The factory default for supervision is "on".
Two- and four-button fobs do not transmit a supervision signal;
when fobs are programmed, they automatically set supervision
to "off".
Menu 12, Receiver Sensitivity
Menu 12 is used to select the receiver sensitivity .
The sensitivity is also reduced by −6 dB in programming mode
by default. With this menu the sensitivity can be changed to
normal in programming mode.
After exit from the programming mode the sensitivity returns to
normal.
Menu 13, DGP Settings
The DGP can be configured for one of the following modes:
•
Extended 16 zones
•
Standard 13 + 3 zones
•
Extended 32 zones
•
Standard 29 + 3 zones
In the extended modes the DGP reports low battery, long or
smoke supervision, and smoke detector dirty state for each
sensor to the panel separately. This enables the panel to
handle this status information for each zone.
In the standard modes the first three zones of a DGP are
reserved to report supervision, low battery, and smoke detector
dirty state.
For example, on a DGP with address 1 the first three zones
are reserved as follows:
•
Zone 17, smoke sensors dirty. If any of the learned smoke
sensors reports a dirty state, this zone is in an alarm state.
•
Zone 18, supervision. If any of the learned zones is in
short supervision state then this zone alarms. If any of the
learned sensors is in long supervision or smoke
supervision state this zone is in tamper alarm state.
•
Zone 19, low battery. If any zone reports a low battery
fault, this zone is in an alarm state.
Menu 14, Factory Defaults
Menu 14 allows you to reset the wireless DGP to its factory
default settings (extended mode, 16 zones).
Caution:
Resetting clears the entire wireless DGP database.
Supported Sensors
•
TX-1011-03-1 Wireless Slimline door/window contact,
868 MHz GEN2, white
•
TX-1011-03-3 Wireless Slimline door/window contact,
868 MHz GEN2, brown
•
TX-1211-03-1 Universal Transmitter, 868 MHz GEN2,
white
•
TX-1211-03-3 Universal Transmitter, 868 MHz GEN2,
brown
P/N 1070346 • REV 1.0 • ISS 17JAN11
•
TX-2211-03-1 Wireless PIR motion sensor, 868 MHz
GEN2
•
TX-2212-03-1 Mirror PIR, 868 MHz GEN2, Pet Immune
•
TX-2411-03-1 Wireless PIR/MW motion sensor, 868 MHz
GEN2
•
TX-6211-03-1 Wireless optical smoke/heat sensor,
868 MHz GEN2
•
TX-6212-03-1 Wireless optical smoke/heat sensor,
868 MHz GEN2
•
TX-4131-03-2 Wireless 4-button keyfob, 868 MHz GEN2
•
TX-3011-03-1 868 GEN2 2-button pendant panic, white
•
TX-5011-03-1 Shock sensor, 868 MHz GEN2, white
•
TX-5011-03-3 Shock sensor, 868 MHz GEN2, brown
Specifications
Compatibility
Advisor Master control panels: ATS4xxx,
ATS30xx, ATS20xx, ATS10xx (firmware version
04.05.10 or later, the optimal is 04.08.xx or
later).
Advisor Advanced control panels: ATSxxxxA.
868 MHz AM (crystal and SAW) Learn Mode
wireless sensors.
Wireless zones
16 or 32 per DGP (programmable)
Power required
9.5 to 14.4 V
70 mA ±10%
Maximum
1500 m using WCAT52/54, two twisted pairs,
recommended bus
shielded data cable.
distance
Operating
−10 to +55C
temperature
Maximum relative
95%, noncondensing
humidity
Dimensions
16.5 x 11.5 x 4 cm
(L x W x H)
Weight
350 g
Regulatory information
Manufacturer
UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Certification
EN 50131
Security Grade 2, Environmental Class II
Tested and certified by Telefication
1999/5/EC (R&TTE directive): Hereby, UTC Fire &
Security declares that this device is in compliance with
the essential requirements and other relevant
provisions of Directive 1999/5/EC.
2002/96/EC (WEEE directive): Products marked with
this symbol cannot be disposed of as unsorted
municipal waste in the European Union. For proper
recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For more
information see: www.recyclethis.info.
±2%
7 / 8