Care And Cleaning; Troubleshooting - Glacier bay HD67896W-1101 Use And Care Manual

Single-handle standard kitchen faucet
Table of Contents

Advertisement

Available languages

Available languages

Operation (continued)
2
Removing the quick connector
If it is necessary to remove the quick connector
(1), squeeze the tabs (2) on the quick connector
and then pull down to disconnect.

Care and Cleaning

To clean, wipe down with a damp cloth and dry with a towel.
Do not use abrasive cleaners, steel wool, or harsh chemicals when cleaning this faucet, or the warranty will
be voided.

Troubleshooting

NOTE: Refer to the service parts section in this manual for
a detailed drawing showing the location of the parts listed
below.
Problem
There are leaks from the
handle.
The aerator has an
irregular or reduced
water ow.
The water will not shut off
completely.
Possible Cause
The bonnet nut has come loose and/or the
washer is dirty or damaged.
The aerator is dirty or mis- tted.
The rubber seat and spring is dirty or
broken.
Squeeze
1
6
2
Pull
down
1
Solution
Use wrench to retighten the
bonnet nut suf ciently.
Clean or replace the washer.
Remove the aerator and
check for debris.
Ensure that the rubber washer
is properly installed.
Remove the cartridge to check
the rubber seat and spring.
Clean or replace.