WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Toshiba shall not be liable for any damages, losses, expenses or costs, if any, incurred in connection with or as a result of use of any information or data provided herein.
IMPORTANT NOTICE User's Guide Contents: Install Autodesk DWF Viewer Internet Explorer Settings Operating Environment Functions Provided on Each Drawing Page Using with Network Install Autodesk DWF Viewer Autodesk DWF Viewer is necessary to view drawings and to activate the functions of this system. Please download and install.
Page 4
for Internet Explorer 7 for Windows Vista...
Operating Environment : Pentium III or higher recommended Monitor : 1024 x 768 or higher resolution recommended Mouse : A mouse with wheel recommended : Microsoft Windows 2000 SP4 / XP / Vista Browser Microsoft Internet Explorer 6.0 / 7.0 Drawing viewer : Autodesk DWF Viewer 6.0 / 7.0 * Use the software following respective license terms and conditions.
Page 6
ZEUS Engine Program Ver.2 and ZEUS Service Manual Ver.2 are to be modified. Perform the procedure described below. Preparation 1. Run the program file zuesFPch.exe to install the program file for File-Path to the Local PC. -> Download zeusFPch_setup.zip (2.3MB) 2.
Page 7
1. Whenever changing the file-path of both ZEUS Engine Program and ZEUS Service Manual to use with network, pay the attention to set the "Exchange to" column that should have a proper relation between ZEUS Engine Program and ZEUS Service Manual with referring the following. Run the zeusFPch and set "Exchange to"...
Page 8
4. Run the ZeusFPch to change the path in the ZEUS Service Manual Ver2. 5. Set unzipped ZEUS Service Manual in the created folder in the server to the "Target Folder", and then press "START". (This procedure is required whenever placing service manual.) Confirmation Confirm that service manual on the server can be operated normally by client PC.
Page 9
Through WEB, ver. 6.5 has been released but with it, the linking function in this manual may not work properly. If ver. 6.5 has been installed, uninstall it and reinstall ver. 6.0. To get ver. 6.0, click the icon, or contact to the nearest Toshiba Service Centre for further assistance. Freezing windows opened (Cannot close the open windows) This may happen occasionally.
Corporation recognizes environmental protection as a key management tasks, and is doing its utmost to enhance and improve the quality and scope of its environmental activities. In line with this, Toshiba proactively promotes Green Procurement, and seeks to purchase and use products, parts and materials that have low environmental impacts.
LEAD-FREE SOLDER This product is manufactured using lead-free solder as a part of a movement within the consumer products industry at large to be environmentally responsible. Lead-free solder must be used in the servicing and repair of this product. WARNING: This product is manufactured using lead free solder.
SAFETY INSTRUCTION WARNING: BEFORE SERVICING THIS CHASSIS, READ THE "SAFETY PRECAUTION" AND "PRODUCT SAFETY NOTICE" INSTRUCTIONS BELOW. Safety Precaution WARNING: SERVICING SHOULD NOT BE ATTEMPTED BY ANYONE UNFAMILIAR WITH THE NECESSARY PRECAUTIONS ON THIS RECEIVER. THE FOLLOWING ARE THE NECESSARY PRECAUTIONS TO BE OBSERVED BEFORE SERVICING THIS CHASSIS.
10. Touch current check. (After completing the work, measure touch current to prevent an electric shock.) Plug the AC cord directly into the AC outlet. Do NOT use an isolation transformer for this check. Connect a measuring network for touch currents between each exposed metallic part on the set and a good earth ground such as a water pipe.
Page 14
characteristics. These characteristics are often passed unnoticed by a visual inspection and the protection afforded by them cannot necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in this manual and its supplements; electrical components having such features are identified by the international hazard symbols on the schematic diagram and the parts list.
SAFETY INSTRUCTION Handling the LCD Module Safety Precaution In the event that the screen is damaged or the liquid crystal (fluid) leaks, do not breathe in or drink this fluid. Also, never touch this fluid. Such actions could cause toxicity or skin irritation. If this fluid should enter the mouth, rinse the mouth thoroughly with water.
Page 16
result in discoloration or stripes. Immediately remove any type of fluid from the screen. 5. Glass is used in the panel, so do not drop or strike with hard objects. Such actions can damage the panel. 6. CMOS-LSI circuitry is used in the LCD module, so avoid damage due to static electricity.
Page 17
10. When transporting the LCD module, do not use packing containing epoxy resin (amine) or silicon resin (alcohol or oxim). The gas generated by these materials can cause loss of polarity.
Page 18
U02A U01A POWER MAIN U03A AC SW U04B RMT U04A LED...
SCHEMATIC DIAGRAM Precaution WARNING: BEFORE SERVICING THIS CHASSIS, READ THE "X-RAY RADIATION PRECAUTION" FOR DIRECT VIEW CTV ONLY, "SAFETY PRECAUTION" AND "PRODUCT SAFETY NOTICE" OF THIS MANUAL. CAUTION: The international hazard symbols " " in the schematic diagram and the parts list designate components which have special characteristics important for safety and should be replaced only with types identical to those in the original circuit or specified in the parts list.
ADJUSTMENT Service Mode Entering to Service Mode 1. Press button once on remote control. ↓ 2. Press button again and hold button down. ↓ Service Mode display 3. While holding the button, press MENU button on TV set. Displaying the Adjustment Menu Press MENU button on TV.
Page 87
Key Function in the Service Mode The following key entry during display of adjustment menu provides special functions. CAUTION: Never try to perform initialization unless you have changed the memory IC. Test signal selection button (on remote control) PROGRAMME (on TV or remote control) Selection of the adjustment items Volume +/- (on TV or remote control)
Page 88
COLX COLX COLN COLN SHPX SHPX SHPN SHPN RCUT RCUT GCUT GCUT BCUT BCUT RDRV RDRV GDRV GDRV BDRV BDRV OSRC RCUT OFF SET COOL OSGC GCUT OFF SET COOL OSBC BCUT OFF SET COOL OSRD RDRV OFF SET COOL OSGD GDRV OFF SET COOL OSBD BDRV OFF SET COOL OSRC RCUT OFF SET NATURAL...
Page 89
3) Change ID data into MODEL ID to initialize by pressing + or -, refer to "MODEL ID TABLE". For example, if initializing 40LV655P, change MODEL ID into "0x02". Note: MODEL ID is hex value. 4) Execute initialization of the memory.
Test Signal Selection Every pressing of button on the remote control changes the built-in test patterns on screen as described below in Service Mode. Picture Signal Red raster Green raster Blue raster All Black All White Self Diagnostic Function 1. Press "9" button on remote control during display of adjustment menu in the Service...
Page 91
Mode. The diagnosis will begin to check if interface among IC's is executed properly. 2. During diagnosis, the following displays are shown. * Self check displays and items are subject to the models. Firmware : Display Target name and version information. IF Target name: JH9_PJ, Version: 1.00 =>...
Page 92
service mode. 2. During Version Check, the following displays are shown. * Version check displays and items are subject to the models. (1) MAIN MPU : Version information of microprocessor. Series name and software program version (000_000). (2) EEPROM : Version information of Memory data in EEPROM : Display 1 byte data.
During Status Check, the following displays are shown. * Status check displays and items are subject to the models. (1) MAIN : Main source information : Display RF position number (0 - 999) on the main screen, or Input Source (EXT1/2/3/HDMI etc.) (2) MAIN FORMAT : Display Video format information.
Page 94
appeared in forced when turning the (This function is ignored main power ON when D6 is set to 1.) D6 (bit6) Enable mode that TV On will be Enable Disable appeared in forced when turning the main power ON D5 (bit5) FRONT Key Disable Enable...
forced when turning the main power ON D1 (bit1) ~ Forced picture mode 0 [dec]: Dynamic D0 (bit0) 1 [dec]: Standard 2 [dec]: Mild 3 [dec]: Movie LED Indications The LEDs on the TV (at the bottom of the TV) indicate the TV's status, as described below. Red ON (solid) and Green OFF = The TV power cord is plugged in, but TV is in Standby.
Page 96
TECHNICAL BULLETIN File Name Title issuing date...
PANEL IDENTIFICATION Panel Identification If the several panels are alternatively used in the same model without amending the model name, the identification marking will be shown at the last digit of the set serial number on the specification label on the back cover. In servicing, do not alter the panel because several setting and parts are different.
PARTS LIST Precaution WARNING: BEFORE SERVICING THIS CHASSIS, READ THE "SAFETY PRECAUTION" "PRODUCT SAFETY NOTICE". CAUTION: The international hazard symbols " " in the schematic diagram and the parts list designate components which have special characteristics important for safety and should be replaced only with types identical to those in the original circuit or specified in the parts list.
Page 100
PARTS LIST ↓Select Block : Search 1 / 1 Jump Page : Jump Location : Search Parts No. :...
Page 136
PARTS LIST U04A LED (PE0721) Block : Block Location Parts No. Description U04A LED (PE0721) U04A 75014898 PC BOARD ASSY, PE0721A1, LED U04A LED (PE0721) CB04 76100104 CAPACITOR, CERAMIC CHIP, 25V F 0.1UF Z U04A LED (PE0721) DB01 75009054 DIODE, LED, SML-020MLT T86 U04A LED (PE0721) DB02 75009054 DIODE, LED, SML-020MLT T86...
Page 137
PARTS LIST U04B RMT (PE0721) Block : Search 1 / 1 Jump Page : Jump Location : Search Parts No. : Block Location Parts No. Description U04B RMT (PE0721) U04B 75014899 PC BOARD ASSY, PE0721A2, RMT U04B RMT (PE0721) CB02 76619102 CAPACITOR, ELECTROLYTIC CHIP, 16V 47UF M U04B RMT (PE0721) CB03...
Page 138
PARTS LIST Miscellaneous Block : Search 1 / 1 Jump Page : Jump Location : Search Parts No. : Block Location Parts No. Description Miscellaneous B001A 75014883 LCD PANEL, LTA400HA11 Miscellaneous H001 75016490 TUNER ANALOG FRONT-END, TAEA-G059D Miscellaneous MZ01A 75016492 WIRE HARNESS LVDS HARNESS A9123882, A9123882 Miscellaneous P801 23372297 POWER CORD, CEE...
Page 139
PARTS LIST Accessory Block : Search 1 / 1 Jump Page : Jump Location : Search Parts No. : Block Location Parts No. Description Accessory Y101N 75016494 MANUAL, NORDIC Accessory Y102E 75016495 MANUAL, E EURO Accessory Y103 75016497 MANUAL GOST CERT SHEET, GOST CERT SHEET Accessory Y104 75010400 WARRANTY CARD, RUSSIAN...
Page 140
PARTS LIST Cabinet Block : Search 1 / 1 Jump Page : Jump Location : Search Parts No. : Block Location Parts No. Description Cabinet A201S 75016536 FRONT BEZEL ASSY, FOR SERVICE Cabinet A315 75014841 PIECE, C COVER ASSY Cabinet A342 75011097 BUTTON ASSY, POWER Cabinet...
Page 141
PARTS LIST Packing Block : Search 1 / 1 Jump Page : Jump Location : Search Parts No. : Block Location Parts No. Description Packing A701A 75016491 CARTON CASE TTCE, CASE TTCE Packing A702A 75016297 PAD, TOP PACKING Packing A702B 75016298 PAD, BOTTOM PACKING...
FUNCTION AND OPERATION Tuning the Television for the First Time Before switching on the television, put your decoder and media recorder, if applicable, to Standby. To set up the television, use the buttons on the remote control.
Need help?
Do you have a question about the 40LV655P and is the answer not in the manual?