Advertisement

Quick Links

OptiXstar B671G Quick Start
Issue
04
Date
2023-10-30
HUAWEI TECHNOLOGIES CO., LTD.

Advertisement

Table of Contents
loading

Summary of Contents for Huawei OptiXstar B671G

  • Page 1 OptiXstar B671G Quick Start Issue Date 2023-10-30 HUAWEI TECHNOLOGIES CO., LTD.
  • Page 2 Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS"...
  • Page 3 Security Declaration Vulnerability Huawei's regulations on product vulnerability management are subject to “Vul. Response Process”. For details about the policy, see the following website: https://www.huawei.com/en/psirt/vul-response-process For enterprise customers who need to obtain vulnerability information, visit: https://securitybulletin.huawei.com/enterprise/en/security-advisory Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 4: Table Of Contents

    4.4 Indoor T-Rail Installation (15mm Thick) ........................14 5 Removing the Device ......................... 18 6 Connecting Cables to the B671G ....................19 7 B671G indicator description...................... 22 8 Technical Specifications ......................24 9 FAQs .............................. 25 Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 5: Device Appearance

    Exercise caution when pressing the reset button. After the device is reset, Internet access may become unavailable. If you cannot access the Internet after the reset, contact your service provider for help. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 6 OptiXstar B671G Quick Start 1 Device Appearance Use a power adapter that complies with related safety standards or has passed the CE certification. Otherwise, the device may be damaged. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 7: Networking Scenario

    Automatic networking between the main FTTR and sub FTTR, and plug-and-play In the FTTR for SME scenario, sub FTTRs must be used together with a main FTTR and FTTR ADUs. Figure 2-1 Huawei FTTR gigabit enterprise networking Issue 04 (2023-10-30)
  • Page 8: Determining The Installation Position

    Figure 3-1 Installation reference diagram When determining the installation position, comply with the following rules:  Minimize the number of obstacles (such as walls) between the device and STAs. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 9 Far away from other electronic devices (such as microwave ovens) that may cause antenna interference For a device with a built-in antenna, the distance requirement for the antenna is the distance requirement for the device. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 10: Installing The Device

    When fixing the mounting bracket, ensure that the arrows of point upwards. Attach the mounting bracket against the wall and adjust its position properly. Mark positions of the mounting holes with a marker, as shown in the following figure. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 11 Hammer the expansion tubes into the holes until the expansion tubes are flush with the wall. Attach the mounting bracket to the wall, and use the Phillips screwdriver to fasten three expansion screws into the expansion tubes to secure the mounting bracket to the wall. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 12 Align the rubber feet at the rear of the device with the installation holes on the mounting bracket, and fasten the device as shown in the figure. When you hear a click, the device is secured to the lock position. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 13: Indoor T-Rail Installation (7Mm Thick)

    Lead the steel wire ropes through the group J holes on the mounting bracket and the holes on the ceiling in sequence, tighten the ropes, and use a hex key to tighten the heads of ropes. The mounting bracket is secured to the ceiling. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 14 OptiXstar B671G Quick Start 4 Installing the Device Drill a cable hole on the ceiling in front of the mounting bracket. Take cable protection measures for the cable hole. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 15: Ceiling-Mounted/Wall-Mounted Installation (15Mm Thick)

    50 N.  When the tightening torque of a screw reaches 3.5 N· m, the screw still properly works, without crack or damage on the wall. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 16 Connect and arrange the cables. For details, see 6 Connecting Cables to the B671G. If cables need to be routed through the ceiling, the drilling method shown in Figure 4-3 is recommended. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 17 If the device is installed in a scenario with strong vibration, use M3x12 screws to secure the device to the mounting bracket to prevent the device from falling off due to vibration. In normal scenarios, you do not need to install these screws. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 18: Indoor T-Rail Installation (15Mm Thick)

    T-rail supported by the mounting bracket. The following uses a flat-edge T-rail of 24 mm as an example. The mounting brackets must be installed on the main rail. Partially tighten the M3x6.2 set screw to the T-rail brackets. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 19 T-rail is tightened. Secure the M3x8 screw through hole 24 marked in the figure, and secure T-rail mounting bracket b. Tighten the M3x6.2 set screw for installing the T-rail mounting bracket. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 20 After the device is installed, ensure that the ejector lever is in position to prevent the device from falling off. Ensure that the installation space meets the specified requirements to facilitate future maintenance. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 21 If the device is installed in a scenario with strong vibration, use M3x12 screws to secure the device to the mounting bracket to prevent the device from falling off due to vibration. In normal scenarios, you do not need to install these screws. Figure 4-6 Fixing device using screws Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 22: Removing The Device

    Slide the device in the reverse direction to unlock it. Figure 5-1 Removing the B671G If screws are installed, remove the screws and then follow the preceding steps to remove the device. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 23: Connecting Cables To The B671G

    Connects to a photoelectric composite cable for GPON upstream port transmission. Figure 6-2 shows how to connect a photoelectric composite cable. To remove a photoelectric composite cable, press the button and remove it, as shown in Figure 6-3. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 24 Cables should be parallel or separated using dedicated separators.  The cables must be bound tightly and neatly, and the cable sheaths must not be damaged. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 25 Cable ties are bound neatly facing the same direction, and those at the same horizontal line must be in a straight line. Cable tie tails should be cut smoothly and evenly.  Labels or nameplates must be attached to the cables after they are installed. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 26: B671G Indicator Description

    V500R023C00 and later versions support this indicator state. This indicator state can be used to quickly identify the sub FTTR. If the WeFTTR Assistant app does not support this function, update the app version. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 27 OptiXstar B671G Quick Start 7 B671G indicator description If the indicator is off, the device is not powered on or the LED indicator is turned off. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 28: Technical Specifications

    8 Technical Specifications Technical Specifications Item Specifications Dimensions (H x W x 38 mm x 200 mm x 200 mm –10° C to +50° C Operating temperature Operating humidity 5%–95% RH, non-condensing Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.
  • Page 29: Faqs

    Press RESET button with a needle for longer than 10 seconds to restore factory defaults and reset the B671G. If the indicator is off and then is lit, the system restores successfully. Issue 04 (2023-10-30) Copyright © Huawei Technologies Co., Ltd.

Table of Contents