Maintenance (only for approved specialists)
8.5

Safety thermostat

The appliance is equipped with automatic safety equipment. If
for any reason the temperature of the water in the appliance
rises above the safety limit, this device cuts the power to the
appliance, preventing any potential accident.
DANGER
Risk of electric shock!
The thermostat must be reset by an authorised person only!
This device must be reset manually and only after having
eliminated the issue which caused it to be activated.
To reset the device:
▶ Disconnect the appliance from the electricity.
▶ Loosen the screws on the appliance cover and remove it.
▶ Check the electrical connections.
▶ Press the button on the safety equipment.
If the safety thermostat is activated on a frequent basis:
▶ ensure more regular cleaning of the electric heater.
Fig. 15
Safety thermostat (Tronic 1000T)
170
Fig. 16
Safety thermostat (Tronic 2000T)
8.6

Inside of the tank

The storage of water at high temperatures and the
characteristics of the water itself can cause a layer of scale to
build up on the surface of the electric heater and/or the
accumulation of detritus in the interior of the tank, affecting
mainly:
water quality
power consumption
appliance functionality
appliance service life
Amongst other things, the abovementioned consequences lead
to a lower thermal transfer between the heater and the water,
causing the thermostat to start/stop more frequently, higher
power consumption and potential safety activation if
temperature limits are breached (manual resetting of
thermostat necessary).
For optimal functioning, the following recommendations are
made:
▶ Clean the interior of the tank.
▶ Clean the electric heater (descale or replace).
▶ Inspect the magnesium anode.
▶ Replace the sealing collar of the flange.
The abovementioned interventions are not covered by the
appliance warranty.
8.7

Restarting after maintenance work

▶ Tighten all water connections and check them for tightness.
▶ Switch on the appliance.