● Starting Self-Diagnostic Function
1. Turn the BASS, TREBLE and BALANCE knobs fully
clockwise.
2. Press the " " (Power) key to turn on the power.
Then the " " (Power) indictor will turn on.
3. While pressing the " " (Power) key, turn the BASS,
TREBLE and BALANCE knobs fully counterclockwise.
4. Release the " " (Power) key.
Then the " " (Power) indicator will flash and the self-
diagnostic function will be activated.
Front view
"
" (Power) indicator
    (電源) インジケーター
"
" (Power) key
    (電源) キー
Lighting
点灯
2.
Press
押す
Flashing
点滅
4.
Release
離す
● Canceling Self-Diagnostic Function
Before canceling self-diagnostic function, execute setting
for "7. SET TO FACTORY DEFAULT CONDITION" menu
(Back-up data initialized).
*
To Keep the user memory, do not make setting.
Press the power key for 2 seconds or longer, and the " "
(Power) indictor will turn off and the power will be shut off.
TREBLE knob
TREBLE ツマミ
BASS knob
BASS ツマミ
1.
3.
Counterclockwise
反時計回り
Press and hold
押したまま
CD-NT670/CD-NT670D display
P R T   E n b
U 6 7 0   D i a g   M o d e
A-U670/A-670/A-U671/NS-BP401/NS-BP301
●  ダイアグの起動
1.  BASS ツマミ、TREBLE ツマミ、および BALANCE ツマ
ミを右いっぱいに回します。
2.  " "(電源)キーを押して電源を入れます。
" "(電源)インジケーターが点灯します。
3.  次に " "(電源)キーを押しながら、BASS ツマミ、
TREBLE ツマミ、および BALANCE ツマミを左いっぱい
に回します。
4.  " "(電源)キーを放します。
" "(電源)インジケーターが点滅し、ダイアグが起
動します。
BALANCE knob
BALANCE ツマミ
Startup mode
Protection Enable: Protection mode
Model name
U670: A-U670
A670: A-670
●  ダイアグの解除
ダイアグを解除する前に、"7.  SET  TO  FACTORY  DEFAULT 
CONDITION" メニュー(バックアップデータの初期化)
の設定をします。
※  ユーザーメモリーを保持したい場合は、設定をしない
でください。
電源キーを 2 秒以上押すと、" "(電源)インジケーター
が消灯して電源が切れます。
Clockwise
時計回り