4.4,
Head Base Stroke Adjustment
Refer to Fig. 4.7.
Note:
Before
you
conduct
"Head
Base Stroke Adjust-
(1)
(2)
(3)
(4)
ment", adjust with a "Tilt Check Gauge'' to insure
freedom from tilt on the record/playback head.
Load a Stroke Check Gauge M-9038 (DA09038A) in
the N-480Z.
Set the N-480Z in Play mode.
Check
to insure
whether
the
"P"
pointer on the
Stroke Indicator locates between 2 lines as marked on
the Stroke Check Plate.
If the record/playback head stroke is noted to be mis-
aligned,
adjustment
can
be made
by moving
the
stroke adjuster assembled
in the head base assembly
(either forwardly or backwardly),
4.5.
Tape
Guides
Adjustment
and
Erase Head Stroke
Adjustment
Remove
Head Mount
Base Ass'y referring to item 2.22.
Refer to Figs. 4.8 and 4.9.
(1)
(a)
(b)
(c)
(d)
(e)
(2)
(a)
(b)
(c)
(d)
(e)
Supply Tape Guide Height Adjustment
Load
an
EH
Stroke
Check
Gauge
M-9051
(DAO-
9051A) in the N-480Z.
Set the N-480Z in Play mode.
Slide the Supply Tape Guide Check Bar down against
the supply
tape guide, thus check can be made on
supply tape guide height.
If the supply
tape guide is misaligned, the Supply
Tape Guide Check Bar will not come into the supply
tape guide. If such is noted, turn to adjust the height
adjustment
nut A till the Supply Tape Guide Check
Bar is accepted by the supply tape guide.
If the above
are insured, set the N-480Z
in Pause
mode, then in Play mode to see whether adjustments
are appropriately
made.
If not, (b) through
(e) will
have
to be repeated
till satisfactory results are ob-
tained.
Take-up Tape Guide Height Adjustment
Load
an
EH
Stroke
Check
Gauge
M-9051
(DAO-
9051A) in the N-4802Z.
Set the N-480Z in Play mode.
Slide
the
Take-up
Tape
Guide
Check
Bar down
against the take-up tape guide, thus check can be
made on take-up tape guide height.
If the take-up tape guide is misaligned, the Take-up
Tape Guide Check Bar will not come into the take-up
tape guide. If such is noted, turn to adjust the height
adjustment nut C till the Take-up Tape Guide Check
Bar is accepted by the take-up tape guide.
If the above
are insured, set the N-480Z
in Pause
mode, then in Play mode to see whether adjustments
are appropriately
made.
If not, (b) through (e) will
have to be repeated till satisfactory results are ob-
tained.
aL
Play Mode
(3)
(a)
(b)
(c)
(d)
Fig. 4.7
Erase Head Stroke Adjustment
Load
an
EH
Stroke
Check
Gauge
M-9051
(DAO-
9051A) in the N-480Z.
Set the N-480Z
in Play mode,
thus check
can be
made
on erase head stroke through the EH Stroke
Indicator.
Check
to insure whether
the erase
head
surface is
aligned with red line on the EH Stroke Indicator. If
not,
adjust the erase
head
stroke
by loosening
2
screws
B that assemble
erase
head
and erase head
plate.
After
completion
of adjustment,
2 pcs. of screws
shall be locked with lock tight paint.
Supply
Tape Guide
Check
Bar
Fig. 4.8
Take-up
Tape Guide
Check
Bar
EH Stroke
Indicator