8 | KEY DESCRIPTION OF THE WEEKLY-TIMER CENTRAL CONTROLLER
7.2.
Key instructions of the weekly-timer central controller
Table.7-1
KEY NAME
Press the ON/OFF button. All air conditioners will be shut down if they are running, on the contrary, they will be started
up.If you press the button for less than 5 seconds, the startup mode is the last running mode of the air conditioner. If you
press the button for more than 5 seconds, the startup mode is cooling, high Speed,24 degrees.
Press the"SET" button, and then select "set single"or " set all". "set single" indicates to set the parameter (such as mode/
temperature/ Fan speed/ weekly timer) of an selected air conditioner, "set all"indicates to set the parameter of all air
conditioners controlled by the central controller.
Press the "query" button to query the running condition of the air conditioner. such as on/off, temperature setting, indoor
temperature, running mode and Fan speed. Press "up", "down", "Left" and "right" to select the air conditioner that you want
to query.
When querying or setting the indoor unit, press the "up" to select the indoor unit to be set or queried.
When querying or setting the indoor unit, press "down" to select the indoor unit that you want to set or query.
When querying or setting the indoor unit, press "Left" to select the indoor unit to be set or queried. In setting the weekly
timer, it is used for selecting the day of the week and the time of startup and shutdown.
When querying or setting the indoor unit, press "right" to select the indoor unit to be set or queried. In setting the weekly
timer, it is used for selecting the day of the week and the time of startup and shutdown.
When querying the indoor unit, press the "Add" button to query more parameter of the indoor unit. In setting the indoor
unit, its used for increasing the set temperature. In weekly timing setting use for increasing time.
Table.7-2
KEY NAME
When querying the indoor unit, press the "Reduce"button to query more parameter of the indoor unit. In setting the indoor
unit, use to decrease the set temperature. In weekly timer mode, use to decrease set time.
In setting the indoor unit, it is used for setting the running mode of the indoor unit which includes Automation,Cool, Heat,
Fan Only, Dry and Off.
In setting the indoor unit, it is for setting the fan speed of the indoor unit which includes high speed, medium speed, low
speed and automatic speed.
In setting the indoor unit, it is for setting the swing-function of the indoor unit. The running mode is selected
between"swing-on"and" swing-off'.
When setting, press the "Lock" button to lock the remote controller of all or single indoor unit. Press the "Query" button
and hold under the main page, then repress the" Lock" button again to lock the keyboard of the central controller; press the
"Mode" button and then repress the "Lock" button to lock the running mode.
The central controller re-scans the indoor unit in the network after power off.
Under the main page, press the "Program" button to set the weekly timer of "single indoor unit" or "all indoor units". Press
the "Query" button and hold, and then press the "Program" button to query the weekly timer parameters of the indoor unit.
Table.7-3
KEY NAME
Under the main page, press the "Weekly" button to start up or shut down the weekly timer function.
Under the main page, press the "Time" button for 5 seconds to enter the time-modifying status, and then press "Add"
or "Reduce"button to modify the time. Press "Left" or "Right" to select minute/ hour/ day/ month/ year. Finally press the
"Confirm" button to save the modification.
Save data and send the command required to the indoor unit, such as setting the mode of the air conditioner.
Cancel the last operation and return to the last interface.
6720862458 (2017/05)