INSTALLATION & OPERATION MANUAL Air to water heat pump - mono series TIСA PRO LLC 141014, Russia, Moscow oblast, Mytishchi, Very Voloshinoy Ulitsa, office 705 and 805 Tel.: +7(495)822-29-00 E-mail: info@tica.ru www.tica.ru...
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) Contents Contents ........................1 I. Check List ......................1 II. Must-read for Users .................... 2 III. Product Overview....................4 1. Overview ........................ 4 2. Outside View and Structure ................4 3.
I. Check List Inspect the following items against the list after unpacking the product, and make sure that the unit comply with the information on the nameplates. For any queries, consult your local distributor or call TICA hotline. Name Instruction for Use...
● Do not put your finger or other objects into a running equipment as it may cause personal injuries. ● If any parts are soaked in water, contact TICA's personnel to check or repair it before use again. ● Never drink or use the water in the unit for daily lives.
Page 5
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) Warning: The power supply of this equipment must be reliably grounded before use. Within close proximity of the air to water heat pump chiller, there must be a well-functioning floor drain.
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) III. Product Overview 1. Overview The inlet and outlet of the unit water pipes are connected to the air side products. In this way, the unit is able to offer hot/cold water to each air side product, which could facilitate heat exchange in the room and therefore heat/cool the room.
Cooling capacity: At rated water flow rate,outdoor air temperature 35⁰ C DB; LWT 7⁰ C. Due to the continuous improvement and innovation of TICA products, the product models, parameters and performance in this document are subject to changes without prior notice. The parameters indicated on the nameplate should prevail.
At low ambient temperatures, in particular, when the ambient temperature is below 0° C, the water system of the unit will most likely fail to work properly due to frozen water pipes. By utilizing TICA's unique multi-grade anti-freezing technology, our unit could automatically determine when to enter or exit anti-freezing protection under powered on, and therefore guarantee steady operation of the unit to the greatest extent.
If you find any damages or you have other problems, please immediately contact with TICA. * Before installation, make sure that the unit power is consistent with its electricity meter capacity and power cords.
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) 2. Unit Installation and Connection Diagram Air dischar ge Flexible valve connector Gate valve Gate Electric Electric Gate Electric Gate valve Gate two-way two-way valve two-way Water valve valve valve...
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) protection is reported, it is recommended to be greater than 1.5m³/h).If it is less than the minimum value, you can lower the differential pressure bypass valve set value, or the pump set the lowest gear higher.
Page 13
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) TECA120BEDIC 100L TECA140BEDIC 120L TECA160BEDIC 140L TECA180BERIA 150L TECA200BERIA 160L TECA220BERIA 170L The water volume of the cooling/heating water system should be checked separately, and both should meet the requirement of the minimum water volume mentioned above.
Page 14
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) Model Circulating water flow Internal pressure Unit external Remarks drop (m) lift (m) Provided with water pump TECA120BEDIC 2.06 10.0 Provided with water pump TECA140BEDIC 2.41 Provided with water pump TECA160BEDIC 2.75 Provided with water pump...
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) select and install an external water pump, please consult the water pump manufacturer.Generally, keep the external water pump and built-in water pump running in series to increase the lift, but note that the selected external pump must match the built-in pump in terms of its characteristic flow curve.
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) The installation space of the unit is shown as follows. (1) TECA120/140/160BEDIC、TECA180/200/220BERIA Air inlet Air inlet For wire > 300 and piping Support maintenance > 600 Base Air outlet 5.
Page 17
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) Installation of expansion bolts should comply with relevant standards and requirements. The bracket must be horizontal upon installation, and could bear the unit's weight whenever it is operating, installed or repaired.
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) 1. Set up a canopy to avoid snow 2. The unit should stay above the snow that might accumulate on the ground Wall mounting is not recommended for a noise- or vibration-sensitive place, as the noise and vibration may pass into the room.
Page 19
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) The connection pipes have to withstand pressure of not less than 1 MPa. The connection pipes have to withstand temperature of not less than 70° C. ...
Page 20
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) After the pressure test, insulate the inlet and outlet pipes properly, lest heat losses, condensation or freezing may occur. Precautions Decide whether or not to install the energy storage tank, external water pump, expansion tank, water purifying or demineralized water treatment device, pressure gauge and thermometer according to the on-site conditions.
Page 21
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) Maintenance space must be reserved for the expansion tank. Water pressure and air tightness test should be carried out according to relevant standards and manufacturer's requirements after installation of expansion tank. Automatic air discharge valve Automatic air discharge valves are used to discharge air out of the water system so that the unit works properly.
Page 22
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) excessive pressure may break the pipes. The test pressure shall comply with the relevant standard and shall be no less than 0.5MPa. Keep the test pressure for 1h and the pressure drop shall be no more than 0.05MPa. In the meantime, check to make sure that all pipes and their joints are free from leakage.
Page 23
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) Note During water supply process, when water is released from air discharge valve, it is considered that air discharge is done and it is time to close air discharge valve. While this could never fully discharge the air in the system, the remaining air could be discharged from automatic air discharge valve after the system operates for some time.
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) 7. Electrical Installation (1) Instructions on electrical wiring Notes: The unit must use the special power supply, and the supply voltage must comply with the rated voltage. The minimum starting voltage of the unit must be kept above 90% of the rated voltage, the voltage must be within ±...
Page 25
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) Power cord For the specifications of power cord, please refer to the following form. Cable diameter (mm Circuit breaker (Plastic insulation and sheathed wire) Model Power supply capacity (A) Phase line Neutral line Earth line...
Page 26
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) Electrical principle diagram TECA120/140/160BEDIC FAN 2 FAN 1 EXV 1 EXV 2 EXV 3 M M M M M M XT 2 X1 5 A CO MP FA N 1 X2 8 A X2 9 A...
Page 27
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) 2)TECA180/200/220BERIA FA N2 FA N1 EX V1 EX V2 EX V3 M M M M M M X15A CN 1 2 FAN1 X28A X29A X30A X24A X23A X22A X21A X20A CN 1 1 PF C - L2...
Page 28
TICA's dedicated FCU thermostat can be used for RS485 communication with the main board. The figure below shows the wiring of indoor air side products and the ODU when TICA's dedicated FCU thermostat is used to implement the interlocked control of indoor air side products and the IDU.
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) ODU main board 2# FCU thermostat 3# FCU thermostat 1# FCU thermostat It is necessary to enable the FCU interlock through the DIP switch of the unit. ON of S1-3 indicates FCU interlocking enabled.
Page 30
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) (2) Trial operation After power is applied to the unit for over 24 hours, press “ON/OFF” button on the wired controller to turn on the unit. ...
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) V. Operation and Use of Wired Controller 1. Screen description Icon Name Function Query 1) Query errors on the main interface. 1) Tap Menu to enter the function menu on the default interface. Menu 2) Tap Menu to return to the preceding level of menu on the setting interface or query interface.
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) controller. In the operation status area, "Stop" is displayed if the unit is shut down. If the water pump is started, the water pump symbol ( ) is displayed; if the water pump is not started, the symbol is not displayed. If the word "Ambient"...
Page 33
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) 7) Pressure sensor value 1) Operating mode settings, including mode, temperature and humidity 2) Configuration parameter settings, including centralized control parameter Modify User Parameters 3) Date and time settings 4) Unit timing settings Modify Maintenance A password is required.
● For any abnormalities or faults occurring during operation, note to contact TICA or report them to your local service agency. Never attempt to repair them on your own. ● Before maintenance, make sure to disconnect the circuit breaker of the unit.
Page 35
If failing to discharge water normally, contact TICA or contact local service agency. If water flows out of the unit continually, close ball valve on inlet and outlet pipes, and then contact TICA or contact local service agency.
Page 36
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) made. If left idle for too long, make sure to do a thorough check and cleaning of the unit and its water system before it can be started. ...
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) VII. Common Faults Code Fault description Cause Handling Method E001 Inadequate water flow Water flow switch disconnected Check the water flow switch wiring External interlocking SW E002 External interlocking Check external interlocking SW wiring disconnected...
Page 38
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) wires 2. Temperature sensor is damaged 2. Replace temperature sensor 1. Temperature sensor gets loose 1. Check its wiring and tighten them Water outlet temperature wires E026 fault 2.
Page 39
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) 2. Compressor is damaged 2. Replace the compressor 1. Four way valve stuck 1. Check whether the valve be stucked Four way valve abnormal in E040 2. Four way valve wire connection heating 2.
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) VIII. After-sales Service If repair and maintenance service is needed, please contact TICA. Notes: Improper maintenance or repair may cause water leakage, electric shock or fire. When you need to move or reinstall the unit, please contact TICA for consultation.
The service life is specified by TICA. The environmental protection service life is not equivalent to the service life of safe use.
Page 42
Installation Manual of Inverter Type Household Air Source Heat Pump Chiller (Heat Pump) due to technical reasons, and it will be improved gradually along with technical progress in the future. *: It indicates that the environmental protection service life of the battery matched with the product is 2 years. The number in this identification indicates that the environmental protection service life of the product under the normal use status is 15 years.