Under Test
Under Test
Figure 1
Figure 2
CH
Frequency
Voltage at TP3
CH2
520.000 MHz
20.8-21.2 volts
CH3
1000.000 MHz
9.0-13.0 volts
CH4
1300.000 MHz
21.8-22.2 volts
455 kHz NFM Discriminator Coil Alignment
Table 2
Control Setting
Test Instrument Connection
Adjust
Result
OFFNOLUME control: ON.
Connect the signal generator to
T9
Set the signal generator lre-
SQUELCH control: CCW.
the ANT jack and the OC
quency to 520 MHz, 100
~V
Select channel 2.
SSVM to TP2.
output (no mod.) and adjust T9
See Figure 4.
lor 4.0!8· 3 volts on the OC
SSVM.
10.7 MHz WFM Discriminator Coil Alignment
Control Setting
Test Instrument Connection
Adjust
Result
OFFNOLUME controt ON.
Connect the signal generator to
T5
Set the signal generator tre-
SQUELCH control: CCW.
the ANT jack and the OC
quency to 520 MHz, 100
~V
Select channel 5.
SSVM to TP1.
output (no mod.) and adjust T4
See Figure 4.
lor 4.0!8·3 volts on the OC
SSVM.
AnI.
Jack
TPI or TP2
Unit
UnderTest
DGSSVM
Signal
Generator
Figure 4