Yamaha SW1000XG Data List page 72

Pci audio midi card
Hide thumbs Also See for SW1000XG:
Table of Contents

Advertisement

1.5 Pitch bend
This message conveys movements of the pitch bender.
This message is generally used to modify the pitch of a part, but the depth
of the following seven effects can be controlled.
The effect of this message can be modified by the following parameters.
• Multi Part Parameter
1. BEND PITCH CONTROL
2. BEND FILTER CONTROL
3. BEND AMPLITUDE CONTROL
4. BEND LFO PMOD DEPTH
5. BEND LFO FMOD DEPTH
6. BEND LFO AMOD DEPTH
• Effect1 Parameter
7. BEND VARIATION CONTROL DEPTH
(Valid when Variation Effect is assigned to a part as Insertion)
By default, the Pitch Control effect is applied.
If the receive channel is a drum part, effects 5 and 6 will not apply.
If the Multi Part parameter Rcv PITCH BEND CHANGE = OFF, that part will
not receive pitch bend messages.
1.6 Channel aftertouch
This message conveys the pressure which is applied to the keyboard after
playing a note in order to create tonal changes (for an entire MIDI channel).
The pressure can be controlled for each part. This message will affect the
currently-sounding notes.
The effect of this message will be determined by the settings of the following
parameters.
• Multi Part Parameter
1. CAT PITCH CONTROL
2. CAT FILTER CONTROL
3. CAT AMPLITUDE CONTROL
4. CAT LFO PMOD DEPTH
5. CAT LFO FMOD DEPTH
6. CAT LFO AMOD DEPTH
• Effect1 Parameter
7. CAT VARIATION CONTROL DEPTH
(Valid when the Variation Effect is assigned to a part as Insertion)
By default, there will be no effect.
If the receive channel is a drum part, effects 5 and 6 will not apply.
If the Multi Part parameter Rcv CHANNEL AFTER TOUCH = OFF, that part
will not receive Channel Aftertouch.
1.7 Polyphonic aftertouch
This message conveys the pressure that is applied to the keyboard after
playing a note (for individual note numbers).
The pressure can be controlled independently for each note. This message
will affect currently-sounding notes.
The effect of this message is determined by the following Multi Part parame-
ters.
1. PAT PITCH CONTROL
2. PAT FILTER CONTROL
3. PAT AMPLITUDE CONTROL
4. PAT LFO PMOD DEPTH
5. PAT LFO FMOD DEPTH
6. PAT LFO AMOD DEPTH
By default, there will be no effect.
The effect will apply to note numbers 36...97.
In the case of either of the following Multi Part parameter settings, that part
will not receive Polyphonic Aftertouch.
Rcv CHANNEL AFTER TOUCH = OFF
PART MODE = DRUM, DRUMS1...4
2. System exclusive messages
2.1 Parameter changes
This device uses the following parameter changes.
[UNIVERSAL REALTIME MESSAGE]
1)
Master Volume
[UNIVERSAL NON REALTIME MESSAGE]
1)
General MIDI System On
[XG PARAMETER CHANGE]
1)
XG System on
2)
XG System parameter change
3)
Multi Effect1 parameter change
4)
Multi EQ parameter change
5)
Multi Effect2 parameter change
6)
Multi Part parameter change
7)
Audio Part parameter change
8)
Audio Part Configuration parameter change
9)
Drums Setup parameter change
[SW1000XG NATIVE PARAMETER CHANGE]
1)
System parameter change
[Others]
1)
Master tuning
2)
TG300 System parameter change
3)
TG300 Multi Effect parameter change
4)
TG300 Multi Part parameter change
2.1.1 Universal realtime messages
2.1.1.1 Master Volume
11110000
F0H
Exclusive status
01111111
7FH
Universal Real Time
01111111
7FH
ID of target device
00000100
04H
Sub-ID #1 = Device Control Message
00000001
01H
Sub-ID #2 = Master Volume
* 0sssssss
SSH
Volume LSB
0ttttttt
TTH
Volume MSB
11110111
F7H
End of Exclusive
or,
11110000
F0H
Exclusive status
01111111
7FH
Universal Real Time
0xxxnnnn
XNH
Device Number,
00000100
04H
Sub-ID #1 = Device Control Message
00000001
01H
Sub-ID #2 = Master Volume
0sssssss
SSH
Volume LSB
0ttttttt
TTH
Volume MSB
11110111
F7H
End of Exclusive
When this is received, the Volume MSB will be reflected by the System
parameter MASTER VOLUME.
* The binary expression 0sssssss is expressed in hexadecimal as SSH.
The same applies elsewhere.
2.1.2 Universal non-realtime messages
2.1.2.1 General MIDI System On
11110000
F0H
Exclusive status
01111110
7EH
Universal Non-Real Time
01111111
7FH
ID of target device
00001001
09H
Sub-ID #1 = General MIDI Message
00000001
01H
Sub-ID #2 = General MIDI On
11110111
F7H
End of Exclusive
or,
11110000
F0H
Exclusive status
01111110
7EH
Universal Non-Real Time
0xxxnnnn
XNH
N:Device Number, X:don't care
00001001
09H
Sub-ID #1 = General MIDI Message
00000001
01H
Sub-ID #2 = General MIDI On
11110111
F7H
End of Exclusive
When this message is received, the SOUND MODULE MODE is set to XG,
and all MIDI messages defined by GM will be received.
All data except for MIDI Master Tuning will be restored to the default value.
However this message will not be received in any of the following cases.
• XG Model System Parameter (see table 2-2) Rcv SYSTEM ON MES-
SAGE= OFF
Since approximately 50[ms] is required in order to process this message, be
sure to allow an appropriate interval before sending the next message.
72
xxx = don't care

Advertisement

Table of Contents
loading

Table of Contents