Panasonic Lumix S-R24105 Service Training Manual

Interchangeable lens for digital camera

Advertisement

Quick Links

Service Training Manual
Specifications
INTERCHANGEABLE LENS FOR DIGITAL CAMERA
"LUMIX S 24-105 mm F4 MACRO O.I.S."
Mount
Focal length
Lens construction
Aperture type
Maximum aperture
Minimum aperture value
Angle of view
Recording range
Maximum image magnification
Image stabiliser
Filter diameter
Maximum diameter
Overall length
Mass (Weight)
Dust and splash resistant
Recommended operating
temperature
Permissible relative humidity
S-R24105
Component Repair
Leica Camera AG L-Mount
f=24 mm to 105 mm
16 elements in 13 groups
(2 aspherical ED lenses, 2 aspherical lenses, 1 UED lens, 2 ED lenses)
9 diaphragm blades/circular aperture diaphragm
F4.0
F22
84°(Wide) to 23°(Tele)
0.30 m (0.98 feet) to ∞ (from the focus distance reference line)
0.5×
Yes
77 mm
Φ84 mm (3.3 inch)
Approx. 118 mm (4.6 inch)
(from the tip of the lens to the base side of the lens mount)
Approx. 680 g (1.4991 lb)
Yes
-10 ℃ to 40 ℃ (14 ℉ to 104 ℉)
10%RH to 80%RH
ⓒ Panasonic Corporation 2021 Unauthorized copying and distribution is a violation of law.
Ver.1.1
Internal use only

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic Lumix S-R24105

  • Page 1 Approx. 680 g (1.4991 lb) Dust and splash resistant Recommended operating -10 ℃ to 40 ℃ (14 ℉ to 104 ℉) temperature Permissible relative humidity 10%RH to 80%RH ⓒ Panasonic Corporation 2021 Unauthorized copying and distribution is a violation of law.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS PAGE 1 Service Navigation ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ 1.1. Introduction ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ 1.2. Important Notice ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ 1.2.1. Overview of Cleaning and Replacing parts ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ 1.2.2. How to treat LENS P.C.B. UNIT ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ 2 Exploded View ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ 2.1. Exploded View of Lens Unit ・ ・ ・ ・ ・ ・ ・ ・ ・ ・...
  • Page 3: Service Navigation

    1 Service Navigation 1.1. Introduction This manual contains technical information, which allow service personnel's to understand and service this model. Please place an order using the parts list and not the drawing reference numbers. 1.2. Important Notice Perform lens cleaning and repair in the clean room (class 10,000) since lens is delicate product and it dislikes a dust. 1.2.1.
  • Page 4: Exploded View

    2 Exploded View 2.1. Exploded View of Lens Unit B209 B206 1st Lens B210 Frame Unit B204 B207 B200 B203 B201 B211 B208 B213 B212 B205 B229 B230 B202 B215 B231 B214 B232 Lens P.C.B. Unit B226 B220 B222 B219 B227 B223 B221...
  • Page 5: Replacement Parts

    3 Replacement Parts ・Parts marked with [IMBU] in the remarks column are supplied from SLBD-IMBU. ・Others are supplied from PAVCX Ref.No. Part No. Part Name & Description Remarks DVQL1138Z CE/WEEE LABEL VQL1W22 TEN YEARS LABEL 1 GK LOU4SR24105CSFCZ LENS UNIT 1 [IMBU] 300 - 302 DVMH1197Z...
  • Page 6: Service Jigs & Tools

    600mm x 800mm Rp-Chart M-size SUKZ000035 300mm x 400mm Lens Cleaning Kit VFK1900BK Collimeter RFKZ0422 Master Body Purchased locally DC-S1R (Panasonic) Tweezers Purchased locally Plastic or bamboo (Do not use metal) Nipper Purchased locally Tripod Purchased locally Locking glue Purchased locally...
  • Page 7: Maintenance

    5 Maintenance 5.1. Dust / Dirt on the outer casing part(s) 1. Blow off the dust first, then sweep out the dust from narrower spaces with soft cleaning brush. 2. Wipe up the outer casing part with the dry fuzz-free cloth. 5.2.
  • Page 8: Disassembly And Assembly Procedures

    6 Disassembly and Assembly Procedures 6.1. Disassembly Procedures 6.1.1 Disassembly Flowchart Lens Unit 1 Shading Frame L Mount Mount Rubber 3 Shading Sheet 4 Rear Frame Unit Mount Contact Unit Lens P.C.B. Unit 6 Ring Mount Base Unit Attention For optical axis adjustment only,perform No.10 and No.11. 10 Decoring Unit Filter Ring 7 1st Lens Frame Unit...
  • Page 9: Disassembly Procedure

    6.1.2. Disassembly Procedure Important Notice: - Perform lens disassembly in the clean room (class 10,000 / Federal Standard 209D) since lens is delicate product and it dislikes a dust. < Preparation > - Set the zoom position to WIDE end (24mm). - Put the Lens so that the line of zoom comes towards you.
  • Page 10 6.1.2.3. Removal of Shading Sheet 1. Remove Shading Sheet Shading Sheet 6.1.2.4. Removal of Rear Frame Unit 1. Remove 3 Screws (D) Screw(D) 2. Remove Rear Frame Unit BLACK 6.1.2.5. Removal of Lens P.C.B. with Mount Contact Unit 1. Disconnect 5 connectors 2.
  • Page 11 6.1.2.6. Removal of Ring Mount Base Unit Screw(F) 1. Remove the Screw(F) 2. Remove Zoom Drive Pin Zoom Drive Pin SILVER Encoder brush 3. Remove 4 Screws (G) 4. Remove Ring Mount Base Unit Screw(G) <Caution> - Care about Encoder brush (red circle). (Tips) rotate the ring toward TELE side a little to prevent it from coming off.
  • Page 12 6.1.2.7. Removal of 1st Lens Frame Unit 1. Remove 3 Screws(H) 2. Remove 1st Lens Frame Unit 1st Lens 3. Remove 3 1st Cam Pins Frame Unit Front side 5.8mm Screw(H) BLACK Rear (body) side <Note> - At this illustration, the lens of front side is upward.
  • Page 13 6.1.2.9. Removal of 3rd Lens Frame2 Unit and 5th Lens Frame Unit Pull out the FPCs to set it free. 3rd Lens 1. Remove 3 Screws (J) Frame2 Unit 2. Remove 3 pcs of 2-5 Cam Pin 3. Remove 3rd Lens Frame2 Unit 4.
  • Page 14: Assembly Procedure

    6.2. Assembly Procedure 6.2.1 Assembly Flowchart 3rd Lens Frame2 Unit 5th Lens Frame Unit Cam Barrel Unit 2 2nd Lens Frame Unit 3 1st Lens Frame Unit 4 Ring Mount Base Unit Mount Contact Unit Lens P.C.B. Unit 6 Rear Frame Unit 7 Shading Sheet L Mount Mount Rubber...
  • Page 15: Assembly Procedure

    6.2.2. Assembly Procedure Important Notice: - When tightening the screw, use a torque driver (RFKZ0542) with specified torque described in each step. - When assembling, please be careful not to mix dust into the lens. - Regarding the screws, It is not necessary to return to exactly the same position as long as the same specification. 6.2.2.1 Installation of the 5th Lens Frame Unit and 3rd Lens Frame2 Unit 1.
  • Page 16 It is easier to work with 3 Lens Unit and 5 Lens Unit attached. <Note> Peel off the double-sided tape backing paper.
  • Page 17 6.2.2.2. Installation of the 2nd Lens Frame Unit 1. Install 2nd Lens Frame Unit to Cam Barrel Unit with adjusting the rotational phase as the 2-5 Cam Pin penetrates. 2. Install 2-5 Cam Pin for 2nd Lens Frame Unit and tighten screw (H) by using the torque driver with specified torque.
  • Page 18 6.2.2.3. Installation of the 1st Lens Frame Unit 1. Install 1st Cam Pin to Cam Barrel Unit 1st Lens with adjusting the rotational phase Frame Unit as the 2-5 Cam Pin penetrates. Install 1st Lens Frame Unit to Cam Barrel Unit with adjusting the rotational phase ▲...
  • Page 19 6.2.2.4. Installation of the Ring Mount Base Unit 1. Install 1st Lens Frame Unit with Cam Barrel Unit to Ring Mount Base Unit with adjusting the rotational phase screw (G) as shown in the figure while pulling out the FPC via the Hole.
  • Page 20 6.2.2.5. Installation of Lens P.C.B. with Mount Contact Unit 1. Install Lens P.C.B. with Mount Contact Unit to Screw (E) Ring Mount Base Unit so that the screw of the Lens P.C.B. match. 2. Tighten Screw (E) Gently. - Screw(E) × 3 Insert FPC to connector of Lens P.C.B.
  • Page 21 6.2.2.7. Installation of Shading Sheet 1. Install Shading Sheet to Ring Mount Base Unit Mount Contact The matte surface is the back side. 6.2.2.8. Installation of L Mount 1. Install Mount Rubber 2. Install L Mount 3. Tighten screw (C) by using the torque driver with specified torque. - Screw(C) ×...
  • Page 22: Inspection And Adjustmen

    7 Inspection and Adjustment 7.1. Matrix Table of Necessary Inspection and Adjustment when Replacing Parts The table shows necessary inspection and adjustment when replacing parts. Necessary Inspection and Adjustment Simple Simple Replacement Part Resolution Electrical Resolution Real Time Adjustment Inspection Adjustment - - - - - -...
  • Page 23: Matrix Table Of Necessary Inspection And Adjustment When Cleaning

    7.2. Matrix Table of Necessary Inspection and Adjustment when Cleaning The table shows necessary inspection and adjustment when cleaning. Necessary Inspection and Adjustment Simple Simple Cleaning Portion Resolution Electrical Resolution Real Time Adjustment Inspection Adjustment - - - - - - - - - Outside surface of the Lens ◎...
  • Page 24: Flowchart Of Inspection And Adjustment

    7.3. Flowchart of Inspection and Adjustment 7.3.1. Flowchart of Inspection Check for Defective Parts and Internal Dust Disassembly Replacement or Cleaning Assembly Electrical Adjustment Initial : All item Second Time : BF only Setting to Simple Resolution Inspection "7.4.1.1" , in detail - Check the brightness and settings of camera TELE end...
  • Page 25: Flowchart Of Adjusument

    7.3.2. Flowchart of Adjusument Disassembling Decoring Unit and Filter Ring Removal glue around 3 Adjustment Pins/Screws Setting to Simple Resolution Real Time Adjustment ( "7.4.1.2" , in detail ) - Check the brightness TELE end and settings of camera - Begin again after Simple Resolution body and test chart disassembly/assembly...
  • Page 26: Procedure Of Inspection And Adjustment

    7.4. Procedure of Inspection and Adjustment 7.4.1. Equipment and Chart Setting 7.4.1.1 Setting to Simple Resolution Inspection (2) Checking Chart USB cable (1) LED lamps (4) PC Software (3) Lens and Master Body(DC-S1R) Install LED lights left and right symmetrically as uneven illumination does not occur.
  • Page 27 7.4.1.2 Setting to Simple Resolution Real Time Adjustment (2) Checking Chart (5) Monitor HDMI cable USB cable (1) LED lamps (4) Capture Board (6) PC Software (3) Lens and Master Body(DC-S1R) Install LED lights left and right symmetrically as uneven illumination does not occur.
  • Page 28: Checking Chart Image

    7.4.2. Checking Chart Image <Preparation> - Checking Chart (Part No. SUKZ000059) that consisted of 5 charts No.1 - No.5. and 4 black charts. - White plastic matte board /Size: 1,440mm(W) x 960mm(H) or above Guide Line - Length: 500mm or more - Thickness: 5mm or more No.2 No.5...
  • Page 29: Master Body(Dc-S1R) Setting And Position

    7.4.3. Master Body(DC-S1R) Setting and Position 7.4.3.1 Master Body(DC-S1R) Setting - Cancel the Initial Setting - Set the function parameter to below setting Setting Item Setting value Mode dial A (Aperture-Priority AE Mode) Aperture F 4 (Maximum aperture) 【S】([AFS]) Focus mode Image stabilizer White balance AF mode...
  • Page 30 For more accurate checking, hang the hand glass installed from the upper part of the center of the Checking Chart to the string down, and adjust it to come to the chart center. And If the lens of oneself reflecting in the mirror is displayed in the center of the LCD monitor, placing is correctly.
  • Page 31: Lens Unit Setting

    7.4.4. Lens Unit Setting - Set the function parameter to below setting Setting Item Setting value AF/MF switch O.I.S. switch 7.4.5. PC Software 7.5.4.1 Required PC Specification - OS : Windows 10 - Processor :Pentium 4/M or equivalent - Memory :512 MB RAM - Display :1,024 ×...
  • Page 32: Simple Resolution Inspection

    7.4.6. Simple Resolution Inspection Simple Resolution Inspection is useful for all models. 7.4.6.1 Procedure of Simple Resolution Inspection ② ④ ① ③ Click “Shooting” button to take a photo. *Before taking a photo, focus the chart by AF ON button of DC-S1R. Click the folder icon to set the default folder path of photo for checking.
  • Page 33 ⑥ ⑦ Select the photo file you want to check. Click “OK”. ⑧ Click “OK”, then this dialog will close and start measurement.
  • Page 34 Show results in graphic indicator - If all the graphic indicators show “OK”, it passes the inspection. After that, make sure by visual check. - If there is/are “NG” in graphic indicators, the lens does not meet standard. -> (Before servicing) If lens is damaged, replace it by new lens. ->...
  • Page 35: Simple Resolution Real Time Adjustment

    7.4.7. Simple Resolution Real Time Adjustment The 1st Lens Frame Unit is adjustment available in real time. Rotate the three adjustment pins while monitoring bar graphic indicators. See details in below. 1st Lens Frame Unit Torx driver (RFKZ0609) Peel off the glue around the pins so that adjustment can be conducted.
  • Page 36: Electrical Adjustment

    7.4.8. Electrical Adjustment Make Electrical Adjustment using PC with Adjustment Software. As for Adjustment conditions/procedure, consult the "Adjustment Manual" which is available in Adjustment Software. Note: - Download the software package from TSN. - The first time to implement all item - The second time to implement the only BF Adjustment 7.4.9.
  • Page 37 DecoRing Unit Gluing Filter Ring Torque 10.0 ± 1.0 N ・cm RP Chart L-Size 600x800mm RP Chart M-Size 300x400mm (SUKZ000034) (SUKZ000035) (Notice) SUKZ000034 / SUKZ000035 are no longer available due to production discontinuation SUKZ000068 / SUKZ000069 are substitution for Rp-chart.
  • Page 38: Revision History

    8 Revision History Ver. Date History 2021.05.14 ・First Issue 2023.11.6 1. Correction of 1st lens figure, addition of precaution 2. Change of parts No. 3. Addition of the chart parts No. 4. Addition of detailed assembly/disassembly description 5. Addition/Correction of detailed adjustment description...

This manual is also suitable for:

Lumix s 24-105 mm f4 macro o.i.s

Table of Contents