Summary of Contents for Bucher Hydraulics T Series
Page 1
T Series Hydraulic Units With Single Gear Pumps READ ALL INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
Page 2
Description The hydraulic power units detailed in this document are designed to operate on 3 phase, AC electric power. Each power unit consists of a pressure balanced gear pump, powder coated Unpacking vertical reservoir, Premium Efficiency three Check package for any external signs of damage phase electric motor, P&T ported adaptable that may have occurred during transit then manifold (unloader cavity plugged), return line...
Page 7
All the power units are packaged fully assembled tape. This unit is equipped with SAE O-ring type and tested. Customer is responsible to fill the ports. reservoir with proper level of a quality hydraulic 3. Make sure that the work area and the fluid suitable for use in the intended hydraulic components are clean and free environment.
Page 8
NOTE: Voltage drop increases with the length of power cord. Larger wire diameter may be WARNING required. REPLACE OR REPAIR DAMAGED OR WORN 3. Motor nameplate voltage must be available POWER CORDS IMMEDIATELY. at the motor when it is operating under load. Avoid voltage drop by using adequate wire DO NOT OPERATE UNIT WITHOUT PROPER size.
3. Bleed air from systems 4. Oil temperature is too high 4. Let oil cool well below 130°F Recommended Operating Conditions for T Series Hydraulic Units with Single Gear Pumps Oil Temperature Range: ……………………………………….………………………………………10°F -170°F Recommended Operating Temperature: …………………….………………………………..50°F -130°F Oil Viscosity: Optimum: …………………………………………………………………………..….100 - 350 SUS...
Page 10
HYDRAULIC POWER UNIT PERFORMANCE MODEL Reservoir Nominal Max. Voltage Rated Motor Capacity Flow Pressure Current T55B305MA1RF-01 10GAL.(5.2 1.96GPM 1500PSI 230/460 60 5.72/2.86 USABLE) T55B355RA1SF-01 10GAL.(5.2 1.96GPM 2200PSI 230/460 60 7.62/3.81 USABLE) T55B405RA1SF-01 10GAL.(5.2 1.96GPM 3000PSI 230/460 60 12.4/6.18 USABLE) T61B305AA1FF-01 10GAL.(5.2 2.00GPM 1500PSI...
Need help?
Do you have a question about the T Series and is the answer not in the manual?
Questions and answers