iHealth View BP7S - Smart Blood Pressure Wrist Monitor Manual
![]()
INTRODUCTION
Thank you for selecting the iHealth View Smart Blood Pressure Wrist Monitor. The iHealth Smart Blood Pressure Wrist Monitor is a fully automatic wrist cuff blood pressure monitor that uses the oscillometric principle to measure your blood pressure and pulse rate. The monitor works with your mobile devices to track and share vital blood pressure data.
PACKAGE CONTENTS
- 1 iHealth View Smart Blood Pressure Wrist Monitor
- 1 User Guide
- 1 Quick Start Guide
- 1 Charging Cable
- 1 Travel Case
INTENDED USE
The iHealth View Smart Blood Pressure Wrist Monitor (Electronic Sphygmomanometer) is intended for use in a professional setting or at home and is a non-invasive blood pressure measurement system. It is designed to measure the systolic and diastolic blood pressures and pulse rate of an adult individual by using a technique in which an inflatable cuff is wrapped around the wrist. The measurement range of the standard cuff circumference is 5.3" to 8.7"(13.5cm-22cm).
Note: Consult your physician for proper interpretation of blood pressure results.
CONTRAINDICATION
It is not recommended for people with serious arrhythmia to use this Smart Blood Pressure Wrist Monitor.
GENERAL SAFETY AND PRECAUTIONS
- Read all of the information in the User Guide and other provided instructions before operating the unit.
- Consult your physician for any of the following situations:
- The application of the cuff over a wound or inflamed area.
- The application of the cuff on any limb with intravascular access or therapy, or an arteriovenous (A-V) shunt.
- The application of the cuff on the arm on the side of a mastectomy.
- Simultaneous use with other medical monitoring equipment on the same limb.
- The blood circulation of the user needs to be checked.
- Do not use this product in a moving vehicle as this may result in inaccurate measurements.
- Blood pressure measurements determined by this product are equivalent to those obtained by professional healthcare practitioners using the cuff/stethoscope auscultation method within the limits prescribed by the American National Standard, Electronic or Automated Sphygmomanometer. This device is also clinically validated according to the 2010 Protocol of the European Society of Hypertension (ESH 2010).
- If an Irregular Heartbeat (IHB) is detected during the measurement procedure, the IHB symbol will be displayed in the "iHealth MyVitals" APP. Under this condition, the Smart Blood Pressure Wrist Monitor can keep functioning, but the results may be inaccurate. Please consult your physician for accurate assessment. The IHB symbol will be displayed under 2 conditions:
- The coefficient of variation (CV) of pulse period >25%.
- The difference of adjacent pulse period is ≥0.14s and more than 53 percent of the total number of pulses readings falls within this definition.
- Please do not use any cuff other than that supplied by the manufacturer as this may result in inaccurate measurements.
- For information regarding potential electromagnetic or other interference between the blood pressure monitor and other devices together with advice regarding avoidance of such interference, please see ELECTROMAGNETIC COMPATIBILITY INFORMATION. It is suggested that the blood pressure monitor should be operated at least 10 meters away from electric or wireless devices (e.g. routers, microwave oven, etc.)
- If the blood pressure measurement (systolic or diastolic) is outside the rated range specified in part SPECIFICATIONS, the monitor will immediately display a technical alarm on the screen. In this case, repeat the measurement ensuring that the proper measurement procedures are followed and/or consult with your medical professional. The technical alarm is preset in the factory and cannot be adjusted or inactivated. This technical alarm is assigned as low priority according to IEC 60601-1-8. The technical alarm does not need to be reset.
- This device requires a medical AC adapter with an output of DC 5.0V that complies with IEC 60601-1/UL 60601-1 and IEC 60601-1-2/EN 60601-1-2 such as ASP5-05010002JU (input: 100-240V, 50/60Hz, 200mA; output: DC 5V, 1.0A). Please note that the monitor jack size is USB mini B. The USB jack should be used for charging only.
This Monitor is designed for adults and should never be used on infants, young children, pregnant or pre-eclamptic patients. Consult your physician before use on children.
This product might not meet its performance specifications if stored or used outside the specified temperature and humidity ranges.
Please do not share the cuff with any infectious person to avoid cross-infection.
PARTS AND DISPLAY INDICATORS
![iHealth - View BP7S - PARTS AND DISPLAY INDICATORS PARTS AND DISPLAY INDICATORS]()
SET UP REQUIREMENTS
Compatible with iPhone 4s+, iPod Touch 5, iPad 3+, iPad Mini+, iPad Air+ and select Android phones. Requires iOS version 7.0+ and Android version 4.0+. For a complete list of compatible devices, visit our support page at www.ihealthlabs.eu/support.
SET UP PROCEDURES
Download the Free iHealth MyVitals App
Prior to first use, download and install "iHealth MyVitals" from the App Store or Google Play Store. Follow the on-screen instructions to register and set up your personal account.
![www.apple.com]()
![play.google.com]()
Access the iHealth Cloud Account
Your iHealth account also gives you access to the free and secure iHealth cloud service. Go to www.ihealthlabs.eu and sign in with the same account.
Charge Battery before First Use
Connect the monitor to a USB port using the charging cable provided until the charging indicator
light green and
indicator steady.
BODY POSTURE DURING MEASUREMENT
Blood pressure can be affected by the position of the cuff and your physiologic condition. It is very important that the cuff is positioned at your heart level during blood pressure measurements.
- Sit comfortably with your feet flat on the floor without crossing your legs. Stay still during measurement. Do not move your wrist, body, or the monitor.
- Place your hand palm-side up in front of you and leave 1-2cm between the monitor and the bottom of your palm. If the monitor is correctly placed, iHealth logo will be facing upright.
![]()
- The center of the cuff should be at your heart level.
![]()
- It is advised to place the monitor's travel case under your arm for support and to keep your arm at optimal height for measurement.
TAKING YOUR BLOOD PRESSURE READING
- Apply the cuff or press the START/STOP button, the monitor will activate and begin to detect your wrist position.
- Adjust the height of your wrist, the monitor will detect your wrist position and the measurement will start ONLY when the correct position is detected. When the position is correct, press "START/STOP" button again to start measurement.
- Then the cuff will be slowly inflated. The blood pressure and pulse will be measured during inflation. Inflation will stop as soon as the blood pressure and pulse rate have been calculated and displayed on the screen. The result will be automatically stored in the memory, and all results will be uploaded to the App automatically upon the next successful Bluetooth connection.
SYNC TIME AND RESULTS VIA BLUETOOTH
Connect to iOS Device via Bluetooth
- Launch the iHealth MyVitals App from your iOS device.
- Enable Bluetooth on your iOS device: Slide gently upward the iPhone screen from
to open the Control Center, and click on the ![]()
- Once the monitor is off, Press "START/STOP" button for 2 seconds untilBluetooth indicator begins flashing -- when a successful connection has been established, the Bluetooth indicator light will stop flashing.
- When sync is processing, the sync indicator flash
and
, when sync is finished, the sync indicator lights up ![]()
Connect to Android Device via Bluetooth
- Press the START/STOP button for 2 seconds, the Bluetooth indicator will begin flashing.
- Enable the Bluetooth on your Android Device.
- When using the monitor for the first time, you should pair the monitor to the Android device. Go into your device's setting to pair it with your Android device. Check the Bluetooth menu for the model name of your monitor (BP7SXXX) to appear, and then select it to pair. This may take up to 30 seconds and your monitor's Bluetooth indicator will light up when a connection has been established.
- Launch the "iHealth MyVitals" app to sync with your monitor.
- When sync is processing, the sync indicator flash
and
, when sync is finished, the sync indicator lights up ![]()
- Please repeat these steps when you switch to another Android device with the monitor.
Remember to:
- Make sure your wrist size is within cuff circumference; see the range in "SPECIFICATIONS"
- Measure on the same wrist each time.
- Stay still and calm for one to one and half minutes before taking a blood pressure measurement. Prolonged over-inflation of the bladder may cause bruises of your wrist.
- Keep the cuff clean. Cleaning the cuff after every 200 times of usage is recommended. If the cuff becomes dirty, clean it with a moistened cloth. Do not rinse the monitor or cuff with running water.
- Press the "START/STOP" button at any time to interrupt a measurement.
Note: Physical activity, eating, drinking, smoking, excitement, stress, and many other factors influence blood pressure results.
SPECIFICATIONS
- Product name: iHealth View Smart Blood Pressure Wrist Monitor
- Model: BP7S
- Classification: Internally powered; Type BF applied part; IP22, No AP or APG; Continuous operation
- Machine size: approx. 2.8"×2.9"×0.7" (72mm×74mm×17.6mm)
- Cuff circumference: 5.3"- 8.7" (13.5cm-22cm)
- Weight: approx. 4.2oz(120g)(including cuff)
- Power: DC:5.0V
1.0A, Battery: 1*3.7V
Li-ion 400mAh - Measurement range:
Cuff pressure: 0-300 mmHg
Systolic: 60-260 mmHg
Diastolic: 40-199 mmHg
Pulse rate: 40-180 beats/minute - Accuracy:
Pressure: ±3 mmHg
Pulse rate: ±5% - Environmental temperature for operation: 10°C-40°C(50°F -104°F)
- Environmental humidity for operation: ≤85%RH
- Environmental temperature for storage and transport:-20°C-55°C(-4°F-131°F)
- Environmental humidity for storage and transport: ≤85%RH
- Environmental pressure: 80kPa-105kPa
- Battery life: more than 80 measurements on a full charge
- The blood pressure measurement system includes accessories: pump, valve, cuff, and sensor.
Note: These specifications are subject to change without notice.
BATTERY HANDLING AND USAGE
- The battery charge will be displayed on the LED screen when the monitor is active. And when the monitor is connected to the "iHealth MyVitals" APP, the battery charge will be displayed in the APP. If the power is less than 25%, please charge the battery. The monitor will not work until the battery has enough power.
- When the monitor needs charging, please connect the monitor to a power source. The monitor can work normally while charging.
- You should charge the battery when the battery is less than 25% charged. Overcharging the battery may reduce its lifetime.
- When in charging mode, the charging status will be displayed on the LED screen. See the table below for details.
Monitor Status | Status Indicator |
Charging | symbol green | symbol rolling |
Fully charged | symbol green | symbol steady |
Low battery | symbol flashing | (for a few seconds) |
Do not change the battery. If the battery can no longer be charged, please contact Customer Service.
Overcharging the battery may reduce its lifetime.
Lithium battery replacement by inadequately trained personnel could result in a hazard such as a fire or explosion.
Do not plug or unplug the power cord into the electrical outlet with wet hands. If the AC adapter is abnormal, please change the adapter.
Do not pull out the adapter when you are using the monitor.
Do not use any other type of AC adapter as it may harm the monitor.
Note: Battery life and charge cycles vary by use and settings.
TROUBLESHOOTING
PROBLEM | POSSIBLE CAUSE | SOLUTION |
Low Battery | Battery do not have enough power | Charge the battery |
LED display reads "Er0" | Pressure system is unstable before measurement | Retest, make sure not to move your arm or the monitor |
LED display reads "Er1" | Fail to detect systolic pressure |
LED display reads "Er2" | Fail to detect diastolic pressure |
LED display reads "Er3" | Pneumatic system blocked or cuff is too tight during inflation | Apply the cuff correctly and try again |
LED display reads "Er4" | Pneumatic system leakage or cuff is too loose during inflation |
LED display reads "Er5" | Cuff pressure above 300mmHg | Measure again after five minutes. If the monitor is still abnormal, please contact the local distributor or the factory. |
LED display reads "Er6" | More than 160 seconds with cuff pressure above 15 mmHg |
LED display reads "Er7" | memory accessing error |
LED display reads "Er8" | Device parameter checking error |
LED display reads "ErA" | Pressure sensor parameter error |
LED display reads " Er " | Bluetooth communicate error | Connect the mobile device correctly and try again, If the monitor is still abnormal, please contact the local distributor or the factory. |
LED display reads an abnormal result | The cuff position was not correct or it was not properly tightened | Review the cuff application instructions and retest |
Body posture was not correct during testing | Review body posture instructions and retest |
Speaking, moving arm or body, being angry, excited or nervous during test | Retest when calm; avoid speaking or movement during the test |
Bluetooth connection unstable | Bluetooth connection unsuccessful, monitor is abnormal, or strong electromagnetic interference is present | Reset iOS/Android device. Reset monitor by pressing the START/STOP button and holding for about 10 seconds. Make sure the monitor and iOS/Android device are away from other electrical equipment. Please see GENERAL SAFETY AND PRECAUTIONS |
No response when you press button | Incorrect operation or strong electromagnetic interference | Press the START/STOP button and hold for about 10 seconds to reset the device. |
CARE AND MAINTENANCE
- If this monitor is stored near freezing temperatures, allow it to return to room temperature before use.
- If the monitor is not used for a long time, please be sure to fully charge it every month.
- No monitor component needs to be maintained by the user. The circuit diagrams, component part lists, descriptions, calibration instructions, or other information which will assist the user's appropriately qualified technical personnel to repair those parts of the equipment which are designated for repair can be supplied by the iHealth technical department.
- Clean the monitor with a dry, soft cloth or a moistened and well wrung soft cloth using water, diluted disinfectant alcohol, or diluted detergent.
- The monitor can maintain the safety and performance characteristics for a minimum of 10,000 measurements or three years of usage, and the cuff integrity is maintained after 1,000 open close cycles.
- The battery can maintain the performance characteristics for a minimum of 300 charge cycles.
- It is recommended that if the cuff is used in a hospital or a clinic, it be disinfected twice a week. Wipe the inner side (the side that contacts skin) of the cuff with a soft cloth lightly moistened with Ethyl alcohol (75-90%). Then air dry the cuff.
Do not drop this monitor or subject it to strong impact.
Avoid high temperature and direct sunlight. Do not immerse the monitor in water as this will result in damage to the monitor.
Do not attempt to disassemble this monitor.
Battery replacement should only be performed by a qualified iHealth technician. To do otherwise will void your warranty and possibly damage your unit.
Cuff replacement should only be performed by a qualified iHealth technician. To do otherwise will possibly damage your unit.
- It is recommended that product performance be checked every 2 years or after each repair. Please contact the iHealth Customer Service Center to do so.
![]()
Documents / Resources
References
Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download iHealth View BP7S - Smart Blood Pressure Wrist Monitor Manual
Need help?
Do you have a question about the View BP7S and is the answer not in the manual?