N503 Offline Door Module light indicators ........10 LED functions of the iLOQ NFC Reader .............. 11 Example of wiring for the iLOQ N503 Offline Door Module ..... 12 The setup process ....................13 Setting up the devices .................. 13 Troubleshooting the setup process .............
General notice sign. Indicates particularly important information about the installation and deployment. Read these instructions carefully before installation. This information is to ensure your safety and the long lifetime of the products installed. Use protective gloves. Document ID - XXXXXX iLOQ 5 Series (iLOQ N503 Offline Door Module)
Do not modify the products in any way, except in accordance with these instructions. Installation must only be performed by a qualified technician. Use protective gloves during installation to avoid personal injury. Document ID - XXXXXX iLOQ 5 Series (iLOQ N503 Offline Door Module)
This document contains installation and deployment instructions for the iLOQ N503 Offline Door Module. The iLOQ N503 is a standalone door module that is installed near a door. The iLOQ N503 has no connection to the iLOQ Cloud and the programming can only be done via the iLOQ P55S Programming Key.
• Two (2) years from the start date • Three (3) years from the Supplier’s (iLOQ) original delivery date These conditions are not valid for the iLOQ S10 and the iLOQ 5 Series management software, and mobile software, which have separate conditions.
3.2 Overview of the iLOQ N503 Offline Door Module The iLOQ N503 Offline Door Module is a lock with two relays, and is part of the iLOQ 5 Series Online product family. The features of the iLOQ N503 are limited when compared to other Online products. Time profiles, monitored doors, calendar controls, external tags, key PIN-codes and code access cannot be used.
2. Use the fixing points at the bottom of the screw channel to attach the enclosure to the wall. 3. Close the enclosure cover with the plastic fixing screws, after finalizing the setup and programming. Document ID - XXXXXX iLOQ 5 Series (iLOQ N503 Offline Door Module)
• RS-485 IN: 24V DC Power supply to + and – connections. A / B not used • RS-485 OUT: A / B, DC – Reserved for firmware update • Cylinders: cylinder connections for 2 cylinders. (Cylinders can be connected only when the iLOQ N503 is not programmed) •...
→ A valid key can activate one or two relays at once based on the selected Access right – Relay matrix. See chapter 7.1 for more details. → Relay modes available: Impulse, Switch and Key hold. → Inputs will activate the relays based on the relay mode defined in the iLOQ manager during programming. →...
5. LED functions of the iLOQ NFC Reader Connection status The iLOQ N503 Offline Door Module does not have • Amber light the correct time (RTC) Indicates that the setup was not done correctly. • Red light Wrong device in the bus •...
(see chapter: Programming). The setup has to be performed whenever sub-devices are added to or deleted from the bus. In the case of the iLOQ N503, the bus device can be any iLOQ NFC Reader or C5S.x cylinders.
→ Find the broken device by process of elimination, then change the broken device and perform the setup again → Notice! Can cause problems to the entire bus and other devices of the bus Document ID - XXXXXX iLOQ 5 Series (iLOQ N503 Offline Door Module)
N503 Offline Door Module. 7.1 Adding the iLOQ N503 Offline Door Module as a lock From the system point of view, the iLOQ N503 Offline Door Module is a lock that needs to be added to the system and programmed.
Page 16
4. Attach the preferred access right(s) to the relay(s) by selecting the correct tick boxes in the Relay matrix. 5. Select Transfer to Programming Key. Disconnect the iLOQ P55S Programming Key and program the lock (see chapter: “Programming”) Document ID - XXXXXX...
1. Add the lost key to a blocklist and order the blocklist. 2. Update the latest blocklist version to iLOQ S5 key (with a P55S.1 + MGR or iLOQ Online) or use a S50 Phone key. 3. Use the iLOQ key on the reader connected to N503.
8. Using the iLOQ N503 Offline Door Module unprogrammed Connected C5S.x cylinders will control the Relays of the iLOQ N503 Offline Door Module. • A valid key in the L1 connected cylinder will activate the K1 for 8 seconds • A valid key in the L2 connected cylinder will activate the K2 for 30 seconds...
To continue to programming, the previous steps have to be successfully done and the iLOQ N503 power has to be turned ON. Make sure that the devices are still connected, the setup has been completed and the iLOQ P55S Programming Key is disconnected and has the programming packet as described in the chapter “iLOQ Manager”.
1. Add the lost key to a blocklist and order the blocklist. 2. Update the latest blocklist version to iLOQ S5 key and use it on the N503 or use a S50 Phone key. → Make sure that the key used to transfer the blocklist has the correct main zone defined Replacing a broken iLOQ N503 with a new one: 1.
Decommissioned iLOQ products containing electronics and circuit boards, such as iLOQ Cylinders, iLOQ Keys, net bridges, door modules, key and NFC Readers, and relay cards, must be recycled at an electrical and electronic equipment collection point.
Need help?
Do you have a question about the 5 Series and is the answer not in the manual?
Questions and answers