4.2

IP address assignment

An IP address must be assigned to the device to access the command line and Web
interfaces. The device is not assigned an IP address by default.
During initial commissioning, use one of the following methods to assign an IP
address to the device:
4.3

Configuring the device

Once the device is installed and connected to the network, it must be configured. All
configuration management is done via RUGGEDCOM ROS.
For more information, refer to the
support.industry.siemens.com/cs/ww/en/ps/24744/man]
software release.
4.4

Inserting/removing the CLP

The device accepts a CLP for storing configuration files and/or software updates. A
protective cover is provided to prevent the ingress of dust and dirt when the CLP is
not in use.
RUGGEDCOM RST2228P
Equipment Manual, 10/2023, C79000-G8976-1403-17
Connect the device to a DHCP server
The device is configured by default to connect with a DHCP server. Once
connected, an IP address is assigned automatically.
For more information, refer to the
support.industry.siemens.com/cs/ww/en/ps/24744/man]
installed software release.
Set an IP address with SINEC PNI
Use the SINEC PNI (Primary Network Initialization) tool to manually assign a static
IP address to the device. Requires a Windows PC and Ethernet connection.
For more information, refer to
ps/26672.
Set a static IP address through a serial connection
1.
Connect a PC to the USB serial console port and establish a serial connection
with a terminal emulator, such as PuTTy or Tera Term.
For more information, refer to "Connecting to the device" (Page 47).
2.
Through the ROS console or Web interface, add or modify the Switch IP
interface for VLAN1.
For more information, refer to
support.industry.siemens.com/cs/ww/en/ps/24744/man]
installed software release.
"ROS Configuration Manuals" [https://
https://support.industry.siemens.com/cs/ww/en/
"ROS Configuration Manuals" [https://
"RUGGEDCOM ROS Configuration Manual" [https://
Device management
4.2 IP address assignment
associated with the
associated with the
associated with the installed
49