semi-rapid
G2.350
Auxiliary
Rapid
NATURAL GAS
Semi-rapid
G27
Auxiliary
Rapid
LIQUEFIED
PETROLEUM GAS
Semi-rapid
(Propane) G31
Auxiliary
Type of gas used
configuration
G20 20 mbar
1 R - 2 SR - 1 AUX
G2.350 13 mbar
1 R - 2 SR - 1 AUX
G27 20 mbar
1 R - 2 SR - 1 AUX
G30/G31 37 mbar
1 R - 2 SR - 1 AUX
ELECTRIC SUPPLY: 220-240 V ~ 50/60 Hz
WOK ADAPTER
(not included,this accessory can be purchased separately from the After-sales Service)
Injector
Rated thermal
Rated
marking
flow rate
consumption
kW
128B
3.00
286 l/h
95
1.65
157 l/h
78A
1.00
95 l/h
179A
3.00
397 l/h
129A
1.65
218 l/h
104
1.00
132 l/h
143
3.00
348 l/h
106A
1.65
192 l/h
85
1.00
116 l/h
88
3.00
218 g/h
62
1.65
120 g/h
47
1.00
73 g/h
Model
Rated thermal
Total rated
flow rate (kW)
consumption
7.30
695 l/h
7.30
965 l/h
7.30
848 l/h
7.30
531 l/h
CATEGORY II2ELwLs3B/P
Reduced heat
Gas pressure
capacity kW
mbar
min.
rat.
max.
0.60
0.35
16
20
25
0.30
0.60
0.35
10
13
16
0.30
0.60
0.35
16
20
23
0.30
0.70
0.45
25
37
45
0.35
3
Air required (m
) for
3
burning 1 m
of gas
9.52
6.85
7.90
30.94

Advertisement

loading