The exclamation point triangle is used to alert the user to important operating or maintenance instruc- tions. Macro-Tech MA-24X6 & 36X12 Power Amplifiers FCC COMPLIANCE NOTICE This device complies with part 15 of the FCC rules. Operation is subject to the following...
Macro-Tech MA-24X6 & 36X12 Power Amplifiers Crown International, Inc. Issued By: Crown International, Inc. 1718 W. Mishawaka Road Elkhart, Indiana 46517 U.S.A. Competent Body’s Name and Address: Technology International (Europe) Limited 41-42 Shrivenham Hundred Business Park, Shrivenham, Swindon, Wilts, SN6 8TZ...
Macro-Tech MA-24X6 & 36X12 Power Amplifiers 1 Welcome Congratulations on your purchase of a Macro- 1.1 Features ® Tech dual level professional power amplifier. • Your amplifier has a separate high-power and medium-power channel, making it ideal for biamplified systems. The Macro-Tech 24x6 combines one channel of a Macro-Tech 2400 with one channel of a Macro-Tech 600.
Important Safety Instruc- tions found at the beginning of this manual. page 6 Macro-Tech MA-24X6 & 36X12 Power Amplifiers 2.2 Install Your Amplifier CAUTION: Before you begin, make sure your amplifier is disconnected from the power source, with power switch in the “off”...
Macro-Tech MA-24X6 & 36X12 Power Amplifiers 2 Setup 2.4 Choose Input Wire and Connectors Figure 2.3 shows connector pin assignments for balanced wiring, and Figure 2.4 shows connec- tor pin assignments for unbalanced wiring. NOTE: Custom wiring should only be performed by qualified personnel.
Macro-Tech MA-24X6 & 36X12 Power Amplifiers 2 Setup 2.6 Wire Your System This section describes the most common way to install the Macro-Tech 24X6 and 36X12. Each model is designed for biamplified systems and includes both a high-power and a medium- power channel.
If you are unsure of the output voltage of your AC mains, please consult your electrician. page 10 Macro-Tech MA-24X6 & 36X12 Power Amplifiers 2.8 Startup Procedure Use the following procedure when first turning on your amplifier: 1.
Macro-Tech MA-24X6 & 36X12 Power Amplifiers 3 Operation 3.1 Precautions Your Macro-Tech Series amplifier is protected from internal and external faults, but you should still take the following precautions for optimum performance and safety: 1. Before use, your amplifier first must be con- figured for proper operation, including input and output wiring hookup.
B. Level Control Rotary detented level control, one per channel. page 12 Macro-Tech MA-24X6 & 36X12 Power Amplifiers C. Signal/IOC Indicator Green LED, one per channel. Dual-pur- pose indicator illuminates to indicate the presence of input signals; flashes brightly with a 0.1-second hold delay to indicate a...
Macro-Tech MA-24X6 & 36X12 Power Amplifiers 3 Operation 3.3 Back Panel Controls and Connectors G. Power Cord 120 VAC, 60 Hz units have a 20-amp (12 AWG) line cord with a grounded NEMA 5-15P plug. Input Sensitivity Switch See Section 8 for AC power usage.
14 Macro-Tech MA-24X6 & 36X12 Power Amplifiers This level of protection enables Crown to increase output transistor utilization while greatly increasing amplifier reliability.
Macro-Tech MA-24X6 & 36X12 Power Amplifiers 4 Advanced Features and Options 4.1.4 Transformer Thermal Protection All Macro-Tech amplifiers have transformer thermal protection. It protects the power sup- plies from damage under the rare conditions of transformer temperatures rising too high. A...
• Listen Bus allow easy connection to an audio monitoring system. page 16 Macro-Tech MA-24X6 & 36X12 Power Amplifiers 4.3.3 Input Sensitivity Switch The Input Sensitivity Switch is located inside the PIP compartment at the back of the ampli- fier (Figure 4.1). It is set at the factory to 0.775 volt for rated output into 8 ohms.
Macro-Tech MA-24X6 & 36X12 Power Amplifiers 5 Troubleshooting 5.1 Indicators The front panel has several helpful indicator LEDs (Figure 5.1). The amber Enable indicator is provided to show the amplifier has been turned on (or enabled) and that its low voltage power supply and forced-air cooling system are working.
Page 18
Macro-Tech MA-24X6 & 36X12 Power Amplifiers 5 Troubleshooting Figure 5.2 ODEP and Signal/IOC Indicator States page 18 Operation Manual...
Macro-Tech MA-24X6 & 36X12 Power Amplifiers 6 Theory of Operation Each channel is powered by its own power transformer, T100 or T200. Both channels share TF-1, a low voltage transformer. The sec- ondary outputs of each transformer are full- wave rectified by heavy duty bridge rectifiers and are filtered by large computer grade capac- itors.
Macro-Tech MA-24X6 & 36X12 Power Amplifiers 7 Specifications Minimum Guaranteed Power Power in watts per channel,1 kHz, 0.1% THD Channel 1 2 ohms per ch. 4 ohms per ch. 8 ohms per ch. Channel 2 2 ohms per ch. 4 ohms per ch.
Page 22
Weight Shipping Center of gravity is 6 inches (15.2 cm) behind the front mounting surface page 22 Macro-Tech MA-24X6 & 36X12 Power Amplifiers Macro-Tech 24X6 See Figure 7.3 2, 4, 8, 16 ohms 83:1 ±6% or 38 dB ±0.5 dB (Ch. 1, .775V sensitivity) 124.6:1 ±6% or 42 dB ±0.5 dB (Ch.
• Duty cycle of continuous speech is 10%. • Duty cycle of infrequent, short duration paging is 1%. page 24 Macro-Tech MA-24X6 & 36X12 Power Amplifiers Here are the equations used to calculate the data presented in Figures 8.1 and 8.2:...
Macro-Tech MA-24X6 & 36X12 Power Amplifiers 8 AC Power Draw and Thermal Dissipation Operation Manual Figure 8.1 Macro-Tech 24X6 Power Draw, Current Draw and Thermal Dissipation at Various Duty Cycles Figure 8.2 Macro-Tech 36X12 Power Draw, Current Draw and Thermal Dissipation at Varioius Duty Cycles...
Crown website at www.crownaudio.com, or by calling Crown Customer Service. page 26 Macro-Tech MA-24X6 & 36X12 Power Amplifiers 9.2.2 Factory Service To obtain factory service, fill out the service infor- mation page found in the back of this manual and send it along with your proof of purchase and the defective unit to the Crown factory.
Macro-Tech MA-24X6 & 36X12 Power Amplifiers 10 Warranty SUMMARY OF WARRANTY Crown International, 1718 West Mishawaka Road, Elkhart, Indiana 46517-4095 U.S.A. warrants to you, the ORIGINAL PURCHASER and ANY SUB- SEQUENT OWNER of each NEW Crown product, for a period of three (3) years from the date of purchase by the original purchaser (the “warranty...
Page 28
We will remedy any defect, regardless of the rea- son for failure (except as excluded), by repair, page 28 Macro-Tech MA-24X6 & 36X12 Power Amplifiers WORLDWIDE EXCEPT USA & CANADA replacement, or refund. We may not elect refund DISCLAIMER OF CONSEQUENTIAL AND...
Macro-Tech MA-24X6 & 36X12 Power Amplifiers Owner’s Name : ________________________________________________________________________________________________________________________________________________________________ Shipping Address: ______________________________________________________________________________________________________________________________________________________________ Phone Number: ________________________________Fax Number: ________________________________ Email ________________________________________________________________________________ Model: __________________________________________________________________________________ Serial Number: ________________________________________________________________________ Purchase Date : ________________________________________________________________________________________________________________________________________________________________ (Be sure to describe the conditions that existed when the problem occurred and what attempts were made to correct it.)
Page 30
Macro-Tech MA-24X6 & 36X12 Power Amplifiers This page intentionally left blank. page 30 Operation Manual...
Page 31
Macro-Tech MA-24X6 & 36X12 Power Amplifiers This page intentionally left blank. Operation Manual page 31...
Need help?
Do you have a question about the Macro-Tech MA-24X6 and is the answer not in the manual?
Questions and answers
How to replace the power cord on a macro tech 24x6 amp