11.4 Cooling suction pressure curves
outdoor temp.
(humidity 46%)
DB/WB
10℃
15℃
20℃
25℃
30℃
35℃
38℃
40℃
43℃
1550
1350
1150
950
750
550
350
cooling suction pressure.table
21/15℃
794
802
810
852
897
906
954
1049
1154
cooling suction pressure and temp.curves
10℃ 15℃ 20℃ 25℃ 30℃ 35℃ 38℃ 40℃ 43℃
performance curves
indoor temp.
27/19℃
929
938
957
967
1018
1028
1060
1166
1259
outdoor temp.(DB/WB)
51
Performance and curves diagrams
35/24℃
1079
1090
1101
1124
1135
1195
1219
1341
1462
21/15℃
27/19℃
35/24℃
Domestic air conditioner