KITA KP47 Series Quick Start Manual

Economical pressure sensor

Advertisement

KP47
Series
PR-0442H 2023/03 Online Version
For your safety, please read the following before using.
Do not use corrosive or flammable gas or liquid with this product.
Please use within the rating pressure range. Do not apply pressure beyond recommended maximum withstand pressure, perma-
nent damage to the pressure sensor may occur.
Do not drop, hit or allow excessive shock. Even if switch body appears undamaged, internal components may be broken and can
cause malfunction.
Turn power off before connecting wiring. Wrong wiring or short circuit will damage and / or cause malfunction.
Do not use in environment containing steam or oil vapor.
This product is not explosion-proof rated. Do not use in atmosphere containing flammable or explosive gases.
Wiring for pressure sensor should avoid power source line and high voltage line. If use in the same circuit, noise may cause
malfunction.
Sensors at end-of-life must be disposed of in accordance with E-Waste regulations of the country/region, NOT disposed of with
regular garbage.
A
SPECIFICATIONS
MODEL
Rated pressure range
Set pressure range
Withstand pressure
Fluid
kPa
MPa
kgf/cm
2
Set
pressure
bar
resolution
psi
inHg
mmHg
Power supply voltage
Current consumption
Switch output
Repeatability
One point set mode
Hysteresis
Hysteresis mode
Window comparator mode
Response time
Output short circuit protection
Display
Indicator accuracy
Switch on indicator
Analog output (Voltage output)
Enclosure
Ambient temp. range
Ambient humidity range
Environment
Withstand voltage
Insulation resistance
Vibration
Shock
Temperature characteristic
Port size
Lead wire
Weight
(with 2 meter lead wire)
※1. Hysteresis value is adjustable within 1 ~ 8 digits for one point set mode and window comparator mode.
We reserve the right to change the specification without prior notice.
Economical Pressure Sensor
KP47C
( Compound Pressure )
-100.0 ~ 100.0 kPa
-103.0 ~ 103.0 kPa
NPN : open collector outputs
Max. Load Current : 80 mA
Max. Supply Voltage : 30 V DC
Residual Voltage : ≤ 1 V
≤ 2.5ms (chattering-proof function: 25ms, 100ms, 250ms, 500ms, 1000ms and 1500ms selectable)
4 digital, 7 segment LCD display ( Red/Green/Orange ) ( Sampling rate : 0.2, 0.5, 1 sec./ time )
Output voltage : 1 ~ 5V ±2.5%F.S. (within rated pressure range)
Linearity : ±1% F.S.
Output impedance : 1 kΩ
Operation : 0 ~ 50 °C, Storage : -10 ~ 60 °C ( No condensation or freezing )
Total amplitude 1.5 mm or 10 G, 10 Hz ~ 150 Hz ~ 10 Hz scan for 1 minute, 2 hours each direction of X, Y and Z
±2% F.S. of detected pressure (25℃) at temp. ( Range of 0 ~ 50℃ )
F1: R1/8", M5 ; F2 : NPT1/8", #10-32 UNF ; F3 : G1/8"(BSPP), M5 ; M5 : M5 female thread
KP47V
( Vacuum Pressure )
0.0 ~ -101.3 kPa
10.0 ~ -103.0 kPa
500 kPa
Filtered air, Non-corrosive / Non-flammable gas
0.1
0.001
0.001
0.01
0.1
1
12 ~ 24 V DC ± 10 %, Ripple ( P-P ) ≤ 10 %
≤ 30mA (with no load)
± 0.3 % F.S. ± 1 digit
Adjustable
Yes
±1% F.S. ±1 digit (ambient temperature : 25±3℃)
Orange Indicator 1 : OUT1 & Orange Indicator 2 : OUT2
IP40
Operation / Storage : 35 ~ 85 % RH ( No condensation )
1000V AC in 1-min ( between case and lead wire )
≥ 50 MΩ ( at 500V DC, between case and lead wire )
100 m/s
( 10 G ), 3 times each in direction of X, Y and Z
2
Ø4 Oil-resistance cable ( PVC ) - 26 AWG ( 0.15 mm
Approx. 67g
KP47P
( Positive Pressure )
-0.100 ~ 1.000 MPa
-0.103 ~ 1.030 MPa
1.5 MPa
0.001
0.01
0.01
0.1
PNP : open collector outputs
Max. Load Current : 80 mA
Max. Supply Voltage : 24 V DC
Residual Voltage : ≤ 1 V
(※1)
Output voltage : 0.6 ~ 5V ±2.5%F.S.
(within rated pressure range)
Linearity : ±1% F.S.
Output impedance : 1 kΩ
) - 4 cores
2
www.kita.com.tw

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KP47 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for KITA KP47 Series

  • Page 1 ) - 4 cores Weight Approx. 67g (with 2 meter lead wire) ※1. Hysteresis value is adjustable within 1 ~ 8 digits for one point set mode and window comparator mode. We reserve the right to change the specification without prior notice. www.kita.com.tw...
  • Page 2: Ordering Information

    30.2 OUT2(White) OUT2(White) 12-24V 12-24V DC (-) (Blue) DC (-) (Blue) 30.2 34.4 DIMENSIONS PA-D Panel adapter Panel adapter 26.3 21.3 30.2 30.2 34.4 M5 female thread Front protective lid 36.3 34.4 21.3 Hex flat : 12 Unit:mm Unit:mm www.kita.com.tw...
  • Page 3: Initial Setting Mode

    *2. This setting mode will not display when output 2 is set to oFF. Press any button *3. Pressure unit is MPa with positive pressure. Pressure unit is kPa with vacuum and compound pressure. Measure mode Power-Save mode *4.Only applicable for Vacuum/Compound. (Main display is off, sub-display will flash " ") www.kita.com.tw...
  • Page 4: Output Type

    Analog output(V) Analog output(V) Analog output(V) Alternately -0.1 1.000 (MPa) - 100.0 100.0 (kPa) -101.3 (kPa) displayed 【NOTE :】 Do not disconnect power when the sub-display and setting value is flashing alternately; otherwise the system cannot store the values. www.kita.com.tw...
  • Page 5 . Applied pressure :Factory setting display value set prior to shipment :Display calibration range Measure mode R.D. (Real Detect) 【NOTE :】1. Setting resolution is ±0.1% R.D. 2.The signal would be changed with analog output after adjusting. www.kita.com.tw...

This manual is also suitable for:

Kp47cKp47vKp47p

Table of Contents