Connecting the CAN connection cable Connection Commissioning Capturing cross traffic for door opening Setting ED parameters for operation with radar sensors Troubleshooting Open sensor on the wall Evaluate errors and rectify faults Disassembly and disposal Radar sensor M A01 060590 45532/16707 - 2023-04...
ED 250 operators (firmware V2.9.000) for swing This document describes the mounting and doors from dormakaba. commissioning of the radar sensors M A01 with ED 2.2 Personnel qualification connection board CAN for the ED 100/250 operators of swing doors and the integration of the sensors and operators into the EntriWorX EcoSystem.
3 Product description 3.2 UKCA Declaration of Conformity Sensor M A01 is a radar sensor that is mounted on the hinge side and the opposite side to the hinge in the This chapter is only an extract from the full middle of the door.
Status LED function display CAN socket Position Meaning Note Recess Place a screwdriver in the recess to lift the hood off the base. Long slot Guide the CAN connection cable through the long slot. 060590 45532/16707 - 2023-04 Radar sensor M A01...
Determine the mounting positions on the hinge side and the opposite side to the hinge centrally above the door. M A01 2. Comply with the installation heights according to ED 100/250 M A01 the table. 3. Avoid letting the ED operator shadow the sensor. Parameter Value Installation height from 2.0 m to 4.0 m...
Assembly Instruction 4.3 Mounting the sensor above a 2-leaf door M A01 M A01 ED 100/250 ED 100/250 Passive door leaf Active door leaf 060590 45532/16707 - 2023-04 Radar sensor M A01...
4.4 DIP switch setting 4.5 Set the hole pattern for the sensor dormakaba recommends setting the DIP switch before the sensor is mounted on the wall. Observe the installation heights according to the information in the tables, see “Mounting theMounting If the position of the DIP switches is changed, carry out a CAN reset (Cr) (set Cr = 1).
4.7 Install individual components The tilt angle depends on the mounting height 4.7.1 Mounting the radar sensors Mounting heights Tilt angle dormakaba recommends setting the DIP switches before the sensor is mounted on the 30° wall. 45° The action steps in this manual refer to operation with 2 sensors.
Observe the alignment of the board. The terminal name can be found on the board. Unplug the plug for this. Color Function Connection terminals code White +24V DC Green CAN-H Yellow CAN L Brown Radar sensor M A01 060590 45532/16707 - 2023-04...
Signal input safety sensor hinge side Test output + 24 V Signal input safety sensor opposite side to the hinge Test output Signal input night/bank Signal input impulse outside Signal input pulse inside 060590 45532/16707 - 2023-04 Radar sensor M A01...
4,5 m 4,5 m With a parameter value of 1 , cross traffic is detected from the right in order to open the door. This applies to the area marked in green. Radar sensor M A01 060590 45532/16707 - 2023-04...
With the CAN reset, the hold-open time is general opening time of the door. If the door opens automatically set to “0” if at least 1 radar sensor M A01 slowly, it opens sooner. If it opens faster, it opens is connected.
This affects the bus board CAN shows the following errors. communication with the radar sensor. Check the CAN connection cable and the device. Actuate Power on on the ED drive. Radar sensor M A01 060590 45532/16707 - 2023-04...
The product must not be disposed of in domestic waste. Dispose of the product in an environmentally friendly manner at the collection points set up for this purpose. Refer to the statutory regulations for your country. 060590 45532/16707 - 2023-04 Radar sensor M A01...
Need help?
Do you have a question about the M A01 and is the answer not in the manual?
Questions and answers