Auto-stop check-ups and adjustments
1. Mechanism section
When
the
magnet
keeps
stopping,
and
the
cassette
is
automatically
stopped,
it
is necessary
to
check
the
followings;
1. Check to see whether the belt is broken off.
2. Check
to
see
whether
the
magnet-pulley
and/or
magnet is taken off.
3. Check to see whether the lead switch is switched off.
2. Checking circuits for operation
When
the
rewinding
operation
approaches
the end, the
ejection of the cassette tends to occur.
For this reason, it is necessary to check the control circuits
for operation.
Trouble
Shooting
Electrical circuit
1. Playback tone quality is poor
1) Check the record/playback head for dust.
2) Check the record/playback head for wear.
If worn
excessively,
the
loss of treble
response
will
result.
3) Check wiring for a short-circuit.
Check each transistor for condition.
4) Check the noise reduction circuit for condition.
(This check-up
should
be made
by turning on and off
the switch off the Dolby NR.)
2. Recording tone quality is poor
The playback tone quality of a recorded tape such as the
audition
tape
is good,
but the
recording
by this
unit
produces poor tone quality.
In this case, the unit should be
checked in the following manner.
Cleaning and Oiling
1. Cleaning
Clean
the contact
surfaces
of the record/playback
head,
capstan and pinch roller with the tape.
If the head is dirty, tone quality will be greatly impaired, or
erasure will be imperfect.
Clean
them with a cloth moistened with alcohol, benzine,
or trichloroethylene.
Keep the cabinet free from these chemicals, or the surface
will be dissolved.
2. Oiling
Feed one or two drops of machine oil to the rewind
roller
shaft, pinch
roller shaft and
magnet
pully shaft once
or
twice a year under normal conditions of use.
Avoid
oiling
them
excessively,
or rotation
may
become
irregular because of oil splashes.
1) By monitoring
a music while recording, check the tone
quality.
2) If found poor, check the wiring of the recording system
for a broken wire and short-circuit.
Check transistor for function by measuring voltage.
3) If no
irregalarity
is found,
check
the recording
bias
current.
Also check the oscillation circuit.
4) Check the noise reducing circuit for operation.
3. For other failures, check the unit in the same manner as
other amplifiers.
Mechanism section
If wow and flutter increase, check the following points.
If there is defect in revolving parts, the wow
and flutter
generated
will
increase
in propotion
to
the number
of
revolutions.
Play a 3000Hz test tape, and defective part can be detected
from the sound.
Capstan
Flywheel turns heavily.
(shaft seisure, thrust play etc.)
Pinch roller
or dust)
Angle is incorrect.
Pressure is incorrect.
Capstan belt
Back tension
is too strong.
Motor
Take-up lever arm
Capstan shaft has excessive run-out.
Rough rotation (Deformation scratches,
Back tension is irregular, or back tension
Replace flywheel.
Adjust plastic screw with flywheel holder.
Replace pinch roller.
Clean adjust so that it is parallel to
capstan.
Adjust spring.
Belt has undue run-out.
Replace take-up belt.
Belt is dirty or slippery.
Clean or replace.
Replace supply disc.
Replace back tension spring (under
supply disc), or apply silicon grease.
Motor shaft has undue run-out.
Replace motor.
Motor pulley is oily and dusty.
Clean motor pulley.
Pulley has deflection.
Replace take-up idler arm.
Pulley is stuck.
CD-1740/A/B/E/U