8 Alarms

Operation of the alarms is configurable according to the model. Some or all of the alarms may be displayed
to the user.
When an alarm condition occurs, the drying cycle may be interrupted or paused; in some cases, for safety
reasons, a forced cooling cycle is performed.
In this case, the electronic board, if possible, disconnects the power relay from the heating element and
powers the drum rotation motor with cooling fan. The cycle remains active until the user switches off the
appliance.

8.1 Alarm display during normal operation.

On models with LCD the system displays the family of the current alarm to the user.
First digit: letter "E"
Second digit: the family of the alarm.
Third digit: the alarm number
If we consider, for example, the alarm E53 (communication error between the motor control board and the
main board), the following will be displayed:
First digit: letter "E" (error)
Second-third digit: the number "5 0", i.e. the family of the alarm E53)

8.2 Reading the alarms

To read the last alarm code stored, proceed as follows:
 Access diagnostics mode (see paragraph).
 Turn the programme selector dial clockwise to the tenth position and the display will show the last code
stored.
 To display any other alarms, press the START/PAUSE button.
Try not to stop on position 8, otherwise a dummy alarm is triggered!
First digit: letter "E"
Second digit: the family of the alarm
Third digit: the alarm number
The configuration errors E93 are displayed through the flashing of all LEDs and it is not possible to
access the diagnostics system.
Technical Support - A.D.L.
Alarm 32
52/69