GCL RY-12K-AUP3 User Manual page 38

Table of Contents

Advertisement

Grid Setting/V(W) V(Q)
V(W)
P1
V1
V1
P2
V2
V2
P3
V3
V3
P4
V4
V4
For example: V2=110%, P2=80%. When the grid voltage reaches the 110% �mes of rated grid voltage,
inverter output power will reduce its ac�ve output power to 80% rated power.
For example: V1=94%, Q1=44%. When the grid voltage reaches the 94% �mes of rated grid voltage,
inverter output power will output 44% reac�ve output power.
For the detailed setup values, please follow the local grid code.
Grid Setting/P(Q) P(F)
P(Q)
Q1
P1
P1
Q2
P2
P2
Q3
P3
P3
Q4
P4
P4
Grid Setting/LVRT
L/HVRT
HV3
HV3_T
0%
0.00s
HV2
HV2_T
0%
0.00s
HV1
HV1_T
0%
0.00s
LV1
LV1_T
0%
0.00s
LV2
LV2_T
0%
0.00s
Basic Setting
Time Syncs
Beep
Year
Month
2019
03
Hour
24-Hour
09
Factory Reset
5.8.3 Grid Parameter Check
A�er steps above, customers can see firmware version on main page grid parameters in grid
se�ngs on LCD.
V(Q)
Lock-in/Pn
Lock-out/Pn
Grid
Set5
Q1
Q2
Q3
Q4
P(PF)
Lock-in/Pn
Lock-out/Pn
Grid
Set6
PF1
PF2
PF3
PF4
Grid
Set7
Auto Dim
Day
Basic
Set
17
Minute
15
Lock out all changes
V(W): It is used to adjust the inverter ac�ve power
according to the set grid voltage.
V(Q): It is used to adjust the inverter reac�ve power
according to the set grid voltage.
This func�on is used to adjust inverter output power
(ac�ve power and reac�ve power) when grid voltage
changes.
Lock-in/Pn 5%: When the inverter ac�ve power is less
than 5% rated power, the VQ mode will not take effect.
Lock-out/Pn 20%: If the inverter ac�ve power is
increasing from 5% to 20% rated power, the VQ mode
will take effect again.
P(Q): It is used to adjust the inverter reac�ve power
according to the set ac�ve power.
P(PF): It is used to adjust the inverter PF according
to the set ac�ve power.
For the detailed setup values, please follow the local
grid code.
Lock-in/Pn 50%: When the inverter output ac�ve power
is less then 50% rated power, it won't enter the P(PF)
mode.
Lock-out/Pn 50%: Lock-out/Pn 50%: When the inverter
output ac�ve power is higher then 50% rated power, it
will enter the P(PF) mode.
Note : only when the grid voltage is equal to or higher
than 1.05�mes of rated grid voltage, then the P(PF)
mode will take effect.
Reserved: This func�on is reserved.It is not
recommended.
A�er se�ng grid parameters
out all changes" and enter password. If the
engineer does not know the password, please
contact your distributor.
- 36 -
select "Lock
, please