Table 8-10: Measurement Options
Show Connection
Points
Display Text
Caliper Size
Connection Point
Color
Caliper Color
Caution: Some caliper sizes/colors, font sizes or dot colors may not appear clearly on the image
Note: To ensure the caliper modifications have been activated, switch imaging modes after
Worksheet Settings apply to the Report Worksheet.
Enable QA Review
OB Measurement
Order...
Author Settings...
Pregnancy Weeks
Heart Rate Beats
Fertility Cascade #
Export Precision
Chapter 8: System Setup
Select to display the connection points (dotted line) between the linear
calipers.
Allows the selection of one (1) of three (3) measurement label font size
options: Small, Medium and Large.
Allows the selection of one (1) of three (3) caliper size options: Small,
Medium and Large.
Allows the selection of the color of the caliper connection points (dots)
between the linear calipers. The default is turquoise.
Allows the selection of the color of the caliper end points. The default is
turquoise.
screen, stored image or printed/recorded image. To ensure clear visualization of the caliper,
label font and connection points, Ultrasonix recommends setting the caliper graphics to at
least Medium.
exiting the Setup menus.
Appends editable Billing and QA Review fields to all Reports.
Note: Any Report/Worksheet opened/created during/prior to this setting
being selected will not include the Billing and QA options.
Allows user to change the order in which OB Measurements are
presented on the touch screen, in a Worksheet (onscreen) and in a
Report (printed).
OB Measurements available for reordering are: BPD, OFD, HC, AC, FL,
HL, GS, CRL, NT, YS, CxLength, UL, TL, TTD, CEREB, APTD, FTA,
FHR, Umb A, Umb A-PI, MCA and MCA-PI.
Note: Refer to
Refer to
Note: It is not possible to create user-defined Cardiac tables, nor can
factory default tables be modified or deleted.
Defines the number of weeks used to calculate the EDD based on LMP.
Range: 35–45 weeks.
Number of beats used to measure the HR and FHR on an M-Mode and
Doppler Trace. Range: 1–7 beats.
Defines the number of times the user must repeat a follicle measurement
before the system automatically moves to the next follicle. Range: 1–3
measurements.
Sets the decimal placement for some types of third party reporting
packages. Range: 0–6. The default is 2 decimal places.
Appendix H: Glossary
Appendix F
for a complete list of Author Settings.
00.040.388, Revision F
8-32
for details on these acronyms.
SonixOP User Manual