15.
CHANNEL
TO
CHANNEL
CROSSTALK
(Refer to Fig. 43)
Band
poss
Oscilloscope
cR.osc
Attenuoter
KHz
-10dB
RECORD
mode
PLAY
BACK
mode
LINE
IN
Tape
Figure 44
1) Set Mode Selector Switch (SW-8) at "CASSETTE
PLAY".
2) Set BASS
Control
(R209,
R210) and TREBLE
Control
(R211,
R212) in the central positions.
3) Set R.I.F. Switch (SW-W) at "A".
'
4) Insert a blank cassette into the unit and input -10 dB, 1kHz signal to LINE IN jack and record only in one channel
in the maximum
position of VOLUME
control (R207, R208).
5) Playback
the tape after recording and connect
8 ohm
dummy
to Speaker jack (SO704,
SO705)
and adjust
VOLUME
Control so that voltage at both ends of dummy
becomes 3.3V.
Henceforth,
output voltage through 1kHz
Band Pass Filter is to be 0 dB.
6) Adjust VOLUME
Control of the blank channel to the position of VOLUME Control of the recorded channel
mechanically.
7) Measure voltage at both ends of 8 ohm dummy through 1kHz Band Pass Filters.
It is normal if deviation to
to output voltage compared with the above 5 is over 25 dB.
16.
MEASUREMENT
OF
CURRENT
CONSUMED
(Refer to Fig. 44)
CR. OSC
RECORD mode
8 ohm
Dummy
AC. Ammeter
110/220/240V
50Hz
Figure
45
20