ESTA Apparatebau GmbH & Co. KG
Removal
675160-52-00_FILTOWER L-160 4.0
8.8 Changing the filter cartridge
CAUTION
Harmful separated substances
Effects on respiration, organs, skin and eyes
4
Maintenance, cleaning, repair, and emptying work may only be com-
pleted by expert personnel.
4
Wear personal protective equipment.
4
Personal protective equipment must be impermeable and resistant to
harmful substances.
4
Ensure that the ball valve of the collection tank is closed.
4
Ensure that the collection container is attached to the discharge
opening.
4
Ensure that inspection doors are firmly closed.
4
Stop leaks with binding agents and dispose of them according to local
regulations.
4
When handling separated harmful substances, observe the manufac-
turer's safety data sheets with regard to components and effects.
After an extended period of operation, the filter elements clog up slowly
due to the ingress of extremely fine dust (wear debris), dust deposits,
resinous oil, and fatty residues in the pores. Filters must be replaced
with new ones.
1. Switch off extraction on the control panel, refer to the chapter Oper-
ating the product [} 27].
2. Switch off the product at the main switch and secure it from re-oper-
ation (e.g. with a padlock).
1. Unlock and open the inspection door.
2. If the anti-static version of filter cartridge is used, disconnect the
earthing cable from the earthing screw on the filter cartridge (op-
tional).
3. Unfasten retaining screws slightly and tilt the holder downwards.
4. Wrap a disposal bag around the front filter cartridge and secure it
with cable ties.
5. Loosen the front and middle screws on both the left and right of the
guide rail.
ð The guide rail will drop to the end stop.
6. Remove the packaged filter cartridge from the guide rail.
Servicing and maintenance 8