E6581590④ INSTRUCTION MANUAL Optional initial charger MCR-2550 NOTICE 1. Make sure that this instruction manual is delivered to the end user of the optional initial charger. 2. Read this manual before installing or operating the optional initial charger. Keep it in a safe place for reference.
E6581590 Safety precautions On the inverter and in its instruction manual, important information is contained for preventing injuries to users and damages to assets and for proper use of the device. Read the instruction manual attached to the inverter along with this instruction manual for completely understanding the safety precautions and adhere to the contents of these manuals.
Page 3
E6581590 Caution ・Do not install in any area where the unit would be subject to large amounts of vibration. That could result in the unit falling, resulting in injury. Prohibited ■ Wiring Warning ・Do not connect this option to the inverter doesn’t have the DC terminals (PA/+, PC/-). That will destroy both the inverter and the option, and may result in fire.
Note 1: An optional initial charger MCR-2550 is needed for middle- and large-capacity VF-AS1 and VF-PS1 models. Refer to Inverter model on page 5. For 75kW and larger in 200V class and 132kW and larger in 400V class, MCR-2550 are needed parallel connection. Refer to Section 2.2 “Parallel connection for large-capacity inverter “.
■ Basic connection diagram The figure below shows an example of typical wiring with the inverter VFAS1 and VFPS1. Be sure to read the instruction manual of connected inverters for control circuit terminals and parameter settings. MCR-2550 VF-AS1/PS1 (*4) 2Ω...
Page 6
・When using a Harmonic Suppression Unit SB3 as a DC power supply, the optional initial charger may not be required or the inverter may need to be remodeled. Please contact your Toshiba distributor if you like detailed information.
E6581590 2.2 Parallel connection for large-capacity inverter For 75kW and larger in 200V class and 132kW and larger in 400V class, MCR-2550 units are needed parallel connection. ■ Main circuit connection Inverter Note1) DC power MCR-2550 Connector Connector source Motor...
Page 8
(*5): When using a Harmonic Suppression Unit SB3 as a DC power supply, the optional initial charger may not be required or the inverter may need to be remodeled. Please contact your Toshiba distributor if you like detailed information. ■ Operation circuit connection The figure below shows an example of typical wiring with the inverter VFAS1 and VFPS1.
Page 9
E6581590 3. Power supply connection for inverter’s cooling fan In inverter VF-AS1 and VF-PS1 in the table below, it is necessary to supply the 3-phase power supply as inverter cooling fan power supply. When VF-AS1 or PS1 is used with a DC power supply, the Connectors X1 and X4 on the inverter PCBA board have to exchange each other as indicated on the diagrams below.
E6581590 4. Specifications ■ Standard specification Applicable Inverter:TOSVERT VF-AS1,VF-PS1 :DC720Vmax. - 290A Rated Input :AC200~240V-50/60Hz Power supply for operation Item Specification Indoor, Altitude: 1000m or less Use environments Place not exposed to direct sunlight and free of corrosive and explosive gases.