Bosche zippcube S Operating Manual

Bosche zippcube S Operating Manual

Volume measuring system

Advertisement

Quick Links

BOSCHE
Volume measuring system
R
zippcube
Operating manual
- Translation of the original -
(keep for future use)
Version - Version -
Last revised: 2023-11-20

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the zippcube S and is the answer not in the manual?

Questions and answers

Summary of Contents for Bosche zippcube S

  • Page 1 BOSCHE Volume measuring system zippcube Operating manual - Translation of the original - (keep for future use) Version - Version - Last revised: 2023-11-20...
  • Page 3 This manual has been created on: 2023-11-20 Copyright Bosche GmbH & Co. KG retains all rights for this document. Copying, disclosure to third parties or use of its contents are forbidden without our express approval © 2023 Type plate example zippcube M...
  • Page 5 The manufacturer's contact data is listed on the reverse of the title page. If you have any queries or problems, please contact the manufacturer without delay. Note If you have any questions for Bosche GmbH & Co. KG, please have the serial number to hand. Version -...
  • Page 6: Table Of Contents

    5.3 Battery switch....................22 5.4 Transport trolley .................... 22 6 Troubleshooting ....................23 6.1 System restart ....................23 6.2 Contacting customer service................. 24 6.3 Information needed when contacting customer service ........ 24 Version - BOSCHE Weighing Systems Page 2 2023-11-20...
  • Page 7 8.2 Data of the optional transport trolley ............. 27 8.3 Object dimensions..................27 8.4 Scope of delivery................... 28 9 Spare parts ......................29 9.1 Overview of spare parts ................29 10 Declaration of Conformity ................30 Version - BOSCHE Weighing Systems Page 3 2023-11-20...
  • Page 8: Safety

    • Danger to limb and life of operators, third persons and animals staying in the vicinity of the device. • Danger to the device and other assets of the owner/user • Danger to the efficient operation of the device. Version - BOSCHE Weighing Systems Page 4 2023-11-20...
  • Page 9: Safety Symbols In This Manual

    Note Always specify the serial number of your display for all questions, orders or jobs. This will facilitate the communication with the manufacturer and prevents error during editing your request. Version - BOSCHE Weighing Systems Page 5 2023-11-20...
  • Page 10: Inappropriate Use

    • Stop device operation, if the device or the connection line is damaged of have a malfunction. 1.6.2 Danger of Damages • Only connect the device to suitable load cells (see chapter 3.6 “Interface”). • Never use pointed objects to actuate the device keys. Version - BOSCHE Weighing Systems Page 6 2023-11-20...
  • Page 11: Liability And Warranty

    The BOSCHE company offers a restricted warranty for components, which became faulty due to strain or material faults. The warranty starts with the date of delivery. The BOSCHE company retains the right to repair or replace components. Repair work executed during the warranty period will not extend the period of warranty.
  • Page 12: Description

    Measurement port with light grid (T = transmitter, R = receiver) Measurement plate - consisting of 8 mm toughened safety glass with a 2 mm scratch-resistant plexiglass guard. Industrial PC with display Version - BOSCHE Weighing Systems Page 8 2023-11-20...
  • Page 13: Measuring Principle

    • The glass plate must be clean and undamaged. • Always use Perspex screen to avoid scratches on the glass plate • Place the measurement objects on carefully. • Nothing must interrupt the light beams except for the measurement object. Version - BOSCHE Weighing Systems Page 9 2023-11-20...
  • Page 14: Industrial Pc

    2 | Description Volume measuring system zippcube® Industrial PC The Bosche 15-inch industrial PC is used as the display unit. You operate the industrial PC using a touchscreen. The industrial PC has the following interfaces: • two USB 2.0 ports •...
  • Page 15: Transport, Installation, Connection | 3

    Separately dispose of a defective battery according to the national and local regulations on environmental protection and recycling. Do not treat a battery as standard waste. Please dispose of via a waste management company. Version - BOSCHE Weighing Systems Page 11 2023-11-20...
  • Page 16: Installation And Connection

    Pay attention to the centre of gravity. Step 1 Put the volume and weight measurement system tilt-free on an even, level surface and align it exactly. Step 2 Release/remove all the transport retainers (e.g. cable ties). Version - BOSCHE Weighing Systems Page 12 2023-11-20...
  • Page 17: Connection

    Plug in the volume and weight measurement system to the mains (if operating without a rechargeable battery = standalone use). Step 3 Insert the charged batteries (optional equipment for mobile use, for example). Version - BOSCHE Weighing Systems Page 13 2023-11-20...
  • Page 18: Transportation Positions

    Push the measurement port to the display. Step 3 Secure the position of the measurement port (using cable ties, for example). Step 4 Pack the volume and weight measurement system appropriately and securely to prevent damage in transit. Version - BOSCHE Weighing Systems Page 14 2023-11-20...
  • Page 19: Transportation Using The Optional Transport Trolley

    Release the two brakes on the casters of the transport trolley. Step 3 Carefully push the transport trolley to the new measuring location. Step 4 There, secure the transport trolley by applying the two brakes again. Version - BOSCHE Weighing Systems Page 15 2023-11-20...
  • Page 20: Operation

    Step 4 Check that the weight display of the empty scale shows 0.00 kg. Step 5 „Zero“ the scale, if the weight display of the empty scale does not show 0,00 kg. Version - BOSCHE Weighing Systems Page 16 2023-11-20...
  • Page 21: Battery Switch (Optional)

    Operation | 4 Battery switch (optional) The Bosche Battery switch enables mobile working with Bosche weighing sys- tems. The weighing system is powered by two batteries, in which first a battery is being discharged. Is this discharged or removed unexpectedly from the device, the battery switch switches to the second battery.
  • Page 22: Communication Protocol

    BAT.POW:100<CR><LF> Status power supply unit from 0 – 100% BAT.ST1:100<CR><LF> Status battery one from 0 – 100% BAT.ST2:100<CR><LF> Status battery two from 0 – 100% BAT.LOW<CR><LF> Both batteries empty. System is switched off. Version - BOSCHE Weighing Systems Page 18 2023-11-20...
  • Page 23: Measuring An Object

    When measuring, the light grid strips must be free from foreign objects. You must not make any changes to the measuring frame (this could impair meas- uring precision and functioning). Note The weighing software is described in separate operating manual. Version - BOSCHE Weighing Systems Page 19 2023-11-20...
  • Page 24: Testing Equipment Monitoring

    Close the weighing software by touching the X. The system closes the software and you can see the Windows desktop. Step 2 Switch off the industrial PC by shutting down Windows. Step 3 Pull out the mains plug . Version - BOSCHE Weighing Systems Page 20 2023-11-20...
  • Page 25: Optional Equipment | 5

    After this, place it on the precision scale for fine adjustment. Additional USB ports As an option, three additional USB ports are available that are each protected by a screw-on cap. Version - BOSCHE Weighing Systems Page 21 2023-11-20...
  • Page 26: Battery Switch

    A transport trolley for the zippcube volume and weight measurement system is available as an option. The volume and weight measurement system is bolted on the transport trolley. The transport trolley has two fixed casters without brakes and two casters with parking brakes. Version - BOSCHE Weighing Systems Page 22 2023-11-20...
  • Page 27: Troubleshooting

    Close the weighing software by touching the “X“ area. Step 2 Pull out the mains plug or remove the batteries. Step 3 Wait for a few minutes until the system is safely deenergisedt. Step 4 Restart the system. Version - BOSCHE Weighing Systems Page 23 2023-11-20...
  • Page 28: Contacting Customer Service

    6 | Troubleshooting Volume measuring system zippcube® Contacting customer service Bosche GmbH & Co. KG Reselager Rieden 3 49401 Damme Phone +49 (0)5491 9996890 Fax +49 (0)5491 9996899 E-mail info@bosche.eu Information needed when contacting customer service Opersting company Information Name of your company...
  • Page 29: Maintenance And Care

    Step 5 Task two people with inserting the glass plate back in. Step 6 Rub all the surfaces with a dry cloth. Attention No moisture must enter the volume measuring system. Version - BOSCHE Weighing Systems Page 25 2023-11-20...
  • Page 30: Maintenance, Servicing

    7 | Maintenance and care Volume measuring system zippcube® Maintenance, servicing Only trained service engineers who have been authorised by Bosche are allowed to open the volume measuring system. Danger Before opening the volume measuring system, you must ensure that it has been safely deenergised and disconnected from the mains.
  • Page 31: Technical Data | 8

    Volume measuring system zippcube® Technical data | 8 Technical data Data of the volume measuring system Value/Unit Feature zippcube S zippcube M zippcube L Lenght 825 mm 1306 mm 1676 mm Widht 655 mm 895 mm 1105 mm Hight 590 mm...
  • Page 32: Scope Of Delivery

    8 | Technical data Volume measuring system zippcube® Scope of delivery Component Note Volume measuring system zippcube Operating Manual Switch battery (optional) 3 Makita rechargeable batteries with charger 19 V power supply Version - BOSCHE Weighing Systems Page 28 2023-11-20...
  • Page 33: Spare Parts | 9

    You can order the spare parts that are listed below from your dealer or directly from Bosche’s Customer Service Department. Overview of spare parts You can purchase the components below as spare parts from Bosche’s Cus- tomer Service Department: 2 2 2 2 2 3 1.
  • Page 34: 10 | Declaration Of Conformity

    Photobiological safety: EN 50581 :2012 IEC 62471 :2006 (EN 62471 :2008) Unterzeichnet für und im Namen von Bosche: Signed for and on behalf of: Signé pour et au nom de: Ondertekend voor en namens: Firmado por y en nombre Damme, 27/6/2017 Dipl.
  • Page 36 BOSCHE GmbH & Co. KG 05491 999 689 0 Reselager Rieden 3 Fax 05491 999 689 9 49401 Damme www.bosche.eu Germany info@bosche.eu...

This manual is also suitable for:

Zippcube mZippcube l

Table of Contents